• Title/Summary/Keyword: Short Pulse

Search Result 551, Processing Time 0.036 seconds

Pulse Stretching Effect in XeCl Excimer Laser (XeCl 엑시머 레이저에서의 Pulse Stretching 효과)

  • Chu, Hong;Kim, Dong-Hwan;Lee, Soo-Man;John, Young-Min;Choi, Sang-Sam;Park, Dae-Yoon
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.447-451
    • /
    • 1993
  • Long pulse XeCl excimer laser with 150 ns (FWHM) pulse duration is developed using a simple capacitor-charge transfer circuit. We measured the laser pulse width varying the gas mixture ratio and capacitance ratio, which dominantly affect the pulse width. In this way we can easily stretch the pulse width from short pulse to long pulse. The pulse width was stretched by 120 ns as the partial pressure of HC1 and Xe gas was reduced under constant gas mixture ratio ([Xe]/[HCl]= 15), and by varying the capacitance ratio (Cm/Cp) under fixed pressure, the pulse width was stretched by 60 ns.

  • PDF

Dependence of pulse width on the operating parameters in a gain-switched semiconductor laser (이득 스위칭 반도체 레이저에서 동작 파라메터에 대한 출력 펄스 폭의 의존성)

  • 이상훈;명승일;이명우;서동선
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.101-108
    • /
    • 1998
  • We examine experimentally the dependence of output width on DC bias, RF power, and RF frequency in a gain-switched semiconductor laser. The optimum short pulses are obtained around threshold DC bias. The DC bias to generatoe shorter pulses decreases the RF power increases, whereas it increases to above threshold as the RF freqnecy increases. The pulse width becomes less sensitive to the variations of the DC bias, as the RF bias, or frquency increases.

  • PDF

Study about the Application of Rogowski Coil for measuring Partial Discharge Current (부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구)

  • Lee, Kang-Won;Yoon, Sung-Cheol;Kim, Myung-Yong;Baik, Kwang-Sun;Na, Dong-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF

Design of Mutually Orthogonal Polyphase Complementary Sequences for Ultrasound Imaging (초음파 영상을 위한 직교 상보수열의 설계)

  • 김배형;김태호;송태경
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.393-396
    • /
    • 2002
  • In this paper, we present a new method for generating a set of complementary sequences that can be simultaneously transmitted and yet compressed into a short pulse on reveive, and its application to ultrasound imaging. This new complementary sequences can be designed based on a filter bank theory. The new complementary sequences can be used to improve the SNR of ultrasound imaging without sacrificing the spatial resolution and frame rate, compared to conventional pulse-echo imaging. Computer simulations are performed to verify the proposed method.

  • PDF

Novel Design of Ultrashort Pulse Excimer Laser Amplifier System I (Energy Characteristics)

  • Lee, Young-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.1
    • /
    • pp.39-43
    • /
    • 2003
  • The technology required to advance the state of the art of ultra-high-intensity excimer amplifier construction to the 100 J/100fs output pulse level is identified. The preliminary design work for very large final amplifier pumped by electron beam module is described, and key design problems and approaches are presented and discussed in detail based on the recent experimental and theoretical results.

Fabrication of Balanced CPM(Colliding Pulse Mode-locked) Ring Dye Laser (Balanced CPM(Colliding Pulse Mode-locked) 링 색소 레이저 제작)

  • 정영붕;김동호;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.185-190
    • /
    • 1990
  • Balanced CPM ring dye laser was fabricated. Pulses as short as 62 fs were measured using noncollinear second harmonic generation autocorrelator. The optimum conditions were studied by changing the concentration of staturable absorber, pumping power of Ar+ laser and alignments of the intracavity four-prism sequence.

  • PDF