The Development of LVI Tester for WInding Deformation Measurement in Power Transformers (변압기의 권선변형 검증을 위한 LVI 시험기 개발)

  • 조국희;김광화;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF

An Application Study of System Stabilizing Control Scheme by Switching-over Control (한전계통에 대한 안정화제어 방안의 적용연구)

  • Kim, Tae-Kyun;Cho, Kang-Wook;Kim, Yong-Hak;Kim, Il-Dong;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1109-1111
    • /
    • 1997
  • The purpose of this paper is to analyze the effects of switching-over control for power system stabilization. Switching-over control is applied to western part of korea electric power system to improve transient stability and short-circuit capacity. It's effectiveness is demonstrated in terms of fault current level and critical clearing time which is quantitative evaluation means of transient stability. The effect of generator tripping for power system stabilization is also presented.

  • PDF

A Study on the Advanced Protective Coordination Schemes of Distribution System Considering Distributed Generations (분산전원을 고려한 배전계통의 개선된 보호협조 방안 연구)

  • Choi, Dong-Man;Choi, Joon-Ho;Moon, Seung-Il;Kim, Jae-Chul;Moon, Chae-Joo;Kim, Il-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.701-703
    • /
    • 2005
  • Recently, There has been growing interest in Distributed Generations with high-energy efficiency due to the Increasing energy consumption and environmental pollution problems. but an insertion of Distributed Generations to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to Sukumar M[l] proposal schemes and identity the faulted section performing short-circuit analysis by MATLAB program to distribution systems interconnected a large number of distributed generations.

  • PDF

Influence of Diameter of Puffer Cylinder on Thermal Interruption Capability of EHV GCB (파퍼실린더 직경이 초고압 GCB의 열적 차단성능에 미치는 영향)

  • Oh, Y.H.;Song, K.D.;Choi, Y.K.;Lee, Byeong-Yun;Park, K.Y.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.37-39
    • /
    • 1998
  • This paper presents the pressure-rise of the puffer cylinder in a model gas circuit breaker and the analyzed results of thermal interruption capability in SLF(short line fault) to the diameter of the puffer cylinder. This paper can be applied to the design of the EHV interrupter.

  • PDF

Influence of polymer coating on SFCL recovery under load

  • Gorbunova, D.A.;Kumarov, D.R.;Scherbakov, V.I.;Sim, Kideok;Hwang, Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.44-47
    • /
    • 2019
  • This paper is a study of recovery under load process of superconducting fault current limiter (SFCL). SFCL consists of five parallel-connected high-temperature superconductor (HTS) tapes additionally stabilized by stainless tape. Previously, HTS was heated by current pulse to simulate a short circuit in a power grid. During the cooling period, the current amplitude decreased to 23% or less of HTS critical current value, which is the simulation of network re-switching. When HTS with a polymer coating is cooled, temperature gradient on thermal insulation layer occurs, that prevents a boiling crisis and improves the heat sink into liquid nitrogen. Two samples are coated with a 30 ㎛ and 50 ㎛ polylactide (PLA) layers, reference sample has no polymer coating on it. Samples with a polymer coating show 3-5 times faster cooling than the reference one.

Modifying the aggregated wind farm model with a controller

  • Badr, Mohammed. A.;Atallah, Ahmed. M.;Bayoumi, Mona A.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.133-142
    • /
    • 2015
  • A large wind farm can be simplified by the aggregated wind farm models for load flow, steady and transient stability studies. When a fault (such as a short circuit) happens in a large wind farm, some of wind turbines trip while others do not. This paper is to design a controller to modify the aggregated wind farm model in the case of one or more unit removed or added from the complete model. This is without stopping the simulation process during performing the steady state and transient analysis of the whole system. This controller can modulate the status of the wind turbines in the aggregated model in a given farm according to any change in this farm. By this controller, we save effort and time to change the status of wind turbines in the aggregated model. The proposed wind farm is composed of some smaller farms of permanent magnet synchronous generators (PMSGs) and others of squirrel cage induction generators (SCIGs).

PROSET2000 : An Integrated Computer Program for Power Transmission System Protection (PROSET2000 : 송전계통 보호 전산종합 프로그램 개발)

  • Kim, Yeong-Il;Lee, Seung-Jae;Choe, Myeon-Song;Gang, Sang-Hui;Kim, Ho-Pyo;Lee, Un-Hui;Choe, Hong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.538-544
    • /
    • 1999
  • One of the most important requirements for the development of computerized relay setting system is its openness to abbommodate the various changes like new panel additions. This paper describes the relay settein-coordination system(PROSET2000), which has an open system architecture and adopts the dbject oriented programming paradigm. Its main features include the intelligent fault type identification, automatic running of the short circuit analysis, ren-time rulebase modification, automatic documentation, ect.

  • PDF

An Integrated Setting-Coordination Program for Protective Relay of Transmission Systems (송전계통 보호계전기 정정협조 종합프로그램)

  • Kim, Young-Il;Lee, Seung-Jae;Choi, Myeon-Song;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.229-231
    • /
    • 1998
  • One of the most important requirements for the development of computerized relay setting system is its openness to accommodate the various changes like new panel additions. This paper describes the relay setting system(PROSET2000), which has an open system architecture and adopts the object oriented programming paradigm. Its main features include the intelligent fault type identification, automatic running of the short circuit analysis, run-time rulebase modification, automatic documentation, etc.

  • PDF

A Study on Micom Algorithm Design for Prevention of Serial Parallel Arc Accident (직병렬아크사고 예방을 위한 마이컴 알고리즘 설계에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Choi, Shin-Hyeong;Jung, Do-Young;Kim, Dae-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.9-11
    • /
    • 2018
  • This paper studies on the development of an electric fire prevention system with the detection and alarm in case of parallel arc fault occurrence in low voltage distribution lines. The proposed detector has the characteristics of high speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. The line voltage is always feedback, and when an arc or a spark occurs, these are detected by the microcomputer. In addition, we design and develop algorithms using high speed and high precision microcomputer. A new conceptual control technique is adopted that RCD cuts-off by forming a forced short circuit between the phase voltage and ground in the event of an electrical accident. Some experimental tests of the proposed system also confirm practicality and the validity of the analytical results.

  • PDF

Analysis and Design of FRT Detection System Using PMU (PMU를 사용한 FRT 검출시스템 설계 및 분석)

  • Kwon, Dae-Yun;Moon, Chae-Joo;Jeong, Moon-Seon;Yoo, Do-Kyeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.643-652
    • /
    • 2021
  • Accidents or faults in the transmission and distribution system are never completely avoidable, and short-circuit and earth faults are occurs despite the efforts of the TSO and DSO. Recently, the connection to the transmission and distribution system of large-capacity new and renewable distributed power has increased rapidly and has various effects on the operation of the system. In order to minimize this, connection standards such as FRT (Fault-Ride-Through) have been established to provide wind turbines or solar inverters. In the event of a major faults of the power system, the operation support shall be provided so that the operator can stably operate the system by smoothly performing connection maintenance or rapid system separation. In this paper, in order to appropriately determine whether the FRT condition, which is the grid connection criterion for a representative DERs, is sufficient, a detection system using a PMU (Phasor Measurement Unit) that measures a synchro-phasors was designed and deployment and a system accident due to a generator step-out to analyze and evaluate the proposed system based on the case.