• Title/Summary/Keyword: Short dental procedure

Search Result 29, Processing Time 0.02 seconds

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

Influence of gag reflex on removable prosthetic restoration tolerance according to the patient section of the short form of the Gagging Problem Assessment Questionnaire

  • Yildirim-Bicer, Arzu Zeynep;Akarslan, Zuhre Zafersoy
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.474-482
    • /
    • 2014
  • PURPOSE. To assess removable prosthetic restoration tolerance according to the patient section of the short form of the Gagging Problem Assessment Questionnaire (GPA-pa SF) and the influence of gender, education level and prosthesis type and denture-related mucosal irritation on the GPA-pa SF scores before treatment and over a period of two months after prosthesis insertion. MATERIALS AND METHODS. 130 participants who required removable prosthesis were surveyed with a standard form that included questions regarding age, gender, education level, dental attendance, and prosthetic restoration type. Participants answered the GPA-pa SF before restoration (T0) and 1 day (T1), 2 days (T2), 15 days (T3), 1 month (T4), and 2 months (T5) after prosthesis insertion. RESULTS. Of the 130 participants, 110 participants completed the prosthetic restoration procedure, but only 93 of these were able to use the prosthesis over the two-month period. The mean GPA-pa SF score obtained at T0 was higher than the scores obtained at the other periods in the total of the sample. Significant difference was present between mean scores obtained at T0-T1 and T2-T3 than scores obtained at other periods (P<.05). Female participants and participants with denture-related mucosal irritation had higher GPA-pa SF scores at all time points analysed. Significant difference was present between mean GPA-pa SF scores obtained at T2-T3 than scores obtained at other periods for females and participants with denture-related mucosal irritation (P<.05). Education level and prosthesis type did not significantly influence the GPA-pa SF score at any time point analysed (P>.05). CONCLUSION. GPA-pa SF scores were higher before the restoration procedure began, and decreased over time with the use of prosthesis. Gender and denture-related mucosal irritation affected the GPA-pa SF scores.

Restoration of Upper Anterior Dentition using Customized Anterior Guide Table (Customized Anterior Guide Table을 이용한 상악 전치부 수복증례)

  • Oh, Woo-Shik;Jeong, Seung-Mi;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2003
  • When making crown and bridges on anterior regions, many practitioners consider the esthetics the most. For this reason functional aspect are not considered as much as the esthetics. If the occlusion on the anterior region are not formed correctly, movement of the temporomandibular joint can be disturbed and excessive stress can be occur that pathologic condition can be under lied. On this case presentation will show the importance of the anterior guidance and suggest the appropriate protocol of using customized anterior guide table. A 45years old male had to remake both of the upper central and lateral PFM because of the porcelain fracture. The new PFM crowns were made conventional methods without considering the anterior guidance. After the temporary setting, the patient complained of discomfort and short looking upper anteriors. To solve these problems we had to restore the palatal contour and length of the new crowns by making customized anterior guide table using temporary crowns that contains patient's old anterior guidance. This procedure which is copying the pt's comfortable anterior guidance to the final prosthesis made them to be esthetic and patients to feel comfortable.

Postinsertion Adjustment Procedures of Removable Partial Dentures (가철성 국소의치의 조정)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.384-390
    • /
    • 2013
  • Postinsertion problems tend to be minimized when a sequential insertion procedure is followed. However, problems may occur as the result of one or any combination of comfort, function, esthetics, and phonetic difficulties. Following the insertion of a partial denture, an appointment for review in approximately 7 days should be made for the patient. At the review visit, the patient should be questioned concerning any problems that have been experienced when wearing the denture. A thorough examination should then be carried out of the oral tissues and the denture, in the course of which signs of tissue damage may be observed. A diagnosis is then made of the cause of all the problems revealed in the history and examination procedures. Appropriate treatment should then be applied to resolve these problems.

Minor Orthodontic Treatment Using NiTi Wire Exerting Light Force: Case Reports (약한 힘을 내는 NiTi 와이어를 이용한 부분교정: 증례보고)

  • Hwayeon, An;Seonmi, Kim;Namki, Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.505-513
    • /
    • 2022
  • Minor orthodontic treatment using a thin wire with high elasticity can shorten the treatment period and reduce the load on the anchorage by the application of light force. Since it can be applied immediately without a dental laboratory procedure and does not require the patient's cooperation, it can be clinically useful. The cases reported here have led to positive results in short periods of treatment, using only a segmented straight 0.012 inch NiTi wire and flowable resin to address various locations within the oral cavity, such as the anterior teeth, premolars, and molars.

