• Title/Summary/Keyword: Shield Materials

Search Result 244, Processing Time 0.028 seconds

Development of Shielding using Medical Radiological Contrast Media; Comparison Analysis of Barium Sulfate Iodine Shielding ability by Monte Carlo Simulation (의료방사선 조영제를 이용한 차폐체 개발; 몬테카를로 시뮬레이션을 통한 황산바륨과 요오드의 차폐능 비교분석)

  • Kim, Seon-Chil
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.329-334
    • /
    • 2017
  • The purpose of this study is to estimating the possibility of manufacturing radiation shielding sheet by searching for environmentally friendly materials suitable for medical environment of medical radiation shielding. There are many tungsten products which are currently used as shielding materials in place of lead, but there are small problems in the mass production of lightweight shielding sheets due to economical efficiency. To solve these problems, a lightweight, environmentally friendly material with economical efficiency is required. In this study, Barium sulphate and Iodine were proposed. Both materials are already used as contrast medias in radiography, and it is predicted that the shielding effect will be sufficient in a certain region as a shielding material because of the characteristic of absorbing radiation. Therefore, in this study, we used a Monte Carlo simulation to simulate radiation shielding materials. When it is a contrast agent such as Barium sulfate and Iodine, the radiation absorption effect in the high energy region appears greatly, and the effectiveness of the two shielding substance in the energy region of the star with thickness of 120 kVp is also evaluated in the medical radiation imaging region. Simulated estimation results it was possible to estimate the effectiveness of shielding for all two substances. Iodine has higher shielding effect than barium sulfate, 0.05 mm thick appears great effect. Therefore, the Monte Carlo simulation confirms that iodine, which is a radiological contrast agent, is also usable as barium sulfate in the production of radiation shielding sheets.

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

Lead-free inorganic metal perovskites beyond photovoltaics: Photon, charged particles and neutron shielding applications

  • Srilakshmi Prabhu;Dhanya Y. Bharadwaj;S.G. Bubbly;S.B. Gudennavar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1061-1070
    • /
    • 2023
  • Over the last few years, lead-free inorganic metal perovskites have gained impressive ground in empowering satellites in space exploration owing to their material stability and performance evolution under extreme space environments. The present work has examined the versatility of eight such perovskites as space radiation shielding materials by computing their photon, charged particles and neutron interaction parameters. Photon interaction parameters were calculated for a wide energy range using PAGEX software. The ranges of heavy charged particles (H, He, C, N, O, Ne, Mg, Si and Fe ions) in these perovskites were estimated using SRIM software in the energy range 1 keV-10 GeV, and that of electrons was computed using ESTAR NIST software in the energy range 0.01 MeV-1 GeV. Further, the macroscopic fast neutron removal cross-sections were also calculated to estimate the neutron shielding efficiencies. The examined shielding parameters of the perovskites varied depending on the radiation type and energy. Among the selected perovskites, Cs2TiI6 and Ba2AgIO6 displayed superior photon attenuation properties. A 3.5 cm thick Ba2AgIO6-based shield could reduce the incident radiation intensity to half its initial value, a thickness even lesser than that of Pb-glass. Besides, CsSnBr3 and La0.8Ca0.2Ni0.5Ti0.5O3 displayed the highest and lowest range values, respectively, for all heavy charged particles. Ba2AgIO6 showed electron stopping power (on par with Kovar) better than that of other examined materials. Interestingly, La0.8Ca0.2Ni0.5Ti0.5O3 demonstrated neutron removal cross-section values greater than that of standard neutron shielding materials - aluminium and polyethylene. On the whole, the present study not only demonstrates the employment prospects of eco-friendly perovskites for shielding space radiations but also suggests future prospects for research in this direction.

An experimental study on the improving noise characteristic of hydraulic power unit (유압동력 발생장치의 소음특성 개선을 위한 실험적 연구)

  • Lee, Gi Chun;Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.638-643
    • /
    • 2013
  • Nowadays, the hydraulic power unit (HPU) has been increased its working pressure and enlarged its capacity in order to improve the performance of the hydraulic system, but it produces noise leveled around 110dB(A) during operation. Recently, due to the reinforcement of industrial safety regulations and the requirement of improving work environment, a separated HPU room is installed at outside or underground of the building as to reduce the noise from HPU, but there are also problems of power loss owing its fluid friction of pipe system and of deficient accessibility during its failure accident. In this study, experiment is performed to improve the noise characteristics with installing a soundproof chamber to minimize the power loss and exclude effectively the high leveled noise, which is generated during the power conversion of HPU.

Friction Characteristics of Aluminized Polyester Fabric under Dry - and Water- Lubricated Conditions

  • Byun, JaeYoung;Okechukwu, Nicholas Nnaemeka;Lee, Eunsuk;Park, JinGyu;Choi, WonSik
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.396-402
    • /
    • 2019
  • Materials made from plastics are increasingly utilized in constructing greenhouses and setting up shield structures. Polyester fabrics have a wide range of use in horticulture and other fields of agriculture. They are utilized as a greenhouse cover and also help in combating intense climate variation in the field. Over time, these fabrics may experience friction against other surfaces. Owing to this, the surface framework of the material degenerates. This study examines the frictional characteristics of aluminized polyester fabric in both dry- and water-lubricated environments under changing applied loads and sliding speeds. Friction experiments are performed at room temperature by employing a pin on a disk. The experiments reveal that the friction coefficient decreases with increase in applied load in both dry sliding and water-lubricated environment. However, the friction coefficient decreases more under the water-lubricated setting than in the dry state. At the maximum applied load, the highest friction coefficient is discovered in the dry state with a range of 0.282 to 0.237, whereas a friction coefficient of 0.229 to 0.189 is observed in the water-lubricated state. Additionally, it is observed that the friction coefficient increases with an increase in sliding speed under both experimental environments. The examination of specimen surfaces reveals that the abrasion is minor in the water-lubricated setting compared with that in the dry state.

