• 제목/요약/키워드: Shoe type

Search Result 122, Processing Time 0.038 seconds

A Study on PBD Improvement Effect depending on disturbance by Laboratory Model Tests failure. (실내 모형시험을 통한 교란에 따른 PBD개량효과 연구)

  • Lim, Jin-Gyu;Kim, Woo-Jin;Hwang, Sung-Won;Kang, Kwon-Soo;Kim, Jong-Ryeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1132-1135
    • /
    • 2008
  • In this study, a circular and indoor soil tank foundation was manufactured to study the improvement according to the degree of turbulence arising from PBD penetration, using the existing plate-type shoe and improved V-type shoe to change the degree of turbulence. Furthermore, to study the foundation improvement effect, the strength, settlement speed in the turbulence area were compared according to the shoe penetration. The results of the study showed that the V-type shoe reduced the strength coefficient decrease effect, and the foundation improvement effect according to the degree of turbulence was identified.

  • PDF

Effects of Shoe Heel-Heights on the Foot Comfort (구두의 굽높이가 발의 쾌적감에 미치는 영향)

  • Kim Hyo Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 1986
  • This paper is concerned with the mutual relationship among interpressure, last. foot within a new shoe and foot within a fifty-hour-used shoe at the standing posture at three different heel-heights 1. The interrelationship between the heel-heights and interpressure is very significant at the level of $0.1\%$. The heel-heights cause high interpressure at different parts of foot; heel point and big toe point in a 3 cm-heel shoe, big toe point and heel outside joint point in a 5 cm-heel shoe, and little toe point, heel-outside joint point, and arch point in a 7 cm-heel shoe. 2. Foot girth and foot width measurements either within a new shoe or within a fifty-hour-used shoe significant at the level of $5\%,\;1\%,\;0.1\%$ and show discrepancies at three different heel heights; the part between instep and ball joint in a 3 cm-heel shoe, toe part in a 5 cm-heel shoe, heel-inside joint. heel-outside joint and toe part in a 7 cm-heel shoe are highly influenced by heel heights. The higher the shoe-hee15 are, the more heavily the fore part of foot is pressured in lateral direction because shoe is made to have high instep from a fashion viewpoint. Higher shoe heels prevent weight pressure from being concentrated on heel. If shoe heels are toe high, people in such shoes feel easily tired. It is very worthy of note in selecting shoes to consider not only the shoe fashion but also fore shoe type, heel height, and shoe material with proper elasticity.

  • PDF

A Survey on the Status of Shoe-last Production for Handmade Shoes - Focused on Seongsu-dong Complex - (수제화 라스트 생산 현황 조사 - 성수동 지역을 중심으로 -)

  • Hong, Eun-Hee;Park, Myung-Ja;Jeong, Jae-Chul;Uh, Mi-Kyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.4
    • /
    • pp.93-104
    • /
    • 2017
  • This study is a basic study to develop shoe last design technology to enhance and revitalize the competitiveness of the handmade shoes. In-depth interviews were conducted with four manufacturers in Seongsu-dong to identify the production status and design technology of shoe lasts. The result of the research is as follows. Firstly, shoe lasts for adults are produced at intervals of 5mm between 245mm-285mm for men's shoes, and between 220-260mm for women's shoes. The production rate of women's shoes was high in the order of general type, boot type, and sandal type while men's shoes mainly produce general type. Secondly, the master last size and ball girth rating for men's and women's shoes were analyzed to EE-EEE grade at 260mm and D grade at 235mm. The length of the master last for men's shoes is 276-290mm, the heel width is 60-65mm, the ball width is 88-90mm, the ball girth is 250mm, and the waist girth is 248mm. The length of the master shoe last for women's shoes is 236-245 mm, the heel width is 50-55mm, the ball width is 78-80mm, the ball girth is 211~213mm, and the waist girth is 213~215mm. Thirdly, the last grading deviation is 5mm in length, the heel width is 0.5mm, the ball girth is 3.5mm, and the ball with is 1.2mm. The ball girth dimensions of Oxford type, slip-on type, and sneakers type are made at 250mm, 248mm, and 245mm for men's shoes. For women's shoes, the ball girth dimensions of pump type, loafer & boot type, and sandal type are made at 211~213mm, 214~215mm, and 211mm. Fourthly, t+he construction of the automation system is insufficient and almost completely depends on manual production.

