• Title/Summary/Keyword: Short axis

Search Result 343, Processing Time 0.03 seconds

Echocardiograpyhic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog III. Detection of Heartworm (진돗개에서 심장초음파 측정치와 평가와 임상적 응용)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.194-204
    • /
    • 2000
  • Echocardiography was performed to obtain the optimal planes for diagnosis of canine heartworm disease in 11 dogs. Imaging planes were taken the left ventricular outflow tract long-axis view, 4-chamber long-axis view, chordae tendineae level short-axis view and modified pulmonary arteries level short-axis view in the right parasternal window, and aptical 4-chamber long-axis view in hte left parasternal window. After echocaridography, the pulmonary artery valve pat was ligated with double 1-0 silk under the general anesthesia to prevent heartworm moving from pulmonary artery to right ventricle. The dogs were euthanized and examained for heartworms in heart and great vessels. Many adult heartworms were identified ultrasonographically within main pulmonary artery, bifurcation of pulmonary artery and right pulmonary artery, but not identified within right ventricle and atrium. At necropsy, adult heartworms were mainly found in pulmonary artery in 11 days, and also found in right ventricular outflow tract and right ventricle in 2 of 11 dogs. The modified pulmonary arteries level short-axis view was the best imaging plane for identifiying heartworms because the main pulmonary artery, branches of pulmonary artery and right pulmonary artery could be showed. The aortic root internal dimension (AOID) and right pulmonary atery internal dimension (RPAID) were measured from the modified pulmonary ateries level short-axis view and left ventricular outflow tract long-axis view. The RPAID and RPAID/AOID was higher in heartworm infected dogs than normal Korea Jin-do dogs in modified pulmonary arteries level short-axis view, and the AOID, RPAID and RPIAID/AOID was higher than in left ventricular outflow tract long-axis view, respectively. These results indicate that the pulmonary arteries were the major habitat of adult heartworm in canine heartworm disease and the modified pulmonary arteries level short-axis view was the best imaging planes for identifying heartworms because the main pulmonary arteries could be showed. Therefore the modified pulmonary arteries level short-axis view can be used for diagnosing heartworm disease and for monitoring dilation of pulmonary artery.

  • PDF

Boundary extraction about endocardial and epicardial of myocardial SPECT short-axis images using snakes (스네이크를 이용한 심근 SPECT short-axis 영상의 내외벽에 대한 경계선 추출)

  • 김령주;김영철;손병환;이병일;최흥국
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2001.11a
    • /
    • pp.111-114
    • /
    • 2001
  • 게이트 심근 SPECT 영상은 좌심실 구혈률(EF), 확장기말 부피(end-diastolic volume), 수축기말(end-systolic volume)부피 등의 지표로 심근의 기능을 평가하는데 널리 이용된다. 이러한 지표들을 구하기 위해서는 심근 안팎의 경계선을 추출해야 한다. 본 연구는 좌심실의 SPECT short-axis 영상에서 전처리 과정을 거친 영상을 Hough Transform을 이용하여 초기점 설정한 후 심실 내외벽의 경계선을 추출하기 위해 Williams 가 제안한 Active Contour Model(snakes)을 이용하여 심근의 경계선을 자동으로 추출하였다.

  • PDF

Effects of cobble shape on coefficient of drag force (항력계수에 미치는 호박돌 형상의 영향)

  • Park, Sang Deog;Yoon, Min Woo;Yoon, Young Ho
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.419-427
    • /
    • 2017
  • In mountainous rivers, the drag force acting on cobbles abundant in the riverbed surface is important in predicting behavior and response of the river. However there is little research for the drag coefficients of cobbles. This paper is to carry out the experiments for drag force of cobble and analyze the relation between the cobble shape and the drag coefficient. The effects of the shape factor on the drag coefficients $C_D$ when the long axis or the short axis of the cobbles are parallel to the direction of flow velocity were analyzed. The coefficient of drag force increased with the nominal diameter Reynolds number $R_{ep}$. The drag coefficients are greater in short axis than long axis. The coefficient of determination of the relation between $C_D$ and $R_{ep}$ is greater in long axis than short axis. This means that the drag forces acting on the irregularly-shaped cobbles depend on the axis. A change of the drag force distribution has brought about the alternative swing of cobbles. For $R_{ep}$ > 12,000, the amplitude of the swing has been increased sharply and especially was greater in short axis than long axis.

The Echocardiographic Assessment and Clinical Application of Cardiac Disease in Korea Jin-do Dog II. Comparison of Aortic Root Internal Dimension with Right Pulmonary Artery Internal Dimension (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 II. 대동맥기부내경과 우페동맥내경의 비교)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.187-193
    • /
    • 2000
  • Fifteen adult Korea Jin-do dogs were studied by echocardiography to obtain the basic data of the imaging planes and normal references ranges to the aorta and pulmonary artery internal dimension. Measurements of aortic root internal dimension(AOID) and right pulmonary artery internal dimension (RPAID) were made at modified pulmonary arteries level short-axis view and left ventricular outflow tract long-axis view. The aortic root internal dimension and right pulmonary artery internal dimension at modified pulmonary arteries level short-axis view were 18.7$\pm$1.3mm (mean$\pm$SD) and 10.1$\pm$0.8mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. The aortic root internal dimension and right pulmonary artery internal dimension at left ventricular outflow tract long-axis view were 19.3$\pm$1.6 mm and 10.7$\pm$1.3mm, respectively. And RPAID/AOID was 0.5$\pm$0.1mm. These results indicate that modified pulmonary arteries level short-axis view is useful planes to examine the aortic root and pulmonary arteries, and aortic root internal dimension is significantly higher(40~50%)than the right pulmonary artery internal dimension. Therefore measurements of aortic root internal and right pulmonary artery internal dimension can be used for monitoring dilation of pulmonary artery.

