• 제목/요약/키워드: Short Pin

검색결과 93건 처리시간 0.025초

중족골두 무혈성 괴사에서 생체흡수성 핀으로 고정한 배측 쐐기 절골술 (Dorsal Wedge Osteotomy Using Bioabsorbable Pins for the Treatment of Freiberg's Disease)

  • 공현식;백구현;김지형;정문상
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.59-63
    • /
    • 2005
  • Purpose: To present the procedure and results of dorsal wedge osteotomy fixated by bioabsorbable polyglycolide pins for the treatment of symptomatic Freiberg's disease. Materials and Methods: From January 1997 to December 2002, six patients with Freiberg's disease underwent dorsal wedge osteotomy of the metatarsal neck to bring the healthy plantar part of the metatarsal head into articulation. Bioabsorbable polyglycolide pins were used for the fixation and short-leg walking cast was applied for 4 weeks. Results: All patients returned to full daily activities without pain in three months after the operation. Radiographically, solid healing of the osteotomy was observed at average ten weeks. The active range of motion of the metatarsophalangeal joint increased by a mean gain of 30 degrees, and no complication such as displacement, osteolysis or sinus formation was observed. Conclusion: Dorsal wedge osteotomy fixated by bioabsorbable pins for patients with symptomatic Freiberg's disease is effective procedure that provides relatively early range of motion exercise and avoids second procedure for implant removal.

  • PDF

Development of Defect Inspection System for PDP ITO Patterned Glass

  • Song Jun-Yeob;Park Hwa-Young;Kim Hyun-Jong;Jung Yeon-Wook
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권3호
    • /
    • pp.18-23
    • /
    • 2006
  • The formation degree of sustain (ITO pattern) determines the quality of a PDP (Plasma Display Panel). Thus, in the present study, we attempt to detect 100% of the defects that are larger than $30{\mu}m$. Currently, the inspection method in the PDP manufacturing process is dependent upon the naked eye or a microscope in off-line mode. In this study, a prototype inspection system for PDP ITO patterned glass is developed. The developed system, which is based on a line-scan mechanism, obtains information on the defects and sorts the defects by type automatically. The developed inspection system adopts a multi-vision method using slit-beam formation for minimum inspection time and the detection algorithm is embodied in the detection ability. Characteristic defects such as pin holes, substances, and protrusions are extracted using the blob analysis method. Defects such as open, short, spots and others are distinguished by the line type inspection algorithm. It was experimentally verified that the developed inspection system can detect defects with reliability of up to 95% in about 60 seconds for the 42-inch PDP panel.

PDP ITO 결함 검출기술에 관한 연구 (A Study on Inspection Technology of PDP ITO Defect)

  • 송준엽;박화영;정연욱;김현종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.191-195
    • /
    • 2003
  • The formation degree of sustain (ITO pattern) decides quality of PDP (plasma display panel). For this reason. it makes efforts in search defects more than 30 ${\mu}{\textrm}{m}$. Now, the existing inspection process is dependent upon naked eye or SEM equipment in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP ITO glass. This system creates information that detects and sorts kind of defect automatically. Design ed inspection technology adopts line-scan method by slip-beam formation for the minimum of inspection time and image processing algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix which draws up an approach to geometry. A characteristic of area-shaped defects, as pin hole, substance, protrusion et al, are extracted from blob analysis method. Defects, as open, short, spots, et al, are distinguished by line type inspection algorithm. In experiment results, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds

  • PDF

ZnO:Al 투명전도막을 이용한 높은 개방전압을 갖는 비정질 실리콘 박막 태양전지 제조 (Amorphous silicon thin-film solar cells with high open circuit voltage by using textured ZnO:Al front TCO)

  • 이정철;안세진;윤재호;송진수;윤경훈
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.31-36
    • /
    • 2006
  • Superstrate pin amorphous silicon thin-film(a-Si:H) solar cells are prepared on $SnO_2:F$ and ZnO:Al transparent conducting oxides(TCO) in order to see the effect of TCO/p-layers on a-Si:H solar cell operation. The solar cells prepared on textured ZnO:Al have higher open circuit voltage VOC than cells prepared on $SnO_2:F$. Presence of thin microcrystalline p-type silicon layer(${\mu}c-Si:H$) between ZnO:Al and p a-SiC:H plays a major role by causing improvement in fill factor as well as $V_{OC}$ of a-Si:H solar cells prepared on ZnO:Al TCO. Without any treatment of pi interface, we could obtain high $V_{OC}$ of 994mV while keeping fill factor(72.7%) and short circuit current density $J_{SC}$ at the same level as for the cells on $SnO_2:F$ TCO. This high $V_{OC}$ value can be attributed to modification in the current transport in this region due to creation of a potential barrier.

