• Title/Summary/Keyword: Short Pulse

Search Result 551, Processing Time 0.031 seconds

A Novel Algorithm for Deinterleaving of D&S PRI and Stagger PRI Signals from the EP Radar (EP 레이더의 D&S PRI와 Stagger PRI 신호식별 알고리즘)

  • Lim, Joong-Soog;Chae, Gyoo-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5372-5378
    • /
    • 2012
  • In this paper, we propose a new method to quickly deinterleave the stagger PRI signals and D&S(Dwell and Switch) PRI signals from the EP radar using the electronic warfare system. While former algorithms were based on stochastic methods only using the first deviation of the TOA of radar signals, this paper uses the first and the second deviation of the TOA of radar signals to deinterleave multiple PRIs of EP radars. When we simulate multiple PRIs of EP radars and test the simulated radar signals using the proposed algorithm, various PRI signals such as fixed, jitter, D&S and stagger PRI are well deinterleaved in a short time. This algorithm is found to be very useful for electronic warfare systems.

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

CNT-PDMS Composite Thin-Film Transmitters for Highly Efficient Photoacoustic Energy Conversion

  • Song, Ju Ho;Heo, Jeongmin;Baac, Hyoung Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.297.2-297.2
    • /
    • 2016
  • Photoacoustic generation of ultrasound is an effective approach for development of high-frequency and high-amplitude ultrasound transmitters. This requires an efficient energy converter from optical input to acoustic output. For such photoacoustic conversion, various light-absorbing materials have been used such as metallic coating, dye-doped polymer composite, and nanostructure composite. These transmitters absorb laser pulses with 5-10 ns widths for generation of tens-of-MHz frequency ultrasound. The short optical pulse leads to rapid heating of the irradiated region and therefore fast thermal expansion before significant heat diffusion occurs to the surrounding. In this purpose, nanocomposite thin films containing gold nanoparticles, carbon nanotubes (CNTs), or carbon nanofibers have been recently proposed for high optical absorption, efficient thermoacosutic transfer, and mechanical robustness. These properties are necessary to produce a high-amplitude ultrasonic output under a low-energy optical input. Here, we investigate carbon nanotube (CNT)-polydimethylsiloxane (PDMS) composite transmitters and their nanostructure-originated characteristics enabling extraordinary energy conversion. We explain a thermoelastic energy conversion mechanism within the nanocomposite and examine nanostructures by using a scanning electron microscopy. Then, we measure laser-induced damage threshold of the transmitters against pulsed laser ablation. Particularly, laser-induced damage threshold has been largely overlooked so far in the development of photoacoustic transmitters. Higher damage threshold means that transmitters can withstand optical irradiation with higher laser energy and produce higher pressure output proportional to such optical input. We discuss an optimal design of CNT-PDMS composite transmitter for high-amplitude pressure generation (e.g. focused ultrasound transmitter) useful for therapeutic applications. It is fabricated using a focal structure (spherically concave substrate) that is coated with a CNT-PDMS composite layer. We also introduce some application examples of the high-amplitude focused transmitter based on the CNT-PDMS composite film.

  • PDF

Active Spinning Training System using Complex Physiological Signals (복합 생체신호를 이용한 능동형 스피닝 트레이닝 시스템)

  • Kim, Cheol-Min;Kang, Gyeong-Heon;Kim, Eun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.591-600
    • /
    • 2015
  • Recently high interest in health and fitness has led to vibrant researches for the active fitness system to learn and enjoy the exercise program for oneself. In this paper, we design and implement the active spinning training system which enables user to have self-learning and experience of customized spinning training program by the biometric and movement information acquired from user's physiological signals. The proposed system provides the appropriate difficulty of spinning program which reflects the concordance rate of spinning dance gestures and the amount of exercising by analyzing the physical status of participant from his brain and pulse waves and recognizing the skeletal movement in real time. For the higher exercise effect, the system offers a virtual personal trainer to show the correct poses and controls the level of difficulty depending on the concordance rate of participant's motions. The experiment with various participants through the proposed system shows that it is able to help users in getting the available exercise effect in comparatively short time.

