• Title/Summary/Keyword: Shield

Search Result 1,460, Processing Time 0.029 seconds

Analysis of Gwonbeop(拳法) in traditional martial arts literature (전통무예서의 권법 분석)

  • Kwak, Nak-hyun;Lim, Tae-hee
    • (The)Study of the Eastern Classic
    • /
    • no.54
    • /
    • pp.289-318
    • /
    • 2014
  • The purpose of this study was to compare Gwonbeop motions among "Gihyosinseo", "Mubiji", "Muyejaebobunyuksokjib" and to analysis catalogue of books on Gwonbeop for comprehensive interpretation in "Muyedobotongji". the conclusion through literature review was as follows. First, There were total 16 references which were composed of 14 references of China and 2 references of Korea. In particular there was no reference of Japan for Gwonbeop. In detail, unrepresentative references of China were "Hanseo", "Gihyosinseo", "Mubiji" and unrepresentative reference of Korea was Muyejaebobunyuksokjib". Second, We compared motions of Gwonbeop between China and Korea. There were located 5 motions such as Gyungakguheese(False Prey Posture), Gigose(Flag Beating Posture), Ahnshichukshinse(Goose Wing Posture), Jumjoose(Picking Elbow Posture), Pogase(Throwing Shelf Postere). In other three references unmentioned "Mubiji" there were located 8 motions such as Jungranse(Spring Railing Posture), Gichukgakse(Ghost Kicking and Leg Striking Postere), Jidangse(Open Finger Attacking Posture), Soodoose(Beast Head Shield Posture) Shingwon(Heavenly Fist Posture), Il-jopyunse(Whipping Lunging Posture), Jakjiryongse(Dragon Prey Snatching Posture), Joyangsoose(Slanting Hero Hand Posture), In two references of Korea there were located 2 unique motions such as Nachaluichoolmun Gakabyunhase(Low Encountering Posture), Gumgyedongnipse(Single Leg Throwing Postere). Third, Most of all we found two kinds of unique motions such as Chukcheonse and Eungswaeik on "Muyejaebobunyuksokjib" and such as Nachaluichoolmun Gakabyunhase(Low Encountering Posture), Gumgyedongnipse (Single Leg Throwing Postere) on "Muyedobotongji". Based on chronological table although "Gihyosinseo" is the longest literature, there was begun changing techniques in details on literatures of Korea. Transformed into techniques of Gwonbeop on Korea could be supposed that those skills were reflected in society and culture of the Joseon Dynasty. To sum it up, Gwonbeop of "Muyedobotongji" was written by "Gihyosinseo", "Mubiji", "Muyejaebobunyuksokjib" but most motions of Gwonbeop were begun to change gradually except 5 motions of "Gihyosinseo". Especially, there were 8 unique motions which could not be found in references of China. Those unique motions of Korea literatures were living proof of attempting transfiguration from motions of China. The significance of this study was to be able to put stepping-stone to interpretate history of Taekwondo which takes center stage on bare hands martial arts and analyzed the meaning of historical martial arts on Gwonbeop in Joseon Dynasty.

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

Cultivation of Ginseng in Baengnyeongdo, the Northernmost Island of the Yellow Sea in South Korea (서해 최북단 섬 백령도의 인삼 재배 현황)

  • Cho, Dae-Hui
    • Journal of Ginseng Culture
    • /
    • v.4
    • /
    • pp.128-141
    • /
    • 2022
  • Baengnyeongdo Island, which belongs to Ongjin-gun, Incheon, is an island in the northernmost part of the West Sea in South Korea. Baengnyeong Island is the 15th largest island in Korea and covers an area of 51 km2. The Korea Ginseng Corporation (KGC) investigated the possibility of growing ginseng on Baengnyeong Island in 1996. In 1997, thanks to the support of cultivation costs from Ongjin-gun, the first ginseng seedbed was built on Baengnyeong Island. In 1999, the seedlings were transplanted to a permanent field under a contract with KGC. In 2003, the first six-year-old ginseng harvest was performed, and KGC purchased all production according to the contract. Since then, KGC has signed on to grow ginseng until 2012 and purchased six-year-old ginseng until the fall of 2016. Since 2014, the GimpoPaju Ginseng Agricultural Cooperative Association has signed a ginseng production contract. According to a survey of nine 6-year-old ginseng fields (total 5,961 units) on Baengnyeong Island, the top five with good growth had a survival rate of 42.6 to 68%, and the bottom four with poor growth had an extremely low survival rate of 11.1 to 21.3%. The four fields with low survival rates were where hot peppers were planted before ginseng cultivation. It is believed that the excess nitrogen remaining in the soil due to the treatment of compost or manure during pepper cultivation causes ginseng roots to rot. The average incidence of Alternaria blight was 8.6%. Six six-year-old ginseng gardens were low at 1.1 to 4.7%, while the other three were high at 16.7 to 20.9%. It is assumed that the reason for the low survival rate and high incidence of Alternaria blight is a rain-leaking shield. Farmers used rain-leaking shields because the precipitation on Baengnyeong Island was smaller than on land. One field showed 3% of leaves with yellowish brown spots, a symptom of physiological disturbance of the leaf, which is presumed to be due to the excessive presence of iron in the soil. To increase the production of ginseng on Baengnyeong Island, it is necessary to develop a suitable ginseng cultivation method for the island, such as strengthening the field management based on the results of a scientific study of soil, using rain-resistant shading, and installing drip irrigation facilities. I hope that ginseng will become a new driving force for the development of Baengnyeong Island, allowing ginseng products and food to thrive in the beautiful natural environment of the island.

