• Title/Summary/Keyword: Shield Effects

Search Result 152, Processing Time 0.019 seconds

The Effects of Increased Temperature on Yield Properties, Antioxidant Contents, and Pollen Viability of Adzuki Bean (Vigna angularis L.) Responses in Temperature Gradient Greenhouse and Growth Periods (온도구배온실에서 온도상승이 생육시기별 팥의 수량, 항산화 성분, 화분 임성에 미치는 영향)

  • Eun Ji Suh;Ok Jae Won;Jae-Sung Park;Won Young Han;Jin Hee Seo;Sun Tae Kim;Hye Rang Park
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.2
    • /
    • pp.47-58
    • /
    • 2023
  • The quality and yield of crops produced using field cultivation are expected to decrease due to the recent global climate change caused by extreme weather. The plant reproductive stage associated with crop yields is a highly vulnerable period to global warming caused by high temperatures. This study analyzed the adzuki bean's yield properties, antioxidant contents, and pollen viability of adzuki bean (Vigna angularis L.) under high-temperature stress and growth periods in a temperature gradient greenhouse that forms 0 to 4℃ above the outside temperatures. As the main variety of red beans cultivated in Korean farms, the "Arari" red bean was grown in the rain shield greenhouse and the temperature gradient greenhouse from 2021 to 2022 in Milyang, Korea. Compared to 2022, it showed a 0 - 1.0℃ lower temperature during the whole growth period in 2021. However, its average temperatures were 0 - 3.7℃ higher in the vegetative stage and 0.4 - 2.4℃ higher in the anthesis stage in 2021. The lowest yield (6.8 ± 0.7 g) was at the highest temperature (T4: low, 23.6℃; average, 28.5℃; high, 35.8℃) during the anthesis stage in 2021. The temperatures of the mature stage were 1.7 - 3.9℃, which were higher in 2022 than in 2021, although the low temperatures of 2022 were lower than in 2021. The yields of the mature stage in 2022 increased more than in 2021 because of the high temperature of the mature stage. The growth and yield were good at 40.5℃ in the vegetative stage. However, growth was poor when the average temperature was 27.0℃ or higher, and yields decreased during the flowering period. Total polyphenol and flavonoid contents were increased, and the pollen viability was 40.75% in the whole growth period at high temperature (T4: low, 22.9℃; average, 28.8℃; high, 36.9℃). These results showed that the antioxidant levels increased when the antioxidant component was affected at higher temperatures than at normal. In contrast, the pollen viability-related yield decreased as the temperature increased. Our results are the basic data for field growers and the breeding of thermos-tolerance in adzuki beans to prepare for the changeable future climate.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.