• 제목/요약/키워드: Short Circuit Test

검색결과 259건 처리시간 0.023초

디지털 측정 및 분석장치의 적용에 관한 연구 (Consideration on data acquisition and analysis system for using short-circuit tests)

  • 김맹현;서윤택;김대원;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.38-40
    • /
    • 2001
  • Measuring technology based on the computer and software is used worldwideiy by the aids of remarkably improved digital technology and measuring devices, and the electro- magnetic interference due to high currents and high voltages is being solved by the helps of applied optic instrumentation technology. The automatic acquisition, analysis and storage system of test data is available for utilizing the numerical computation technology. The measuring accuracy and testing efficiency are thus much higher because of the developed technologies. In this paper, the construction of data acquisition system in KERI including measuring devices and its application to the short circuit test are described, and additionally the algorithm of the analyzing program for the automatic process of test data and the results of analyses are described.

  • PDF

간이 합성시험설비의 구성 및 회로특성 (Construction and Circuital Characteristics of Simple Synthetic Test Facility)

  • 이정희;박경엽;장기찬;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.168-170
    • /
    • 1995
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. The analyzed results of the circuit which can be useful for the design stage of the testing facility are also shown. EMTP has been used to analyze the circuit. Two cases of short-circuit test results obtained from the simple synthetic testing facility in KERI are shown with the waveforms of current and voltage. The results also indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

25.8kV 25kA 열팽창분사식 가스차단기 개발에 관한 연구(II) - 팽창실 용적이 차단성능에 미치는 영향 - (A Study on the Development of 25.8kV 25kA Gas Circuit Breaker Using Thermal-Expansion Principle(II))

  • 송기동;박경엽;신영준;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.80-82
    • /
    • 1996
  • This paper deals with the effects of the volume of thermal expansion chamber on the interrupting performance in thermal expansion type 25.8kV 25kA gas circuit breaker. Model interrupters with 5 type thermal expansion chamber were designed and manufactured. Short-circuit tests were carried out for those model interrupters with 25kA breaking current. Pressure rise in the expansion chamber were measured and compared with the calculated one which was obtained from a self-developed program in our team. The analysis on the interrupting performance of each model interrupter has been done on the base of the short-circuit test results.

  • PDF

단락시험 전.후의 변압기 진동신호 특성 (Characteristics of Vibration Signal in the Transformer before & after Short Circuit Test)

  • 강창구;김현식;김영식;김재철;정찬수;곽희로;주병수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1359-1361
    • /
    • 1995
  • This paper describes the method of diagnosis for power transformer, using vibration signal analysis. Vibration signal to be made from transformer is the liner combination of load current, applied voltage and internal temperature. This study measured the vibration signal by before and after short circuit test of the transformer. And the signal analysis and comparison was carried out for AR modeling and frequency analysis.

  • PDF

삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션 (Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test)

  • 이응로;이승제;이찬주;고태국;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구 (Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current)

  • 심상보;이춘하;김시국
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.114-122
    • /
    • 2016
  • 본 논문은 리튬배터리의 고온 및 단락전류에 따른 폭발 및 화재 위험성을 분석하기 위한 연구이다. 이에 대표적인 리튬배터리 종류인 리튬폴리머배터리 및 리튬이온배터리를 실험시료로 선정하였다. 고온에 따른 폭발위험성 측정결과 리튬폴리머배터리의 경우 평균 $170^{\circ}C$, 리튬이온배터리의 경우 평균 $187^{\circ}C$에서 폭발이 일어났다. 단락전류에 따른 온도상승측정결과 보호회로가 정상작동 할 경우 과전류를 제한하여 온도상승이 거의 없었지만, 보호회로가 고장 났을 경우 리튬폴리머배터리의 경우 평균 $115.7^{\circ}C$ 및 리튬이온배터리 경우 평균 $80.5^{\circ}C$까지 상승하여 화재 및 화상 위험성이 높게 나타나는 것으로 측정되었다.

어육신선도 측정장치의 개발 (Development of device for the degree of freshness of wet fish)

  • 유휘룡;이남걸;신민생;조영제;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.272-275
    • /
    • 1992
  • Recently, the digital circuit technique has had great success and gained importance in all industries. For the measurement of degree of freshness of plant and animal's tissue, many devices has been developed. But it's data was inaccurate and it had difficulty in making database because it was depend on analog circuit technique. The purpose of this paper is the development of a device based on digital circuit for measurement of freshness degree of wet fish such that its accuracy is very trustworthy and it can be measured in a short time. The device is developed by using micro-computer with some interface modules of A-D/D-A converter and digital circuit with IC modules and its effectiveness has been evaluated through two experimental results of electrical Q-value test and chemical K-value test.

  • PDF

합성 차단 시험용 DC300kV 충전장치 개발 (300kV DC Charging system for Synthetic Testing Facility)

  • 임근희;최영욱;박점문;박경엽;이우영;정진교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1354-1356
    • /
    • 2000
  • This paper deals with a 300kV dc charging system to be used ?s a voltage source in a circuit breaker synthetic short-circuit-test facility. Cockcroft-walton circuit is used to step up the rectified voltage from a single phase transformer of which primary winding is hooked up to an ac220 wall plug. Two systems with the same ratings have been designed and manufactured. The two system have been made of different supporting structure with different insulating materials. The paper describes a couple of charging schemes, system configurations and the synthetic test circuit in which the developed system is to be used.

  • PDF

회전자 저항변화에 따른 고온초전도 단락봉을 사용한 농형유도전동기의 속도-토크 특성 (Speed-torque Characteristics of the Squirrel Cage Induction Motor with High Temperature Superconducting Rotor Bars by the Variation of the Rotor resistance)

  • 심정욱;이광연;차귀수;이지광
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권3호
    • /
    • pp.33-37
    • /
    • 2004
  • This paper presents the construction and test results of an HTS induction motor. End rings and short bars were made of HTS tapes, To increase the efficiency and starting torque, HTS tapes can be used as the rotor bars. Because large current is induced in the rotor circuit, HTS tapes quench and high starting torque can be obtained. As the speed of rotor builds up. HTS tapes which are used as short bars become superconducting state again. After the HTS tapes recover from quench, resistance of the rotor circuit is nearly zero. In that case, power loss in rotor circuit is eliminated. Stator of the conventional induction motor was used as the stator of the HTS motor. Rated capacity of the conventional motor was 0.75 kW. Performances of the HTS induction motor were compared with those of the conventional motor with same volume and specification. Test result showed that the speeds of the HTS induction motor were the same with synchronous speed up to 2.6 Nm and 1.788 rpm at 9.7 Nm. It guarantees the high efficiency of the HTS motor. Starting torque of the HTS motor was more than twice of the conventional motor.