• Title/Summary/Keyword: Short Pulse

Search Result 551, Processing Time 0.03 seconds

Anti-Jamming and Time Delay Performance Analysis of Future SATURN Upgraded Military Aerial Communication Tactical Systems

  • Yang, Taeho;Lee, Kwangyull;Han, Chulhee;An, Kyeongsoo;Jang, Indong;Ahn, Seungbeom
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.9
    • /
    • pp.3029-3042
    • /
    • 2022
  • For over half a century, the United States (US) and its coalition military aircrafts have been using Ultra High Frequency (UHF) band analog modulation (AM) radios in ground-to-air communication and short-range air-to-air communications. Evolving from this, since 2007, the US military and the North Atlantic Treaty Organization (NATO) adopted HAVE QUICK to be used by almost all aircrafts, because it had been revealed that intercepting and jamming of former aircraft communication signals was possible, which placed a serious threat to defense systems. The second-generation Anti-jam Tactical UHF Radio for NATO (SATURN) was developed to replace HAVE QUICK systems by 2023. The NATO Standardization Agreement (STANAG) 4372 is a classified document that defines the SATURN technical and operational specifications. In preparation of this future upgrade to SATURN systems, in this paper, the SATURN technical and operational specifications are reviewed, and the network synchronization, frequency hopping, and communication setup parameters that are controlled by the Network (NET) Time, Time Of Day (TOD), Word Of Day (WOD), and Multiple Word of Day (MWOD) are described in addition to SATURN Edition 3 (ED3) and future Edition 4 (ED4) basic features. In addition, an anti-jamming performance analysis (in reference to partial band jamming and pulse jamming) and the time delay queueing model analysis are conducted based on a SATURN transmitter and receiver assumed model.

Design of Pixel Circuit of Micro LED Display with Double Gate Thin Film Transistors (더블 게이트 박막 트랜지스터를 활용한 Micro LED 디스플레이 화소 회로 설계)

  • Kim, Taesoo;Jeon, Jaehong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.50-55
    • /
    • 2022
  • Due to the wavelength shift problem of micro LED caused by the change of current density, the active matrix driving pixel circuit that is used in OLED cannot be applied to micro LED displays. Therefore, we need a gray scale method based on modulation of duration time of light emission. In this study, we propose the PWM-controlled micro LED pixel circuit based on CMOS thin film transistors (TFTs). By adopting CMOS inverter structure, we can reduce the number of storage capacitors from the circuit and make the operating speed of the circuit faster. Most of all, our circuit is designed to make operating speed of PWM circuit faster by adopting feedback effect through double gate TFT structure. As a result, it takes about 4.7ns to turn on the LED and about 5.6ns to turn it off. This operating time is short enough to avoid the color distortion and help the precise control of the gray scale.

Projection of future short duration rainfall quantile using rainfall disaggregation technique (강우분해기법을 이용한 미래 단기 확률 강우량 전망)

  • Lee, Jeonghoon;Seo, Jiyu;Kim, Sangdan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.428-428
    • /
    • 2022
  • 본 연구에서는 최근 RCM을 이용하여 생산된 미래 강우자료를 1시간강우량으로 변환하기 위한 Neyman-Scott Rectangular Pulse(NSRP) 모델 기반의 강우분해기법을 개발하고 이를 기반으로 짧은 지속시간에 대한 확률강우량이 어떻게 변화하는지 전망해보고자 하였다. 강우분해기법의 성능평가는 관측자료를 이용하여 수행되었으며, 관측 시계열을 우수하게 모의했으나 일최대 시간 강수량이 20mm를 초과하는 경우 불확실성이 증가함에 따라 사용에 주의가 필요할 것으로 판단된다. 미래 확률강우량 전망결과는 모든 지점(울산, 부산, 창원, 밀양)에서 향후 재현기간별 1시간 확률강우량이 증가될 것으로 전망되었다. 울산과 밀양 지점의 경우, 재현기간에 클수록 증가율 또한 증가하는 경향이 뚜렷하게 나타났는데 이는 상대적으로 복잡한 산악지역 내 위치하고 있고, 다른 지점보다 산지효과 영향이 크기 때문으로 판단된다. 부산과 창원지점은 다른 두 지점에 비해 재현 기간별 확률강우량의 변동성이 크게 나타났는데, 이는 해안에 가깝에 위치해 있어 RCM별 불확실성이 다소 크게 작용한 것으로 판단된다. 특히 과거 200년 빈도 확률강우량 보다 미래 50년미만 빈도 확률 강우량이 더 커질 수 있는 가능성을 확인하였다. 다양한 불확실성이 포함되어 있는 결과이긴 하나 이러한 결과를 기반으로 곧 도래할 미래의 도시유역 방재성능 재정비가 필요할 것으로 사료된다. 아울러, 극한 강우발생 가능성이 높아질 수 있음을 의미하기 때문에 이에 대한 새로운 수자원의 이수와 치수 대비를 위한 구조적/비구조적 대책이 시급할 것으로 판단된다.