  • PDF

피라미드 트러스 코어 단위셀의 기계적 특성에 관한 해석적 및 수치적 연구 (Analytical and Numerical Study on Mechanical Behavior of Unit Cell of Pyramidal Truss Core Structures)

  • 김상우;이영선;강범수
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.623-631
    • /
    • 2011
  • Metallic sandwich panels based on a truss core structure have been developed for a wide range of potential applications with their lightweight and multi-functionality. Structural performance of sandwich panels can be predicted from the studies on mechanical behavior of a unit cell of truss core structures. Analytical investigations on the unit cell provide approximated guidelines for the design of overall core structures for a specific application in short time. In this study, the effects of geometrical parameters on mechanical behavior of a pyramidal shape of unit cell were investigated with analytical models. The unit cell with truss member angle of 45 degree was considered as reference model and other models were designed to have the same weight and projected area but different truss member angle. All truss members were assumed to be connected with pin joint in analytical models. Under the assumptions, the equivalent strength and stiffness of the unit cell under compressive and shear loads were predicted and compared. And finally, the optimum core member angle to have maximum mechanical property could be calculated and verified with FE analysis results.

엔진 연결봉 베어링의 최소 유막 두께에 관한 연구 (A Study, on the Minimum Oil Film Thickness of Connecting-rod Bearing in Engine)

  • 최재권;허곤;한동철
    • Tribology and Lubricants
    • /
    • 제10권1호
    • /
    • pp.14-26
    • /
    • 1994
  • The minimum oil film thickness(MOFT) in the connecting-rod bearing of a 1.5 liter, L-4, gasoline engine is measured up to 5500 rpm and calculated to study the dynamically loaded engine bearing. Short bearing approximation and Mobility method are used for theoretical analysis of oil film characteristics. And cylinder pressure, crank-pin surface temperature and bearing temperature are measured as the input data of theoretical analysis. The MOFT are measured by the total capacitance method(TCM). To improve the reliability of the test results, a reasonable determination method of bearing clearance is introduced and used, and the effects of cavitation and aeration on the test results are neglected. The crankshaft is grounded by means of a slip ring. A scissor type linkage system was developed to measure the MOFT and bearing temperature. The effects of engine speed, load and oil viscosity on the measured and calculated minimum oil film thicknesses are investigated at 1500 to 5500 rpm. From the comparison between the measured and calculated MOFT, it is found that a qualitative similarity exists between them, but in all cases, the measured MOFT are smaller than those calculated.

Hydrophobicity of Amino Acids in Protein Context

  • Cho, Hanul;Chong, Song-Ho;Ham, Sihyun
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제3회(2014년)
    • /
    • pp.103-113
    • /
    • 2014
  • Hydrophobicity is the key concept to understand the role of water in protein folding, protein self-assembly, and protein-ligand interaction. Conventionally, hydrophobicity of amino acids in a protein has been argued based on hydrophobicity scales determined for individual free amino acids, assuming that those scales are unaltered when amino acids are embedded in a protein. Here, we investigate how the hydrophobicity of constituent amino acids depends on the protein context, in particular, on the total charge and secondary structures of a protein. To this end, we compute and analyze the hydration free energy - free energy change upon hydration quantifying the hydrophobicity - of three short proteins based on the integral-equation theory of liquids. We find that the hydration free energy of charged amino acids is significantly affected by the protein total charge and exhibits contrasting behavior depending on the protein net charge being positive or negative. We also observe that amino acids in the central ${\beta}$-strand sandwiched by ${\beta}$-sheets display more enhanced hydrophobicity than free amino acids, whereas those in the ${\alpha}$-helix do not clearly show such a tendency. Our results provide novel insights into the hydrophobicity of amino acids, and will be valuable for rationalizing and predicting the strength of water-mediated interaction involved in the biological activity of proteins.