  • PDF

CFD Analysis on Shoe and Swash-Plate of Axial Piston Pump (사판식 유압펌프의 피스톤 슈 간극의 유동해석)

  • Kim, In-Soo;Lee, Kyong-Hoon;Bae, Jae-Man
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.156-158
    • /
    • 2008
  • Along the various gap distance between shoe and swash plate and pocket diameter, lifting force of piston shoe during the compressing stage was calculated. The flow in piston, orifice, shoe, and back space was considered to be 2-dimension axisymmetric and analysed by Fluent, a commercial CFD Software. The wall boundary condition was given as nonslip and adiabatic, while the change in fluid viscosity was considered as linear along temperature. Calculated lifting force and oil leakage of shoe was used in the design of a pump to confirm the shape of the shoe.

  • PDF

Rear drum brake creak(scratching) noise improvement during braking(or parking apply) (제동시 발생하는 리어 드럼브레이크 creak(scratching) 노이즈 개선)

  • Jang, Myunghoon;Park, Shin;Kim, Sunho;Kim, Sunghwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.486-491
    • /
    • 2013
  • Creak noise is kind of scratching noise which is usually generated in drum brake system on the vehicle. When driver brakes vehicle or applies parking lever, drum brake shoe moves to the drum side to stop the vehicle. And at that time, moving shoe scratches backing plate ledge surface, and that makes scratching noise in special condition. This study presents how we can generate creak noise in the laboratory and how we can reduce it by experimental approach. Through several and various type of tests, we could generate creak noise with damage on ledge area of the backing plate in the lab and we verified tab type shoe design can reduce this scratching noise. As a result of this study, we notified how creak noise happens in the vehicle, and that tab type design shoe has good performance of ledge area damage based on lab test(rig & dynamometer equipment), and that this can reduce potential risk of creak noise in the field.

  • PDF

Foot discomfort by foot shape, shoe design and wearing attitude (발의 형태, 구두 디자인, 구두 착용태도에 따른 발의 불편감)

  • Moon, Eun-Mi;Sang, Jeong Seon;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.4
    • /
    • pp.117-130
    • /
    • 2018
  • As women wear shoes for a long time due to aesthetic elements and working environment, many women experience discomfort and deformation in their feet due to their shoes and the production of comfortable shoes is becoming an important issue. The purpose of this study is to investigate the factors affecting the grip of shoes by foot type, shoe design, and wearing attitude of shoes. Through this, we suggest solutions for foot discomfort due to wearing shoes and help to prevent foot related diseases. The study results are as follows; first, a wide foot, square-type, and high or low arch (hollow foot or flat foot) among foot shapes influenced the fatigue and pain of feet, and big feet over 250mm-long, wide feet, square-type feet, and high-arch feet (hollow foot) had an influence on distortion and side effects. Second, among the characteristics of wearing shoes influencing foot discomfort, the higher the shoe heels were, the narrower the surface covering the feet was (pumps and mule), and the shoes with high front heels and narrow back heel area, the shoe wearer had a higher possibility of experiencing fatigue and pain and even had not only fatigue and pain but also side effects when she wore pointed shoes. Third, a shoe wearer experiences fatigue and pain if she wears shoes for a shorter period of time, stay stood while wearing shoes for a short time, and wears shoes that are bigger or smaller than the actual shoe size. Fourth, fatigue and pain experiencers and distortion and side effects experiencers all responded that they change into other shoes to deal with foot discomfort and that they directly massage their feet.

A Study on the Rolling Friction Characteristics of Large Scale Roller Shoe for Bridge Supporter (교량받침용 대형 Roller Shoe의 구름마찰특성에 관한 연구)

  • 김영득;김재철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.660-663
    • /
    • 2001
  • There is a mechanical device between the superstructure and substructure of a bridge, which transmit vertical load of superstructure to the substructure and absorb horizontal displacement of super structure due to thermal, dynamic, load, etc. In order to meet two requirements at once, the structure of roller between plates is widely used, and this roller between plates is widely used, and this roller shoe system is known to have smaller horizontal movement resistance than any other type of bridge shoe. In this study, rolling friction resistance characteristics of roller-plate friction system is investigated according to roller dimension, vertical load, hardness and roughness of roller and plate. On the base of the results, the rolling friction resistance of large scale roller shoe is evaluated using model experiment.