  • PDF

Simulations for the cesium dynamics of the RF-driven prototype ion source for CRAFT N-NBI

  • Yalong Yang;Yong Wu;Lizhen Liang;Jianglong Wei;Rui Zhang;Yahong Xie;Wei Liu;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1145-1152
    • /
    • 2024
  • To realize an initial objective of the negative ion-based neutral beam injection (N-NBI) at the Comprehensive Research Facility for Fusion Technology (CRAFT) test facility, which targets an H0 beam power of 2 MW at an energy of 200-400 keV and a pulse duration of 100 s, it is crucial to study the cesium dynamics of the negative ion source. Here a numerical simulation program CSFC3D is developed and applied to simulate the distribution and time dynamics of cesium during short pulses. The calculations show that most of the cesium on the plasma grid (PG) area originates from the release of cesium that is accumulated within the ion source in the plasma phase. Increasing the wall temperature reduces the loss of cesium on the wall of the ion source. Furthermore, the thickness of the cesium monolayer is directly influenced by the PG temperature. Both simulated and experimental results demonstrate that maintaining the PG temperature between 180 ℃ and 200 ℃ is essential for enhancing the performance of the ion source and optimizing the cesium behavior.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Flowering Control by Using Red Light of Chrysanthemum (적색광을 이용한 국화의 개화조절)

  • Hong, Seung-Chang;Kwon, Soon-Ik;Kim, Min-Kyeong;Chae, Mi-Jin;Jung, Goo-Bok;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.2
    • /
    • pp.123-127
    • /
    • 2013
  • BACKGROUND: The incandescent bulb and compact fluorescent lamp are widely using as a light sources for daylength extension of chrysanthemum. But, these light sources consume a lot of electricity and have short longevity. A light-emitting diode (LED) is a semi conductor light source. LEDs have many advantages over incandescent light sources including lower energy consumption, longer lifetime. In this study, we investigated the intensity of red light to control flowering of chrysanthemum (Dendranthema grandiflorum cv. "Shinma") by using LEDs. METHODS AND RESULTS: The red (660 nm) and far-red (730 nm) light were irradiated subsequently to investigate photo-reversible flowering responses of chrysanthemum. The flowering of chrysanthemum was inhibited by night interruption with red light but subsequently irradiated far-red light induced the flowering of chrysanthemum. This photoreversibility, reversion of the inductive effect of a brief red light pulse by a subsequent far-red light pulse, is a property of photo responses regulated by the plant photoreceptor phytochrome B. Four different intensity of red light of 0.7, 1.4, 2.1, and $2.8{\mu}mol/m^2/s$ (PAR) were irradiated at growth room in order to determine the threshold for floral inhibition of chrysanthemum. Over $1.4{\mu}mol/m^2/s$ of the red lights irradiated chrysanthemums were not flowered. The plant length, fresh weight, number of leaves, and leaf area of chrysanthemum irradiated with red light were increased by 17%, 36%, 11%, and 48%, respectively, compared to those of compact fluorescent lamp. CONCLUSION(S): The red light and subsequential far-red light showed that the photoreversibility on flowering of chrysanthemum. The red light ($1.4{\mu}mol/m^2/s$ of red LEDs) and white light (50 Lux of compact fluorescent lamp) have the same effect on inhibition of flowering in chrysanthemum. Additionally, the red light increased the plant height and dry weight of chrysanthemum.