  • PDF

Medial and Lateral Crus Elevation to Correct the Secondary Unilateral Cleft Lip-Nasal Deformities (이차성 구순열 비첨부 교정 시 내측 및 외측 하부 비익연골의 동시교정술의 필요성과 효용성)

  • Park, Beyong Yun
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.135-143
    • /
    • 2006
  • The characteristics of the cleft lip nasal deformity is defined in this article in three planes. The alar flaring is explained in X axis, the lower positioning of the alar free margin is imagined in Y axis and the short hemicolumella is in Z axis. Most cleft surgeons have focused on the malposition of the lateral crus of alar cartilage while the author defined it in X and Y axises and tried to correct that deformity of short hemicolumella in Z axis. For the last 13 years the author applied that method in 818 cases of secondary cleft lip nose deformity. Through the columellar splitting incision extended to free margin of the alar not beyond the nasal dorsum, the skin and soft tissue of the webbing deformed the nasal tip was excised in crescent fashion. The dissected short hemicolumella including the medial crus was thus elevated and advanced into the space of the deformed nasal tip after the crescent excision. This procedure should be followed by the correction of the deformities in X and Y axis. The medial crus elevation is more effective and critical way to have the constant and nice outcome than the lateral crus reposition in secondary cleft lip nasal deformity

The Echocardiographic Assessment and clinical Application of Cardiac Disease in Korean Jin-do dog (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 I. 심장초음파 측정치)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.178-186
    • /
    • 2000
  • Echocardiography was performed on 29 normal Korea Jin-do dogs(21 adults and 8 prematures) and the images were taken from chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view, respectively. The following cardiac parameters, in systole and diastole, were measured on the echoocardographic images: aortic dimension(AO), left atrial dimension(LA), left ventricular internal dimention at end-diastole (LVIDd), left ventricular internal dimention at end-systole(LVIDs), interventricular septal wall thickness at end-diastole(IVSd), interventricular septal wall thickness at end-systole(IVSs), left ventricular wall at end-diastole(LVWd), left ventricular wall at end-systole(LVWs). The cardiac parameters were not significantly different between sex and among imaging planes. The size of cardiac parameters increaed as regression lines according to body weights. These results suggest that the chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view can be utilized for the left cardiac examination, and these cardiac parameters can be used to basic dat for diagnosing the cardiac diseases in Korea Jin-do dog.

  • PDF

Study of Fall Detection System According to Number of Nodes of Hidden-Layer in Long Short-Term Memory Using 3-axis Acceleration Data (3축 가속도 데이터를 이용한 장단기 메모리의 노드수에 따른 낙상감지 시스템 연구)

  • Jeong, Seung Su;Kim, Nam Ho;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.516-518
    • /
    • 2022
  • In this paper, we introduce a dependence of number of nodes of hidden-layer in fall detection system using Long Short-Term Memory that can detect falls. Its training is carried out using the parameter theta(θ), which indicates the angle formed by the x, y, and z-axis data for the direction of gravity using a 3-axis acceleration sensor. In its learning, validation is performed and divided into training data and test data in a ratio of 8:2, and training is performed by changing the number of nodes in the hidden layer to increase efficiency. When the number of nodes is 128, the best accuracy is shown with Accuracy = 99.82%, Specificity = 99.58%, and Sensitivity = 100%.

  • PDF

A Study on the Axis Line of Short Span Filled Spandrel Arch Bridge (단경간 폐복식 아치교의 축선에 관한 연구)

  • 구민세;황윤국;조현준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.95-100
    • /
    • 1990
  • The behavior of short span filled spandrel arch bridge of 10 and 21 m span with various axis line, rise and backill height were investigated under the design loads(self weight, earth pressure, temperature load, live load, etc). Even though the behaviors of arch were known as relatively complicated, the followings can be concluded within the limits of this study. The design value of arch bridge increase as the rise decreases, the effects of temperature load become dominant for the design of arch bridge, and governing design factors are occured at springing.

  • PDF

Light Leakage Comparison in a Homogeneously Aligned Nematic Liquid Crystal Display Depending on an Angle between Polarizer Axis and Optic Axis of a Liquid Crystal

  • Song, I.S.;Baik, I.S.;Won, H.K.;Kim, D.S.;Soh, H.S.;Kim, W.Y.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1182-1184
    • /
    • 2004
  • We have studied contrast ratio of a homogeneously aligned nematic liquid crystal (LC) display as a function of the angle between the polarizer axis and LC director. The results show that a cell configuration in which a polarizer axis facing a light source coincides with a short LC axis has a better process margin in terms of high contrast ratio than that of the cell coinciding with a long LC axis.

  • PDF

Comparison of Contrast Ratio in a Homogeneously Aligned Nematic Liquid Crystal Display Depending on an Angle Between Polarizer Axis and Optic Axis of a Liquid Crystal (수평 배향된 네마틱 액정 디스플레이에서 액정의 광축과 편광판축의 편향각에 따른 명암 대비비 값 비교)

  • Song, Il-Sub;Won, Hae-Gyung;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.150-152
    • /
    • 2004
  • We have studied contrast ratio of a homogeneously aligned nematic liquid crystal (LC) display as a function of the angle between the polarizer axis and LC director. The results show that a cell configuration in which a polarizer axis facing a light source coincides with a short LC axis has a better process margin in terms of high contrast ratio than that of the cell coinciding with a long LC axis.

  • PDF