• 제목/요약/키워드: Shih-tzu bitches

검색결과 14건 처리시간 0.016초

소형 애완견에서 초음파 검사에 의한 임신 구조물의 최초 관찰 시기 (Time of Initial Detection of the Gestational Structures by Ultrasonography Examination in Small Pet Dogs)

  • 박상국;김방실;윤창진;여운창;박철호;김재풍;이숙경;문진산;서국현;오기석;손창호
    • 한국수정란이식학회지
    • /
    • 제23권1호
    • /
    • pp.5-11
    • /
    • 2008
  • Serial ultrasonographic examinations were daily performed from 15 days after ovulation until parturition to determine the time of first detection and ultrasonographic appearance of the fetal and extra-fetal structures in pregnant 10 Maltese, 10 Yorkshire Terrier, 15 Shih-tzu, and 10 Miniature Schnauzer bitches, respectively. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0ng/ml. The gestational length was $63.4{\sim}63.6$ (range: $61{\sim}65$) days and the geatational length was no statistically significant difference among bitches (p>0.05). The initial detection of the extra-fetal structures were; gestational sac at days $18.9{\sim}19.5\;(17{\sim}22)$, zonary placenta at days $24.6{\sim}25.5\;(23{\sim}28)$, yolk sac membrane at days $24.6{\sim}25.5\;(23{\sim}27)$, yolk sac tubular shape at days $26.1{\sim}26.3\;(24{\sim}28)$, and amniotic membrane at days $26.1{\sim}28.2\;(24{\sim}31)$, respectively. The time of the first detection of the extra-fetal structures were no statistically significant difference among bitches (p>0.05). The initial detection of the fetal structures were; embryo initial detection at days $22.5{\sim}22.9\;(21{\sim}24)$, heartbeat at days $23.2{\sim}23.8\;(21{\sim}25)$, embryo bipolar shape $27.6{\sim}28.9\;(26{\sim}30)$, fetal movement at days $31.9{\sim}32.8\;(27{\sim}34)$, limb buds at days $29.1{\sim}30.7\;(27{\sim}33)$, stomach at days $31.1{\sim}33.1\;(29{\sim}34)$, urinary bladder at days $32.4{\sim}33.2\;(29{\sim}35)$, skeleton at days $34.7{\sim}35.9\;(34{\sim}39)$, and kidney at days $42.1{\sim}44.7\;(41{\sim}48)$, respectively. The the time of the first detection of the fetal structures were no statistically significant difference among bitches (p>0.05). These results indicate the evaluation of the time of first detection and ultrasonographic characteristics of the gestational structures might be useful for pregnancy diagnosis, estimating fetal age, embryonic resorption, fetal monster, abnormal fetal growth and fetal viability, respectively.

소형 애완견에서 초음파 검사에 의한 분만일 예시표의 확립 (Establishment of a Prediction Table of Parturition Day with Ultrasonography in Small Pet Dogs)

  • 오기석;김방실;박상국;박철호;김재홍;문병권;김희수;이주환;박인철;김종택;서국현;손창호
    • 한국수정란이식학회지
    • /
    • 제23권3호
    • /
    • pp.155-160
    • /
    • 2008
  • Serial ultrasonographic examinations were performed to establish a prediction table of parturition date in pregnant Maltese, Yorkshire Terrier, Shih-tzu and Miniature Schnauzer bitches. The inner chorionic cavity diameter and fetal head diameter in 45 pregnant bitches were converted retrospectively based on the day of parturition. The data of inner chorionic cavity diameter obtained from Day-44 to Day-25 and fetal head diameter obtained from Day-25 to Day-1 were used to compile a equations of prediction of parturition date. The 70 pregnant bitches with unknown mating time were examined to assess an accuracy of the equations established in this study. And these results were applied to the prediction of parturition date and compared to actual parturition date. The accuracy for parturition date within 0, $\pm$1, and $\pm$2 days interval using the equations of prediction of parturition date were 64.3%, 22.8% and 12.8%, respectively. The overall accuracy of prediction table of parturition day based on the ICCD and HD was 100% accurate within $\pm$2 days. Therefore, the prediction table seems to be a useful tool of the prediction of parturition day in practice.

소형 애완견에서 초음파 검사에 의한 임신 구조물의 성장 곡선 (Growth Curve of the Gestational Structures by Ultrasonography Examination in Small Pet Dogs)

  • 오기석;김방실;박상국;박철호;김재홍;문병권;김희수;이주환;박인철;김종택;서국현;손창호
    • 한국수정란이식학회지
    • /
    • 제23권3호
    • /
    • pp.147-153
    • /
    • 2008
  • Serial ultrasonographic examinations were daily performed from 15 days after ovulation until parturition to determine the growth curve of gestational structures in pregnant Maltese, Yorkshire terrier, Shih-tzu, and Miniature Schnauzer bitches, respectively. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0 ng/ml. The inner chorionic cavity diameter were significantly and linearly relative to gestational age especially days 20 to 40, and the fetal head diameter were significantly and linearly relative to gestational age especial1y day 40 to parturition. These results indicate that inner chorionic cavity diameter were the most accurate for estimating gestational age before day 38 of gestation and the fetal head diameter were after day 38 of gestation.

Ultrasonography, Affected Age, Hematology and Clinical Signs according to Open or Closed Cervix in Dogs with Pyometra

  • Lee, Jun-Am;Kim, Ill-Hwa;Hwang, Dae-Youn;Kang, Hyun-Gu
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.362-367
    • /
    • 2016
  • The aim of the study was to evaluate ultrasonographic findings, affected age, hematology, blood chemistry and clinical signs according to open or closed cervix in 102 bitches presented for treatment of pyometra. The prevalence of pyometra according to breed was observed in Maltese 22.5%, Yorkshire Terrier 13.7% and Shih Tzu 12.7%. The mean age of dogs was $9.6{\pm}0.3years$, and open cervix pyometra was more prevalent than closed cervix pyometra. Clinical signs included anorexia, vaginal discharge, depression, polyuria/polydipsia, vomiting, and abdominal distension. The concentration of BUN and the activity of ALP in dogs with closed cervix pyometra were significantly higher than those in dogs with open cervix pyometra (p < 0.05). The white blood cell and neutrophils in dogs with closed cervix pyometra were significant higher than those in dogs with open cervix pyometra (p < 0.05). Ultrasonographic findings of the uterus with open or closed cervix pyometra showed variable patterns. The uterine wall was variable in appearance, from thick and irregular to smooth and thin. The uterine wall was thicker in open cervix pyometra than in closed cervix pyometra. The luminal cavity included smaller amount of anechoic fluid in open cervix pyometra than in closed cervix pyometra.