  • PDF

Kinematics and Kinetics of the Lower Limbs of a Walking Shoe with a Plate Spring and Cushioning Elements in the Heel during Walking

  • Park, Seung-Bum;Stefanyshyn, Darren;Pro, Stergiou;Fausto, Panizzolo;Kim, Yong-Jae;Lee, Kyung-Deuk
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • The purposes of this study was to investigate the biomechanical influence of the walking shoe with a plate spring in the heel and interchangeable heel cushioning elements. Eighteen subjects walked in three conditions: 1) the walking shoes Type A-1 with a soft heel insert, 2) the Type A-2 shoe with a stiff heel insert, 3) a general walking shoe(Type B). Ground reaction forces, leg movements, leg muscle activity and ankle, knee and hip joint loading were measured and calculated during overground walking. During walking, the ankle is a few degrees more dorsiflexed during landing and the knee is slightly more flexed during takeoff with the Type A shoes. As a result of the changes in the walking movement, the ground reaction forces are applied more quickly and the peak magnitudes are higher. Muscle activity of the quadricep, hamstring and calf muscles decrease during the first 25% of the stance phase when walking in the Type A shoes. The resultant joint moments at the ankle, knee and hip joints decrease from 30-40% with the largest reductions occurring during landing.

The Effects of Shoe Type on Ground Reaction Force

  • Yi, Kyung-Ok
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • The purpose of this study is to analyze the effects of both various shoe types and bare feet on ground reaction force while walking. Ten first-year female university students were selected. A force platform(Kistler, Germany) was used to measure ground reaction force. Six types of shoe were tested: flip flops, canvas shoes, running shoes, elevated forefoot walking shoes, elevated midfoot walking shoes, and five-toed shoes. The control group was barefooted. Only vertical passive/active ground reaction force variables were analyzed. The statistical analysis was carried out using the SAS 9.1.2 package, specifically ANOVA, and Tukey for the post hoc. The five-toed shoe had the highest maximum passive force value; while the running shoe had the lowest. The first active loading rate for running shoes was the highest; meanwhile, bare feet, the five-toed shoe, and the elevated fore foot walking shoe was the lowest. Although barefoot movement or movement in five toed shoes increases impact, it also allows for full movement of the foot. This in turn allows the foot arch to work properly, fully flexing along three arches(transverse, lateral, medial), facilitating braking force and initiating forward movement as the tendons, ligaments, and muscles of the arch flex back into shape. In contrast movement in padded shoes have a tendency to pound their feet into the ground. This pounding action can result in greater foot instability, which would account for the higher loading rates for the first active peak for padded shoes.

A Study on the Therapeutic Shoes for Diabetic Patients (당뇨병 환자의 치료용 신발에 대한 연구)

  • Lee, Woo-Chun;Park, Sung-Sik
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.16-21
    • /
    • 2004
  • Purpose: To investigate the characteristics of the patients and therapeutic shoes for diabetic patients. Materials and Methods: Forty two diabetic patients who had their own therapeutic shoes which were prescribed somewhere else were studied from March 2003 to December 2003. There were 27 males and 15 females, and the mean age was 62.1 years (range, 49-72 years). Duration of diabetes was average 14 years (range, $6{\sim}30$ years), all had type 2 diabetes. Sensation was examined with 5.07 nylon monofilament. The route of purchasing the shoes, compliance to the prescribed shoes were investigated by interview. The shape of shoe, stiffness of upper, conformity of insole to the shape of the foot were recorded. In-shoe plantar pressure was measured in 15 patients. Results: Eighteen patients were insensate to the monofilament. Seven patients did not wear the therapeutic shoes, and only 18 of 35 patients were wearing the therapeutic shoes more than 6 hours a day. The shoes of 17 patients were prescribed by medical doctor and the rest were purchased by the recommendation of acquaintances or advertisement. Ulcer recurred in four of five patients to whom the shoe was prescribed by medical doctor and the cause of three recurrences were evident by just observing the foot and shoe. The therapeutic shoes were made from 11 different makers. Eight shoes were adequate for diabetic patients with respect to the material, shape of insole, type of shoe. In-shoe plantar pressure was examined in 15 patients and was less than 300 kPa in all patients. Conclusion: The therapeutic shoes for the diabetic patients need to be prescribed by medical doctor for selective patients with neuropathy or previous history of ulcer and follow-up examination is important to monitor the compliance of the patients and adequacy of the shoes.

  • PDF