Core Circuit Technologies for PN-Diode-Cell PRAM

  • Kang, Hee-Bok;Hong, Suk-Kyoung;Hong, Sung-Joo;Sung, Man-Young;Choi, Bok-Gil;Chung, Jin-Yong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.128-133
    • /
    • 2008
  • Phase-change random access memory (PRAM) chip cell phase of amorphous state is rapidly changed to crystal state above 160 Celsius degree within several seconds during Infrared (IR) reflow. Thus, on-board programming method is considered for PRAM chip programming. We demonstrated the functional 512Mb PRAM with 90nm technology using several novel core circuits, such as metal-2 line based global row decoding scheme, PN-diode cells based BL discharge (BLDIS) scheme, and PMOS switch based column decoding scheme. The reverse-state standby current of each PRAM cell is near 10 pA range. The total leak current of 512Mb PRAM chip in standby mode on discharging state can be more than 5 mA. Thus in the proposed BLDIS control, all bitlines (BLs) are in floating state in standby mode, then in active mode, the activated BLs are discharged to low level in the early timing of the active period by the short pulse BLDIS control timing operation. In the conventional sense amplifier, the simultaneous switching activation timing operation invokes the large coupling noise between the VSAREF node and the inner amplification nodes of the sense amplifiers. The coupling noise at VSAREF degrades the sensing voltage margin of the conventional sense amplifier. The merit of the proposed sense amplifier is almost removing the coupling noise at VSAREF from sharing with other sense amplifiers.

Dynamic Respiratory Measurements of Corynebacterium glutamicum using Membrane Mass Spectormetry

  • Wittmann.Christoph;Yang, Tae-Hoon;Irene Kochems;Elmar Heinzle
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.1
    • /
    • pp.40-49
    • /
    • 2001
  • The present work presents a novel approach for the dynamic quantification of respiration rates on a small scale by using lysine-producing Corynebacterium glutamicum ATCC 21253. Cells sampeld from batch cultures at different times were incubated ina 12-ml scale bioreactor equipped with a membrane mass spectrometer. Under dynamic conditions, gas exchange across the gas-liquid phase, specific respiration rates, and RQ values were precisely measured. For this purpose, suitable mass balances were formulated. The transport coefficients for $O_2$ and $CO_2$, crucial for calculating the respiration activity, were determined as $k_La_{O2}=9.18h^{-1}$ and $k_La_{CO2}=5.10h^{-1}$ at 400 rpm. The application of the proposed method to batch cultures of C. glutamicum ATCC 21253 revealed the maximum specific respiration rates of $q_{O2}=8.4\;mmol\;g^{-1}h^{-1}\;and\;q_{CO2}=8.7\;mmol\;g^{-1}h^{-1}$ in the middle of the exponential growth phase after 5 h of cultivation. When the cells changed from growth to lysine production due to the depletion of the essential amino acids theonine, methionine, and leucine, $q_{O2}\;and\;q_{CO2}$ decreased significantly and RQ increased. The respiration data exhibited an excellent agreement with previous cultivations of the strain [13]. This confirms the potential of the developed approach to realistically reflect the metabolic activities of cells at their point of sampling. The short-term influence of added threonine, methionine, and leucine was highest during the shift from growth to lysine production, where $q_{O2}\;and\;q_{CO2}$ increased 50% within one minute after the pulse addition of these compounds. Non-growing, yet lysine-producing cells taken from the end of the batch cultivation revealed no metabolic stimulation with the addition of threonine, methionine, and leucine.