Structure movement-coping Waterproofing technology application for Railroad facilities (철도시설에 있어서의 구조물 거동대응형 방수기술의 적용)

  • Cho, Il-Kyu;Lee, Jong-Yong;Oh, Sang-Keun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1964-1969
    • /
    • 2010
  • Recently, as construction market scale is getting bigger and transportation industry is developing, the underground structure construction such as subway, tunnel (excavation box) or shield tunnel structure is becoming more diverse, and its demand is gradually increasing. However, for the concrete structures constructed underground, the water leakage is occurred due to the expansion joint and construction joint, or movement, uneven settlement, excessive load and vibration during application causing cracks. Many waterproofing method and materials are used in jobsites, but areas such as underground railroad and subway that has movement and vibration at all times, the ability of waterproofing layer is declined causing repetitive water leakage due to crack, erosion and separation, which is a vicious cycle. Therefore, this study evaluates the responsiveness to a movement for adhesive/flexible waterproofing material that can cope with the vibration and the movement of the structure. Also to recommend a waterproofing technology that can cope with structure movement through examples of actual jobsite applications such as subway and tunnel where there are constant movement and vibration.

  • PDF

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

A Study on New Shielding Method for Minimizing Thyroid Oran Dose on Chest Radiography Used Automatic Exposure Control (자동노출조절장치를 이용한 흉부 방사선검사 시 갑상샘 장기선량 최소화를 위한 새로운 차폐 방법에 관한 연구)

  • Joo, Young-Cheol;Hong, Dong-Hee;Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.323-329
    • /
    • 2020
  • The purpose of this study is to investigate the effect of radiation shielding on the thyroid organ dose and image quality during Chest PA examination using automatic exposure control system. This study was conducted in the patient posture and examination conditions such as Chest PA using human model phantom. An experiment without shielding was set as a control group (non) and the cases of using paper coated with a contrast agent (contrast) and bismuth (bismuth) were used as experimental groups. Compared to non-shielded(non), the dose at bismuth increased about 7% in C(cervical vertebrae)5 and C6 and 14% in C7 and contrast showed dose increases of about 17 to 19% in C5 and C6 and about 21% in C7. As a result of the image quality comparison, when measured in the center of the cervical vertebrae, both SNR and CNR in bismuth increased about 40% higher than non, and contrast showed about 8 to 9% improvement. Compared with soft tissues of the cervix, bismuth reduced SNR by about 15% and CNR by about 13%, in contrast, SNR decreased by 11%, and CNR decreased by about 10%. In the Chest PA using AEC, the method of using the shield in front of the collimator has the advantage to observe the anatomical structure of the neck area well compared to the method using the lead. However, the dose at the neck can be increased by 7-21% depending on shielding materials.

Dose-Rates Evaluation on a Reinforced Hot Cell facility (핫셀시설의 방사선 안전성 평가)

  • 조일제;국동학;구정회;정원명;유길성;이은표;박성원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.584-589
    • /
    • 2003
  • The hot cell facility which is designed to permit safe handling of source materials with radioactivity levels up to 1,385 TBq, is planned to be built. To meet this goal, the facility is designed to keep gamma and neutron radiation lower than the recommended dose-rate in normally occupied areas. The calculations performed with QAD-CGGP and MCNP-4C are used to evaluate the proposed engineering design concepts that would provide acceptable dose-rates during a normal operation in hot cell facility. The maximum effective gamma dose-rates on the surfaces of the facility at operation area and at service area calculated by QAD-CGGP are estimated to be $2.10{\times}10^{-3}$, $2.97{\times}10^{-2}$ and $1.01{\times}10^{-1}$ mSv/h, respectively. And those calculated by MCNP-4C are $1.60{\times}10^{-3}$, $2.99{\times}10^{-3}$ and $7.88{\times}10^{-2}$ mSv/h, respectively The dose-rates contributed by neutrons are one order of magnitude less than that of gamma sources, and penetration and toboggan will be partly reinforced by lead shield.

  • PDF

A Study on the Geotechnical Property caused by Contact Volume between Weathered Soils and Moisture Sensor for Application of Field Monitoring (현장 모니터링 적용을 위한 풍화토와 함수비센서의 접촉체적에 따른 지반물성 연구)

  • Kim, Man-Il;Chae, Byung-Gon
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.311-319
    • /
    • 2008
  • Evaluation of an amplitude domain reflectometry (ADR) type soil moisture sensor as ThetaProbe ML2x using the response of frequency impedance was performed in a variety of soil porous media such as Jumunjin standard sand, weathered granite soil at Sangju area, and weathered gneiss soil at Jangsu area. The tested soils were classified with a dried condition and a wetted condition for comparing with soil volumetric water content under different installed depths of the measurement sensor. In the results the part of measurement rod including one signal rod and three shield rod 6cm in length was found to decrease the variation of measurement output voltage with insert 5cm over into the soil porous media. The measurement output voltage was verified to more stable output voltage under weathered granite soils and weathered gneiss soils contained the fine grain materials such as clay and silt minerals than the gradual grain material like as the standard sands. Therefore, measurement values by soil moisture sensor can be offered the more stable values when an contact volume between soil porous media and measurement sensor increase.