Survey on Preferences Regarding Rubber Dams in Children, Adolescents and Parents (러버댐에 대한 소아, 청소년 및 보호자에 대한 선호도 조사)

  • Jeong, Hankeul;Lee, Nanyoung;Lee, Sangho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.17-26
    • /
    • 2016
  • The use of a rubber dam is a useful technique for protecting patients and operators, producing good results when treating children and adolescent patients. Despite its many advantages, some children and adolescent patients have negative feelings and sometimes express its discomfort. The purpose of this study was to evaluate the patients' preferences for rubber dam use and the associated factors that may affect it. A survey was conducted targeting patients aged 4-18 years old who visited the pediatric dental clinic, the restorative dental clinic, or the student treatment dental clinic of ${\bigcirc}{\bigcirc}$ University Dental Hospital, and were treated using a rubber dam without sedation. We collected questionnaires through electronic medical records. Most children and adolescent patients showed positive attitudes towards using rubber dams. The group with a short treatment time and the group with past knowledge or experience of rubber dam use showed more positive attitudes towards rubber dams (p < 0.05), while no significant difference was found among factors such as gender, age, procedure, anesthetics, treatment site, and operator (p > 0.05).

APPLICATION OF THERMOFORMED APPLIANCES IN PEDIATRIC DENTISTRY (소아치과 임상에서의 Thermoformed Appliance의 적용)

  • Kim, Shin;Jeong, Tae-Sung;Yang, Chul-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.539-544
    • /
    • 1998
  • Thermoformed appliance, which has been recently introduced for dental usage, is an appliance made of thermoformed sheets and formed with positive or negative pressure under heat. Thermoplastic material is a kind of plastics and can be repeatedly softened by heat. It is classified into hard elastic foil, hard/soft compound foil and soft elastic foil, including BIOPLAST, BIOCRYL, IMPRELON, etc. It has been developed in 1969 and is available in various thickness, shape and color. There are two types of Vacuum former for thermoplastic materials; the pressure type and suction type. The former is much better than the latter for fabrication of various appliances due to its higher pressure. The authors have applied these appliances to some cases - chin cap, active retainer, individual Fluoride tray, mouth protector, bracket transfer mask, bruxism splint(night guard), Essix appliance - by pressure type Vacuum former($Biostar^{(R)}$). The thermoplastic appliances have numerous advantages such as simple procedure, short working time, clean and transparent product, less objectionable taste. But its outstanding advantage would be its excellent biocompatibility bacause it has no monomer and hence no tissue irritation. Although there is some limitations in its usage, it can be used widely for various purposes especaily for pediatric dentistry.

  • PDF

SINUS AUGMENTATION WITH ${\beta}$-TCP (${\beta}$-TCP를 이용한 상악동 점막거상술)

  • Hwang, Kyung-Gyun;Song, Seung-Il;Kim, Sang-Woo;Lee, Sung-Hoon;Kim, Young-Muen;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.428-433
    • /
    • 2004
  • Sinus floor augmentation has been proven an effective treatment procedure to increase bone volume in the posterior edentulous maxilla. Autogenous bone considered to be the best material for reconstructive bone surgery and has been successfully used as a graft material to augment posterior maxilla. However, the collection of autogenous bone required extra risks for morbidity and complaints. So, various bone graft materials included ${\beta}$-tricalcium phosphate(${\beta}$-TCP) has been introduced for replacing the autogenous bone. The objective of this clinical study was to determine the predictability of endosseous implant placed in a maxillary sinus with ${\beta}$-TCP grafting. We performed sinus elevation with ${\beta}$-TCP to install the implant in the 10 maxillary cases. The prosthetic procedure was performed 6-9 months after. The implant-prosthetics was checked about 1 year. We checked the implant and measured the maximum bite force to evaluate the function of the implant. There was not observed the specific problem and complication in dental implant and maxillary sinus in the grafted materials. The maximum bite force was 558N in case of natural tooth, 365N in implant without grafting, 318N in implant with ${\beta}$-TCP grafting. There was no significant difference between with and without sinus grafting on maximum bite force(p>0.05). As though the long term check-up is needed, the grafting of ${\beta}$-TCP as a osteoconductive materials can expand the volume and induce dense new bone formation in maxillary sinus. So, this short-term results support that ${\beta}$-TCP can be a suitable material for sinus augmentation.

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF