• Title/Summary/Keyword: Shock reliability

Search Result 216, Processing Time 0.029 seconds

Estimation of the Pipe Thickness using the Variation of the Group Velocity (군속도 변화를 이용한 배관 두께 측정)

  • Han, Seung-Hee;Hwang, Jong-Myung;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.1
    • /
    • pp.32-40
    • /
    • 2010
  • This paper proposes the technique of estimating the pipe thickness using the measured group velocity. To measure the group velocity from the accelerometer data in the frequency domain, Wigner-Ville distribution is utilized, which interprets the waveform of the shock wave. Using this measured group velocity, this paper proposes the technique to estimate the thickness of pipes with the impact on the pipe. The group velocity is estimated by the modeling correlation between the group velocity and the thickness of the pipe based on the propagation velocities. The correlation model between thickness and group velocity has been proved through the real experiments. The measured group velocity in the frequency-domain is the maximum at the center frequency of the bending waves in the modeling of the group velocity. In addition to these, a smoothing technique for analyzing lamb wave Wigner-Ville distribution has been introduced to improve the reliability of the data acquisition.

LAUNCH ENVIRONMENTAL TEST FOR KITSAT-3 FM (우리별 3호 비행모델에 대한 발사환경시험)

  • 이상현;장영순;배정석;이동우;정연황;성단근
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.1
    • /
    • pp.79-88
    • /
    • 1999
  • The satellite experiences the severe launch environment such as vibration, acceleration, shock, and acoustics induced by rocket. Therefore, the satellite should be designed and manufactured to endure such severe launch environments. In this paper, we describe the structure of the KITSAT-3 FM(Flight Model) and the processes and results of the launch environmental test to ensure the reliability during launch period.

  • PDF

Gate Leakage Current Characteristics of GaAs MESFETS′ with different Temperature (GaAs MESFET의 온도변화에 다른 게이트 누설전류 특성)

  • 원창섭;김시한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.50-53
    • /
    • 2001
  • In this study, gate leakage current mechanism has been analyzed for GaAs MESFET with different temperatures ranging from 27$^{\circ}C$ to 300$^{\circ}C$ . It is expected that the thermionic and field emission at the MS contact will dominate the current flow. Thermal cycle is applied to test the reliability of the device. From the results, it is proved that thermal stress gradually increases the gate leakage current at the same bias conditions and leads to the breakdown and failure mechanism which is critical in the field equipment. Finally the gate contact under the repeated thermal shock has been tested to check the quality of Schottky barrier and the current will be expressed in the analytical from to associate with the electrical characteristics of the device.

  • PDF

Effect of sintering process on the electrical protection performance in a ZnO-based ceramic varistor (ZnO varistor의 소결온도와 첨가물혼합비가 전기적 보호특성에 미치는 영향)

  • 오명환;이경재
    • 전기의세계
    • /
    • v.31 no.6
    • /
    • pp.445-449
    • /
    • 1982
  • This Paper describes the influence of additive concentrations and sintering temperature on the surge protection performance in ZnO ceramic varistors. It is found from the experiments that the metal-oxide semiconductors based oi ZnO with an additive incorporation of 0.50% molx(Bi$\_$2/O$\_$3/+MnO+CoO+Cr$\_$2/O$\_$3/+2Sb$\_$2/O$\_$3/) and sintered at 1250.deg. C present excellent V-I characteristics in view of transient surge suppression. Gapless arrester element with aluminum electrodes shows also good reliability against impulse shock and marks a low voltage clamping ratio(V$\_$1KA/V$\_$1mA/<2.0) compared with the conventional SiC varistors.

  • PDF

Dynamic Response Assessment of Space Use Telescope (우주용 광학구조체의 진동응답 평가)

  • Cho, Hee Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.87-93
    • /
    • 2015
  • The dynamic responses of a telescope loaded on an STSAT-3 satellite were analyzed, and environmental tests were conducted to verify the reliability of the design. The space use telescope COMIS (compact imaging spectrometer) is a major payload of the STSAT-3 launched on November 21, 2013. Vibration responses such as the acceleration, displacement, and velocity with respect to random vibration and shock impulse inputs were obtained based on theoretical fundamentals in conjunction with finite element analysis. The main focus of this study was on developing technology for accurate and/or favorable modeling and analysis of the structure and fitting the results to that of experiments. Cutting-edge technology for manipulating the vibrations of a space use telescope is suggested.

Structural Analysis of Boiler Module for Sea-Transportation (해상 운송을 위한 보일러 모듈의 구조 해석)

  • Jeon, Y.C.;Kim, T.W.;Jeong, D.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.788-793
    • /
    • 2001
  • Finite element analysis was carried out to investigate the integrity and reliability of boiler module during sea transportation. The boiler module was supported by steel structure to relieve the instantaneous shock from oceanic wave and its primary parts were strengthened with several reinforcements. Finned tube walls which were used in the furnace wall were assumed as orthotropic plates having equivalent material properties. The bank tubes were also equivalently modeled in accordance with ASME B31.1 for the convenience of finite element modeling. The calculation results were compared with the yield stress of the material. In particular, the bank tube stress, which was evaluated by converting the calculated stresses in equivalent tubes into those in original tubes by using the ratio of diameter, was also examined with yield stress.

  • PDF

The Shape Optimization of TCP to Reduce the Line Defects of LCD Module (액정 디스플레이(LCD)의 선 결함 발생 저감을 위한 TCP 형상 최적화)

  • Park, Sang-Hu;Lee, Bu-Yun;Kim, Won-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.140-145
    • /
    • 2001
  • The tape carrier package(TCD) is one of the most important components in a liquid crystal display(LCD) module. It has a role to transmit electrical signals from a printed circular board(PCB) to a display panel. If TCP is damaged under mechanical shock, the signals can not be transmitted to the panel and as a result, some dead lines are generated on the panel. This kind of phenomenon is commonly called as 'line defects'. In this paper, new structural design concepts of TCP are proposed to guarantee its reliability by using Taguchi's approach and dynamic FE-analysis. The line defects problem of TCP module is solved by replacing the original TCP with the newly designed one.

  • PDF

Useful Lifetime Prediction of Coupling Rubber Pad for Railway Vehicles (철도차량 완충기 패드용 고무소재 수명예측)

  • Woo, Chang-Su;Park, Hyun-Sung;Park, Dong-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.923-931
    • /
    • 2008
  • Coupling rubber pad are important components in railway vehicles. It can be used for reduce shock, vibration and noise. Simple tension, equi-biaxial tension and pure shear test were performed to acquire the coefficient of rubber material which were Mooney-Rivlin and Ogden model. The finite element analysis was executed to evaluate the behavior of deformation and stress distribution by using the commercial finite element analysis code. Useful life evaluation are very important in design procedure to assure the safety and reliability of the rubber components. In this paper, useful life prediction of rubber pad for railway vehicle were experimentally investigated. Accelerated heat-aging test for rubber material were carried. Compression set results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot.

  • PDF

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

High Impedance Fault Detection Using Neural Networks (신경회로망을 이용한 고저항 고장 검출)

  • Han, J.G.;Lee, H.S.;Yun, J.Y.;Yang, K.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.465-467
    • /
    • 1995
  • High impedance fault can not be easily detected by conventional method. But if it would not be detected and cleared quickly, it can result in fires, and electric shock. In this paper, ANN, which has learning capability, is used for high impedance fault detection. The potential of the neural network approach is demonstrated by simulation using KEPCO's measured data. Among ANN models used in this paper, CPN shows better result than BPN in respect of convergence and reliability.

  • PDF