• Title/Summary/Keyword: Short distance

Search Result 1,228, Processing Time 0.025 seconds

Return of spontaneous circulation rate according to dispatch distance in out-of-hospital cardiac arrest (출동 거리에 따른 병원 전 심장정지 환자의 자발순환회복률 분석)

  • Kim, Jong-Ho;Jeon, Youn-Chel;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.2
    • /
    • pp.51-61
    • /
    • 2017
  • Purpose: This study measured return of spontaneous circulation (ROSC) in relation to dispatch distance in patients with out-of-hospital cardiac arrest. Methods: Of 2,347 out-of-hospital cardiac arrest patients transported by emergency medical technicians in J Province between January 1 and December 31, 2015, those under age 18, those with reserved resuscitation, and those with traumatic cardiac arrest, leaving 855 patients in the study sample. ROSC was compared between those with dispatch distance ${\leq}4km$ (short dispatch distance, 465 patients) and those with dispatch distance >4 km (long dispatch distance, 390 patients). Results: The mean was 2.17 km in the short dispatch group and 9.87 km in the long dispatch group (p=.000). Mean distance from was 6.49 km and 13.39 km in the two groups, respectively (p=.000). ROSC differed significantly between the short and long dispatch distance groups (7.1% for short dispatch distance, 3.6% for long dispatch distance, p=.025). The length of time from to cardiopulmonary resuscitation also differed significantly between the short and long dispatch distance groups (8.77 minutes and 14.63 minutes, respectively, p=.000). Conclusion: ROSC was lower in areas of long dispatch distance compared to those of short dispatch distance. We expect this was most likely due to differences in response time by age and dispatch distance to the scene of cardiac arrest. However, no significant differences were found between the groups in the factors affecting ROSC.

A Method of Effective Vibration Reduction for Positioning Systems Undergoing Frequent Short-distance Movement (단거리 이동을 반복하는 위치결정장치를 위한 효율적인 진동저감 방법)

  • Hong, Seong-Wook;Bae, Gyu-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.421-428
    • /
    • 2013
  • The current vibration reduction methods for positioning systems lead to either complicated motion or the need for additional hardware when the positioning systems carry out frequent short-distance movements. This paper proposes a simple yet efficient vibration reduction method for positioning systems subjected to frequent short-distance movements. The essence of the proposed method is the trapezoidal or triangular velocity profiles, whose acceleration/deceleration rates are designed to be related to the natural frequency of concern. The combined use of the proposed method and the input shaping method is also proposed for the possible application to multi-mode systems. Experiments are performed to validate the proposed method. The simulation and experiments prove that the proposed method is of great use for residual vibration reduction in positioning systems subjected to frequent short-distance movement.

Comparative Analysis on Muscle Function and EMG of Trunk and Lower Extremity in Short and Long Distance Athlete (육상 단거리 선수와 장거리 선수의 체간과 하지의 근기능 및 근전도 비교 분석)

  • Jung, Jae-Hu;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The purpose of this study was to compare and analyze muscle function and EMG of the trunk and the lower extremity in short and long distance athletes and in order to determine difference in peak torque per unit weight, muscle power per unit weight, endurance ratio, and %MVIC classified by muscle. For that purpose, isokinetic muscle function tests for waist, knee, and ankle joints and EMG measurements for the trunk and the lower extremity muscle with running motion were conducted for 7 short and long distance high school athletes respectively. The study over muscle function of waist, knee, and ankle joints indicates that peak torque per unit weight of short distance athletes is higher than that of long distance athletes in extension and flexion of waist joint, plantar flexion of right ankle joint, and dorsi flexion of left ankle joint. In case of the muscle power per unit weight of short distance athletes is also higher than long distance athletes in waist, knee, and ankle joints. No difference in endurance ratio of waist, knee, and ankle joints between the two groups was founded. The results of the test over EMG of the trunk and the lower extremity show that %MVIC of erector spinae, rectus femoris, vastus medialis, vastus lateralis, and tibialis anterior is higher than that of long distance athletes in support phase. The above results proved to be the same in flight phase except for %MVIC of medial gastrocnemius. In other words, %MVIC of medial gastrocnemius for short distance athletes turned out to be higher than that of long distance athletes in flight phase.