  • PDF

Surface Modification and Heat Treatment of Ti Rod by Electro Discharge (전기방전에 의한 Ti rod의 열처리 및 표면개질 특성에 관한 연구)

  • Byun, C.S.;Oh, N.H.;An, Y.B.;Cheon, Y.W.;Kim, Y.H.;Cho, Y.J.;Lee, C.M.;Lee, W.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.168-172
    • /
    • 2006
  • Single pulse of 2.0 to 3.5 kJ from $150{\mu}F$ capacitor was applied to the cp Ti rod for its surface modification and heat treatment. Under the conditions of using 2.0 and 2.5 kJ of input energy, no phase transformation has been occurred. However, the hardness and tensile strength decreased and the elongation increased after a discharge due to a slight grain growth. By using more than 3.0 kJ of input energy, the electro discharge made a phase transformation and the hardness at the edge of the cross section increased significantly. The Ti rod before a discharge was lightly oxidized and was primarily in the form of $TiO_2$. However, the surface of the Ti rod has been instantaneously modified by a discharge into the main form of TiN from $TiO_2$. Therefore, the electro discharge can modify its surface chemistry in times as short as $200{\mu}sec$ by manipulating the input energy, capacitance, and discharging environment.

Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

  • Menacer, Arezki;Champenois, Gerard;Nait Said, Mohamed Said;Benakcha, Abdelhamid;Moreau, Sandrine;Hassaine, Said
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.219-228
    • /
    • 2009
  • The growing application and the numerous qualities of induction motors (1M) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ${\odot}$ the IM is directly by the balanced three-phase network voltage source, ${\odot}$ the IM is fed by a sinusoidal current source given the controlled by hysteresis, ${\odot}$ the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ${\odot}$ the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

Fabrication of Glass Microstructure Using Laser-Induced Backside Wet Etching (레이저 습식 후면 식각공정을 이용한 미세 유리 구조물 제작)

  • Kim, Bo Sung;Park, Min Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.967-972
    • /
    • 2014
  • The good light permeability and hardness of glass allow it to be used in various fields. Non-conventional machining methods have been used for glass machining because of its brittle properties. As one non-contact machining method, a laser has advantages that include a high machining speed and the fact that no tool making is required. However, glass has light permeability. Thus, the use of a laser to machine glass has limitations. A nanosecond pulse laser can be used at low power for laser-induced backside wet etching, which is an indirect method. In previous studies, a short-wave laser that had good light absorption but a high price was used. In this study, a near-infrared laser was used to test the possibility of glass micro-machining. In particular, when deeper machining was conducted on a glass structure, more problems could result. To solve these problems, microstructure manufacturing was conducted using ultrasonic vibration.

Spectroscopic Study of the X-ray Dip at Pre-eclipse Phase of Hercules X-1

  • Choi, C.S.;Nagase, F.;Makino, F.;Dotani, T.;Min, K.W.
    • Bulletin of the Korean Space Science Society
    • /
    • 1992.10a
    • /
    • pp.21-21
    • /
    • 1992
  • The X-ray binary pulsar Her X-1 was observed with Ginga on 1988 August 28 during the orbital phase of 0.76 to 0.85 at the main-on phase of the 35 day cycle. During the observations the X-ray intensity varied by a factor of five or more on a time scale as short as 30 sec, due mostly to the soft X-ray absorption in the pre-eclipse phase. From the studies of pulse profiles and energy spectra, we revealed that there exists in the dipphase an unpulsed component which is "3% of the intensity at the non-absorbed high-level. We suggest that scattering of the source continuum by the optically thin hot corona is responsible for the unpoised component. In the spectral analysis, we find that the high-state non-absorbed spectra can be fitted by a power-law without absorption, and the spectra observed in the different abgorption states by two components of a power-law with the same photon index. An iron-K emission line is required in to the cases of fitting. The estimated equivalent width of the iron line varies from 0.18 to 0.51 key according to the change in the absorption column density along the line of sight. We suggest that the fluorescent iron line arises in a cool and relatively small region, like the Alfvensur face, and may be partially intercepted by the optically thick gas cloud passing across the line of sight.1 Korea Astronomy Observatorya The Institute of Space and Astronautical Science in Japan3 Korea Advanced Institute of Science and Technology

  • PDF