  • PDF

폴리실라잔계 실란트를 이용한 정전척 실링특성 향상 연구 (Improvement of Sealing Property of Electrostatic Chuck by Applying Polysilazane Sealant)

  • 최재영;박현수;손민규;정창오;김우병
    • 한국표면공학회지
    • /
    • 제49권6호
    • /
    • pp.567-574
    • /
    • 2016
  • We have analyzed chemical properties of polysiloxane and polysilazane films, respectively, as sealing materials for electrostatic chuck (ESC) and have investigated the possibility of polysilazane as an alternative sealant to polysiloxane. It has been revealed that Si-O with organic bonding ($Si-CH_3$) existed in polysiloxane films compared to only pure Si-O bonding in polysilazane films. The sealing property of polysilazane has been found outstanding even in a short time of application. In the polysiloxane films containing $H_2O$, pin holes have been found possibly due to $CO_2$ gas evolution, and low adhesion with Si substrate has been observed after heat stress test in connection with the existence of organic bonding. After acid resistance test in 0.5 vol.% HF, 68 wt.% $HNO_3$, and 37 wt.% HCl solution, polyilazane films have shown a longer survival times. Compared to the conventional polysiloxane sealant, polysilazane is expected as a new sealing material because of good thermal and chemical stability.

Cross Decoupler를 이용한 LTE 펨토셀용 4-port MIMO 안테나 (A 4-port MIMO Antenna for LTE Femtocell using Cross Decoupler)

  • 안상권;정계택;이화춘;곽경섭
    • 한국ITS학회 논문지
    • /
    • 제13권2호
    • /
    • pp.50-56
    • /
    • 2014
  • 본 논문에서는 LTE 700MHz(Band12, 13, 14, 17, 28, 44) 대역에서 동작 가능한 4개의 포트를 가진 펨토셀(Femtocell) MIMO 안테나를 설계 제작하였다. 마이크로스트립 패치 안테나를 기반으로 임피던스 매칭을 위하여 쇼트핀을 이용하였고, 한정된 크기에서 충분한 안테나 격리도를 얻기 위해 십자형 디커플러를 이용하였다. 시뮬레이션에 의한 최적화된 파라미터를 가지고 제작하였으며, 제작된 안테나는 VSWR${\leq}2$에서 105MHz(0.698~0.803) 대역폭을 만족하고 1.97dBi의 이득과 격리도는 13dB이상의 값을 얻었다. MIMO 안테나의 성능을 판단하는 주요 파라미터인 안테나간 상관계수는 0.2 이하의 결과를 얻었다.

Protein Context-Dependent Hydrophobicity of Amino Acids in Protein

  • Cho, Hanul;Ham, Sihyun
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.163-166
    • /
    • 2016
  • Hydrophobicity is the key concept to understand the water plays in protein folding, protein aggregation, and protein-protein interaction. Traditionally, the hydrophobicity of protein is defined based on the scales of the hydrophobicity of residue, assuming that the hydrophobicity of free amino acids is maintained. Here, we explore how the hydrophobicity of constituting amino acids in protein rely on the protein context, in particular, on the total charge and secondary structures of a protein. To this end, we calculate and investigate the hydration free energy of three short proteins based on the integral-equation theory of liquids. We find that the hydration free energy of charged amino acids is significantly affected by the protein total charge and exhibits contrasting behavior depending on the protein total charge being positive or negative. We also observe that amino acids in the ${\beta}-sheets$ display more enhanced the hydrophobicity than amino acids in the loop, whereas those in the ${\alpha}-helix$ do not clearly show such a tendency. And the salt-bridge forming amino acids also exhibit increase of the hydrophobicity than that with no salt bridge. Our results provide novel insights into the hydrophobicity of amino acids, and will be valuable for rationalizing and predicting the strength of water-mediated interaction involved in the biological activity of proteins.

  • PDF