• Title/Summary/Keyword: Short Circuit Test

Search Result 259, Processing Time 0.023 seconds

Consideration on data acquisition and analysis system for using short-circuit tests (디지털 측정 및 분석장치의 적용에 관한 연구)

  • Kim, M.H.;Suh, Y.T.;Kim, D.W.;Kang, Y.S.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.38-40
    • /
    • 2001
  • Measuring technology based on the computer and software is used worldwideiy by the aids of remarkably improved digital technology and measuring devices, and the electro- magnetic interference due to high currents and high voltages is being solved by the helps of applied optic instrumentation technology. The automatic acquisition, analysis and storage system of test data is available for utilizing the numerical computation technology. The measuring accuracy and testing efficiency are thus much higher because of the developed technologies. In this paper, the construction of data acquisition system in KERI including measuring devices and its application to the short circuit test are described, and additionally the algorithm of the analyzing program for the automatic process of test data and the results of analyses are described.

  • PDF

Construction and Circuital Characteristics of Simple Synthetic Test Facility (간이 합성시험설비의 구성 및 회로특성)

  • Lee, J.H.;Park, K.Y.;Chang, K.C.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.168-170
    • /
    • 1995
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. The analyzed results of the circuit which can be useful for the design stage of the testing facility are also shown. EMTP has been used to analyze the circuit. Two cases of short-circuit test results obtained from the simple synthetic testing facility in KERI are shown with the waveforms of current and voltage. The results also indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

A Study on the Development of 25.8kV 25kA Gas Circuit Breaker Using Thermal-Expansion Principle(II) (25.8kV 25kA 열팽창분사식 가스차단기 개발에 관한 연구(II) - 팽창실 용적이 차단성능에 미치는 영향 -)

  • Song, K.D.;Park, K.Y.;Shin, Y.J.;Kim, K.S.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.80-82
    • /
    • 1996
  • This paper deals with the effects of the volume of thermal expansion chamber on the interrupting performance in thermal expansion type 25.8kV 25kA gas circuit breaker. Model interrupters with 5 type thermal expansion chamber were designed and manufactured. Short-circuit tests were carried out for those model interrupters with 25kA breaking current. Pressure rise in the expansion chamber were measured and compared with the calculated one which was obtained from a self-developed program in our team. The analysis on the interrupting performance of each model interrupter has been done on the base of the short-circuit test results.

  • PDF

Characteristics of Vibration Signal in the Transformer before & after Short Circuit Test (단락시험 전.후의 변압기 진동신호 특성)

  • Kang, Chang-Gu;Kim, Hyun-Sik;Kim, Young-Sik;Kim, Jae-Chul;Chung, Chan-Soo;Kwak, Hee-Ro;Joo, Byoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1359-1361
    • /
    • 1995
  • This paper describes the method of diagnosis for power transformer, using vibration signal analysis. Vibration signal to be made from transformer is the liner combination of load current, applied voltage and internal temperature. This study measured the vibration signal by before and after short circuit test of the transformer. And the signal analysis and comparison was carried out for AR modeling and frequency analysis.

  • PDF

Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test (삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션)

  • Lee, Eung-Ro;Lee, Seung-Je;Lee, Chan-Joo;Ko, Tae-Kuk;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

Development of device for the degree of freshness of wet fish (어육신선도 측정장치의 개발)

  • 유휘룡;이남걸;신민생;조영제;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.272-275
    • /
    • 1992
  • Recently, the digital circuit technique has had great success and gained importance in all industries. For the measurement of degree of freshness of plant and animal's tissue, many devices has been developed. But it's data was inaccurate and it had difficulty in making database because it was depend on analog circuit technique. The purpose of this paper is the development of a device based on digital circuit for measurement of freshness degree of wet fish such that its accuracy is very trustworthy and it can be measured in a short time. The device is developed by using micro-computer with some interface modules of A-D/D-A converter and digital circuit with IC modules and its effectiveness has been evaluated through two experimental results of electrical Q-value test and chemical K-value test.

  • PDF

300kV DC Charging system for Synthetic Testing Facility (합성 차단 시험용 DC300kV 충전장치 개발)

  • Rim, G.H.;Choi, Y.W.;Park, J.M.;Park, K.Y.;Lee, W.Y.;Chung, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1354-1356
    • /
    • 2000
  • This paper deals with a 300kV dc charging system to be used ?s a voltage source in a circuit breaker synthetic short-circuit-test facility. Cockcroft-walton circuit is used to step up the rectified voltage from a single phase transformer of which primary winding is hooked up to an ac220 wall plug. Two systems with the same ratings have been designed and manufactured. The two system have been made of different supporting structure with different insulating materials. The paper describes a couple of charging schemes, system configurations and the synthetic test circuit in which the developed system is to be used.

  • PDF

Speed-torque Characteristics of the Squirrel Cage Induction Motor with High Temperature Superconducting Rotor Bars by the Variation of the Rotor resistance (회전자 저항변화에 따른 고온초전도 단락봉을 사용한 농형유도전동기의 속도-토크 특성)

  • Sim Jung-wook;Lee Kwang-youn;Cha Guee-soo;Lee Ji-kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.33-37
    • /
    • 2004
  • This paper presents the construction and test results of an HTS induction motor. End rings and short bars were made of HTS tapes, To increase the efficiency and starting torque, HTS tapes can be used as the rotor bars. Because large current is induced in the rotor circuit, HTS tapes quench and high starting torque can be obtained. As the speed of rotor builds up. HTS tapes which are used as short bars become superconducting state again. After the HTS tapes recover from quench, resistance of the rotor circuit is nearly zero. In that case, power loss in rotor circuit is eliminated. Stator of the conventional induction motor was used as the stator of the HTS motor. Rated capacity of the conventional motor was 0.75 kW. Performances of the HTS induction motor were compared with those of the conventional motor with same volume and specification. Test result showed that the speeds of the HTS induction motor were the same with synchronous speed up to 2.6 Nm and 1.788 rpm at 9.7 Nm. It guarantees the high efficiency of the HTS motor. Starting torque of the HTS motor was more than twice of the conventional motor.