• 제목/요약/키워드: Short circuit faults

검색결과 94건 처리시간 0.027초

CMOS VLSI의 IDDQ 테스팅을 위한 ATPG 구현 (Implementation of ATPG for IdDQ testing in CMOS VLSI)

  • 김강철;류진수;한석붕
    • 전자공학회논문지A
    • /
    • 제33A권3호
    • /
    • pp.176-186
    • /
    • 1996
  • As the density of VLSI increases, the conventional logic testing is not sufficient to completely detect the new faults generated in design and fabrication processing. Recently, IDDQ testing becomes very attractive since it can overcome the limitations of logic testing. In this paper, G-ATPG (gyeongsang automatic test pattern genrator) is designed which is able to be adapted to IDDQ testing for combinational CMOS VLSI. In G-ATPG, stuck-at, transistor stuck-on, GOS (gate oxide short)or bridging faults which can occur within priitive gate or XOR is modelled to primitive fault patterns and the concept of a fault-sensitizing gate is used to simulate only gates that need to sensitize the faulty gate because IDDQ test does not require the process of fault propagation. Primitive fault patterns are graded to reduce CPU time for the gates in a circuit whenever a test pattern is generated. the simulation results in bench mark circuits show that CPU time and fault coverage are enhanced more than the conventional ATPG using IDDQ test.

  • PDF

접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구 (A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults)

  • 최정규;곽동걸;이승철;이봉섭;박영직
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

Mitigation of high energy arcing faults in nuclear power plant medium voltage switchgear

  • Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.317-324
    • /
    • 2019
  • A high energy arcing fault event occurred in the medium-voltage (13.8 kV and 4.16 kV) metalclad switchgears in a nuclear power plant not only affecting switchgear but also connected equipment due to the arc energy. The high energy arcing fault also causes a fire that influences the safety function of the unit. Therefore, from the safety point of view, it is necessary to evaluate the influences of high energy arcing fault events on the safety functions of nuclear power plants. The purpose of this paper is to elaborate the characteristics of high energy arcing faults and propose a high energy arcing fault mitigation scheme for medium voltage networks in nuclear power plants.

Clarke 변환을 응용한 3상 유도전동기의 Inter Turn Short Circuit 진단 (Diagnosis of Inter Turn Short Circuit in 3-Phase Induction Motors Using Applied Clarke Transformation)

  • 고영진;김경민
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.518-523
    • /
    • 2023
  • 고정자 권선단락은 미세한 턴이 단락되어 급격히 고장이 심각해짐에 따라 ITSC의 진단이 중요시되고 있다. 그러나, 3상 유도전동기의 노이즈 및 손실등과 유사한 특징을 가짐에 따라 ITSC진단에 많은 어려움이 있다. 이를 효율적으로 진단하기 위해서 인공지능 기법으로 연구되고 있으나, 현장에서는 모델기반 기법이 두루 활용되고 있음에 따라 모델기반 기법에 대한 진단 성능개선 연구가 필요한 실정이다. 이에 본 논문에서는 회전하고 있는 자속에 변화를 무시하며, 전류 성분만을 이용할 수 있도록 Clarke변환 방법을 응용하여 진단방법을 제안하였다. 이에 30분간의 정상 및 ITSC 상태의 측정 결과, 정상상태를 ITSC 상태로 오인식하는 경우 0.2[%], ITSC상태를 정상상태로 오거부하는 경우 0.26[%]로 효율적인 진단 방법임을 실험을 통해 알 수 있었다.

SSA 기법에 기반한 생산조립라인의 디지털 부품 실장 PCB의 검사전략에 대한 연구 (A Study on the Test Strategy Based on SSA Technique for the Digital Circuit Boards in Production Line)

  • 정용채;고윤석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권4호
    • /
    • pp.243-250
    • /
    • 2005
  • Test methodology is diversity by devices and the number of test pattern is tremendous because the digital circuit includes TTL and CMOS family ICs as well as high density devices such as ROM and RAM. Accordingly, the quick and effective test strategy is required to enhance the test productivity. This paper proposes the test strategy which is able to be applied efficiently to the diversity devices on the digital circuit board by analyzing the structure and characteristic of the digital device. Especially, this test strategy detects the faulted digital device or the faulted digital circuit on the digital board using SSA(Serial Signature Analysis) technique based on the polynomial division theory The SSA technique identifies the faults by comparing the reminder from good device with reminder from the tested device. At this time, the reminder is obtained by enforcing the data stream obtained from output pins of the tested device on the LFSR(Linear Feedback Shift Register) representing the characteristic equation. Also, the method to obtain the optimal signature analysis circuit is explained by furnishing the short bit input streams to the long bit input streams to the LFSR having 8, 12, 16, 20bit input/output pins and by analyzing the occurring probability of error which is impossible to detect. Finally, the effectiveness of the proposed test strategy is verified by simulating the stuck at 1 errors or stuck at 0 errors for several devices on typical 8051 digital board.

YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험 (Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films)

  • 심정욱;김혜림;박권배;강종성;이방욱;오일성;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

아크고장 검출기술의 개발 (Development of Arc-Fault Detection Technique)

  • 임용배;전정채;박찬엄;배석명
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1810-1816
    • /
    • 2009
  • 2007년도에 9,128건의 화재가 전기적인 원인에 의해서 발생되었고, 이들 화재에 의해 사망 29명과 부상 262명의 인명피해가 있었다. 아크고장은 전기화재의 주요 원인의 하나로, 일반적으로 높은 열을 발생시키며 쉽게 주변의 인화성물질을 점화시킨다. 그러나 기존의 차단기는 과전류, 단락전류, 누설전류에 대해서만 동작하기 때문에, 이에 대해서는 현재 특별한 보호책이 없는 실정이다. 본 논문은 직렬아크 고장전류에 의한 전선의 발화특성에 대한 실험에서 얻어진 결과를 통해 UL에서 제안하고 있는 기준이 국내의 현실에 적절하지 않음을 제시하였고, 이 결과를 기초로 개발된 기술의 동작특성 실험을 실시하여 아크고장회로를 보호할 수 있는지에 대한 신뢰성을 확인하였다. 모의실험을 통한 동작특성 분석결과, 개발된 아크고장 검출 기술을 적용하면 전기화재의 주요원인인 아크고장에 의한 화재를 현저히 저감시킬 수 있을 것으로 판단된다.

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

전기화재 예측을 위한 마이컴 프로세서 알고리즘 설계에 관한 연구 (A Study on the Design of Microcomputer Processor Algorithm for Electrical Fire Prediction)

  • 곽동걸;최정규;이봉섭;최신형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2015
  • This study has looked into ways to cut the power supply by predicting electrical fire that may occur in low-voltage cable, which is most frequently used in industrial settings and households. In addition, we have designed a system that cuts off electricity to prevent the fire upon occurrence of events that may cause electrical fire, including short circuit, tracking and contact failure. A lot of previous researches have designed arc suppressors built in analog circuit, which left much to be desired such as difficulty in remote control and inability to identify the location of arc suppressor when it is activated. To address these issues, the study seeks to develop an arc suppressor using micom and to verify its performance through simulations designed to detect arc faults.

  • PDF

리플전압을 이용한 병렬아크 사고 감지기 개발 (Development of Parallel Arc Fault Detector Using Ripple Voltage)

  • 최정규;곽동걸
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.