Effects of Shoe Heel Height on Walking Velocity and Electromyographic Activities of Lower Extremity Muscles During Short- and Long-Distance Walking in Young Females (젊은 여성에서 단거리 및 장거리 보행 시 신발 뒤굽 높이가 보행 속도와 다리 근육의 근활성도에 미치는 영향)

  • Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.16-23
    • /
    • 2019
  • Background: High-heeled shoes can change spinal alignment and feet movement, which leads to muscle fatigue and discomfort in lumbopelvic region, legs, and feet while walking. Objects: This study aimed to identify the effects of different shoe heel heights on the walking velocity and electromyographic (EMG) activities of the lower leg muscles during short- and long-distance walking in young females. Methods: Fifteen young females were recruited in this study. The experiments were performed with the following two different shoe heel heights: 0 cm and 7 cm. All participants underwent an electromyographic procedure to measure the activities and fatigue levels of the tibialis anterior (TA), medial gastrocnemius (MG), rectus femoris (RF), and hamstring muscles with each heel height during both short- and long-distance walking. The walking velocities were measured using the short-distance (10-m walk) and long-distance (6-min walk) walking tests. Results: Significant interaction effects were found between heel height and walking distance conditions for the EMG activities and fatigue levels of TA and MG muscles, and walking velocity (p<.05). The walking velocity and activities of the TA, MG, and RF muscles appeared to be significantly different between the 0 cm and 7 cm heel heights during both short- and long-distance walking (p<.05). Significant difference in the fatigue level of the MG muscle were found between the 0 cm and 7 cm heel heights during long-distance walking. In addition, walking velocity and the fatigue level of the MG muscle at the 7 cm heel height revealed significant differences in the comparison of short- and long-distance walking (p<.05). Conclusion: These findings indicate that higher shoe heel height leads to a decrease in the walking velocity and an increase in the activity and fatigue level of the lower leg muscles, particularly during long-distance walking.

High-Accuracy Coastdown Test Method by Distance-Time Measurement: II. Development of a Short Distance Method and its Evaluation (거리·시간 측정에 의한 고정도 타행시험법: II. 단거리 방법의 개발 및 시험)

  • Hur, N.G.;Ahn, I.K.;Petrushov, V.A.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.1-8
    • /
    • 1995
  • In the companion paper of the present paper, a coast down test method to determine the resistance forces on running vehicle based on the distance-time measurement was explained along with the suggestions to improve its accuracy and testing methodology. In the present paper some of the suggestions discussed previously are implemented and actually road tested to see the applicability of the improved method(short distance method) in the field. From the results. it is shown that the short distance method which requires only 600m long proving ground road gives at least comparable results on the accuracy compared to the original S-t method which requires 2000m. It is hoped that the present method be further refiend to give more accurate results.

  • PDF

Estimate of Flashover Position from E-field Calculation along Electrode Gap Distance (진공인터럽터 극간 랩거리 조정에 따른 각 부위의 전계값 계산을 통한 진공인터럽터 내부 절연파괴부위 예측)

  • Yoon, Jae-Hun;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.23-23
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, various models that short and long gap distance were used to analyze E field of each model. Calculation value was estimated of flashover position. As a result, short and long gap distance that vacuum interrupter inner between move electrode and fix electrode not coincided flashover position of each model. short gap distance estimated flashover position at electrode edge. but long gap distance model confirmed $E_{max}$ value at center shield. in this paper was compared electric field value. and estimated of flashover position from electric field calculation.