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

Development of MRI Simulator Early Diagnosis Program for Self Learning (자가 학습을 위한 MRI Simulator 초기 검사 프로그램 개발)

  • Jeong, Cheon-Soo;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.403-410
    • /
    • 2015
  • Since 1970, MRI has greatly been developing in terms of strength of magnetic field, the number of receipt channels, and short time of examination. With the development of digital systems and wireless network, hospitals have also acquired, saved, and managed digital images taken by various kinds of medical imaging equipment. However, domestic universities fail to provide practice training course independently thanks to expensive practice equipment and high maintenance cost, and rely on clinical training. Therefore, this study developed a MR patient diagnosis program based on Windows PC to help out students before their working in clinical filed. The designed Relational Database of MRI Simulator is made up of seven tables according to functions and data characteristics. Regarding the designed patient information, each stepwise function was classified by the patient registration method in clinical field. In addition, on the assumption of the basic information for diagnosis, each setting and content were classified. The menu by execution step was arrayed on the left side for easy view. For patient registration, a patient's name, gender, unique ID, birth date, weight, and other types of basic information were entered, and the patient's posture and diagnosis direction were set up. In addition, the body regions for diagnosis and Pulse Sequence were listed for selection. Also, Protocol name and other additional factors were allowed to be entered. The final window was designed to check diagnosis images, patient information, and diagnosis conditions. By learning how to enter patient information and change diagnosis conditions in this program, users will be able to understand more theories and terms learned in practice and thereby to shorten their learning time in actual clinical work.

Design and Implementation of FMCW Radar Signal Processor for Drone Altitude Measurement (드론 고도 측정용 FMCW 레이다 신호처리 프로세서 설계 및 구현)

  • Lim, Euibeen;Jin, Sora;Jung, Yongchul;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.554-560
    • /
    • 2017
  • Accurate altimetry is required for the reliable flight control of drones or unmanned air vehicles (UAVs), and the radar altimeter is commonly used owing to its accuracy for the ground level. Due to the limitation for size, weight and power consumption, the frequency modulated continuous wave (FMCW) radar is appropriate for drone because it has lower complexity than that of pulse Doppler (PD) radar. Especially, fast-ramp FMCW radar, which transmits linear FM signal during very short period, is generally utilized, because it is robust for the ego-motion of drone. Therefore, we present the design and implementation results of the radar signal processor (RSP) for fast-ramp FMCW radar system. The proposed RSP was designed with Verilog-HDL and implemented with Altera Cyclone-IV FPGA device. Implementation results show that the proposed RSP includes 27,523 logic elements, 15,798 registers and memory of 138Kbits and can measure the altimeter at the rate of 100Hz with the operating frequency of 50MHz.

Sterilization of Yakju(Rice Wine) Using a Batch-type High Voltage Pulsed Electric Field System (고전장펄스를 이용한 약주의 회분식 살균)

  • Kim, Su-Yeon;Park, Young-Seo;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1247-1253
    • /
    • 1999
  • Yakju(rice wine) was sterilized with high-voltage pulses of short time on a batch pulsed electric field(PEF) system. The initial microbial counts of Yakju were 7.52 X $10^4\;CFU/mL$ for total aerobes, 2.20 X $10^4\;CFU/mL$ for lactic acid bacteria and 7.08 X $10^4\;CFU/mL$ for yeasts. The pH, acidity and electric conductivity of Yakju were 3.36, 0.462% and 1.24 mS/cm, respectively. Yakju was treated with 2-250 of pulses exponential-wave formed electric pulses under the field strength of 12.5-25 kV/cm. The critical strengths of the electrical field for the sterilization of Yakju were 7.5 kV/cm for total aerobes, 8.5 kV/cm for lactic acid bacteria and 6.5 kV/cm for yeasts. Logarithmic survival rates decreased linearly at low pulse number, but curvilinearly at high pulse number. The PEF sterilization kinetics of Yakju could be analysed by In s = In A-k In (n) and the sterilization rate constant increased with electric field strength and the size of target microorganisms. No changed in pH, acidity, and the growth of microorganisms were found in the PEF treated Yakju during the storage for 6 weeks at both $4^{\circ}C$ And $30^{\circ}C$.

  • PDF