  • PDF

The Impact of Cross-Cultural Differences on Human Resource Management in Korean-Invested Enterprises in China

  • Li, Hao;Li, Yu
    • Journal of Korea Trade
    • /
    • v.25 no.2
    • /
    • pp.46-57
    • /
    • 2021
  • Purpose - In terms of human resource management, many Korean enterprises in China have experienced problems such as frequent resignations of Chinese employees and labor disputes. This can be mainly attributed to the fact that Chinese employees are not consistent with Korean vertical management methods, which is closely related to the national culture theory proposed by Hofstede, specifically the dimension of power distance and long- versus short-term orientation (LTO). Therefore, this research aims to investigate cultural differences between Korea and China from these two dimensions, and the impact on the human resource management of Korean-invested enterprises in China. Design/methodology - This research first utilizes the latest data (Wave 7) of the World Values Survey (WVS) to verify the difference in power distance and long- versus short-term orientation between Korean and Chinese cultures using responses from Korea and China, and then uses case analysis to analyze the impact of this cultural difference on the human resource management of Korean enterprises in China. Findings - Our main findings can be summarized as follows. Korea and China have significant differences in power distance and long- versus short-term orientation. In terms of power distance, Korean respondents show higher power distance compared to Chinese respondents. In the dimension of long- versus short-term orientation, it was found that Chinese respondents showed a shorter-term orientation, whereas Korean respondents showed a longer-term orientation. Originality/value - Previous studies put focus on the power distance and individualism-collectivism dimensions to explain cultural differences between Korea and China, and generated contradictory results. This research further confirms the cultural differences between Korea and China from the dimensions of power distance and long-versus short-term orientation using secondary data. The comparative studies from this perspective have long been underexplored and lack empirical confirmation.

Study on the Design of Asymmetric Lighting with Uniform Illumination Over a Large Area at Short Distance (단거리 조사 시 넓은 면적에 균일한 조명도를 가지는 비대칭 조명 광학계 설계 연구)

  • Kang, Dong-Hwa;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.4
    • /
    • pp.183-190
    • /
    • 2020
  • In this paper, the illuminating optics of asymmetric light distribution was studied, which allowed the light distribution to be uniform even for short-range irradiation on a wide illumination area. In the case of a light installed at a short distance, the light is not diffused enough because of the short irradiation distance. For this reason, it is difficult to satisfy uniformity of illumination. In addition, lighting design for asymmetric distribution is required because the lighting device is installed tilted, for visibility. Therefore, the design of lighting systems with asymmetric light distribution could achieve uniform illumination of the target surface even under short-distance irradiation. This was then applied to the license lamp, a lighting system featuring short light irradiation distance, to confirm that it satisfies the legal standards.

Combining Distributed Word Representation and Document Distance for Short Text Document Clustering

  • Kongwudhikunakorn, Supavit;Waiyamai, Kitsana
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.277-300
    • /
    • 2020
  • This paper presents a method for clustering short text documents, such as news headlines, social media statuses, or instant messages. Due to the characteristics of these documents, which are usually short and sparse, an appropriate technique is required to discover hidden knowledge. The objective of this paper is to identify the combination of document representation, document distance, and document clustering that yields the best clustering quality. Document representations are expanded by external knowledge sources represented by a Distributed Representation. To cluster documents, a K-means partitioning-based clustering technique is applied, where the similarities of documents are measured by word mover's distance. To validate the effectiveness of the proposed method, experiments were conducted to compare the clustering quality against several leading methods. The proposed method produced clusters of documents that resulted in higher precision, recall, F1-score, and adjusted Rand index for both real-world and standard data sets. Furthermore, manual inspection of the clustering results was conducted to observe the efficacy of the proposed method. The topics of each document cluster are undoubtedly reflected by members in the cluster.

A Study on Implementation and Performance Measurement of a Short Distance Wireless Transceiver System with Microprocessor (마이크로프로세서를 이용한 근거리 무선 송수신 시스템의 구현과 성능측정에 관한 연구)

  • 차용성;강병권
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.305-308
    • /
    • 2001
  • In this paper, we realized a transceiver system for short distance communication with a commercial RF module working in ISM band and a microprocessor. Also we measured system performance by transmitting baseband data in a building and then we compared the demodulated 긴ta bits with stored data bits in a PC connected with demodulator. The RF module in the experiments works oかy in the bandwidth, 424MHz - 429MHz. with FM mode. The signal level degrades as the distance between transmitter and receiver increases we measured the signal level and bit error in the building of engineering college of our university. we present the measured data with various locations in the building. and the data may be used in design short distance network in a building.

  • PDF