The Effects of Increased Temperature on Yield Properties, Antioxidant Contents, and Pollen Viability of Adzuki Bean (Vigna angularis L.) Responses in Temperature Gradient Greenhouse and Growth Periods (온도구배온실에서 온도상승이 생육시기별 팥의 수량, 항산화 성분, 화분 임성에 미치는 영향)

  • Eun Ji Suh;Ok Jae Won;Jae-Sung Park;Won Young Han;Jin Hee Seo;Sun Tae Kim;Hye Rang Park
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.2
    • /
    • pp.47-58
    • /
    • 2023
  • The quality and yield of crops produced using field cultivation are expected to decrease due to the recent global climate change caused by extreme weather. The plant reproductive stage associated with crop yields is a highly vulnerable period to global warming caused by high temperatures. This study analyzed the adzuki bean's yield properties, antioxidant contents, and pollen viability of adzuki bean (Vigna angularis L.) under high-temperature stress and growth periods in a temperature gradient greenhouse that forms 0 to 4℃ above the outside temperatures. As the main variety of red beans cultivated in Korean farms, the "Arari" red bean was grown in the rain shield greenhouse and the temperature gradient greenhouse from 2021 to 2022 in Milyang, Korea. Compared to 2022, it showed a 0 - 1.0℃ lower temperature during the whole growth period in 2021. However, its average temperatures were 0 - 3.7℃ higher in the vegetative stage and 0.4 - 2.4℃ higher in the anthesis stage in 2021. The lowest yield (6.8 ± 0.7 g) was at the highest temperature (T4: low, 23.6℃; average, 28.5℃; high, 35.8℃) during the anthesis stage in 2021. The temperatures of the mature stage were 1.7 - 3.9℃, which were higher in 2022 than in 2021, although the low temperatures of 2022 were lower than in 2021. The yields of the mature stage in 2022 increased more than in 2021 because of the high temperature of the mature stage. The growth and yield were good at 40.5℃ in the vegetative stage. However, growth was poor when the average temperature was 27.0℃ or higher, and yields decreased during the flowering period. Total polyphenol and flavonoid contents were increased, and the pollen viability was 40.75% in the whole growth period at high temperature (T4: low, 22.9℃; average, 28.8℃; high, 36.9℃). These results showed that the antioxidant levels increased when the antioxidant component was affected at higher temperatures than at normal. In contrast, the pollen viability-related yield decreased as the temperature increased. Our results are the basic data for field growers and the breeding of thermos-tolerance in adzuki beans to prepare for the changeable future climate.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.

Results of Radiation Therapy and Extrafascial Hysterectomy in Bulky Stage IB, IIA-B Carcinoma of the Uterine Cervix (종괴가 큰 병기 IB, IIA-B 자궁경부암에서 방사선치료와 Extrafascial Hysterectomy의 결과)

  • Kim Jin Hee;Lee Ho Jun;Choi Tae Jin;Do Cha Soon;Lee Tae Sung;Kim Ok Bae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • Purpose : To evaluate the efficacy of radiation therapy and extrafascial hysterectomy in bulky stage IB, IIA-B uterine cervix cancers. Methods and Materials : Twenty four patients with bulky stage IB and IIA-B carcinoma of the uterine cervix were treated with extrafascial hysterectomy following radiation therapy due to doubts of residual disease at Department of therapeutic radiology, Keimyung University, Dongsan Hospital, from April 1986 to December 1997 According to FIGO staging system, there were 7 patients with stage IB, 9 patients with IIA and 8 patients with IIB stage whose median age was 45. Pathologic distribution showed 16 patients with squamous cell carcinoma and 8 patients with adenocarcinoma. Seven patients had tumors that are less than 5cm in size and 17 patients had tumors with larger than 5cm. The mean interval between radiation therapy and extrafascial hysterectomy was 57 days. The radiation therapy consisted of external irradition to the whole pelvis (180 cGy/fraction, mean 4100 cGy) and parametrial boost (for a mean total dose of 5000 cGy) with midline shield (4H 10 cm), followed by intracavitary irradiation up to 7500 cGy to point A (maximum 8500 cGy). The maximum follow up duration was 107 months and mean follow up duration was 42 months. Results :Ten out of 24 patients (41.7%) had residual disease found at the time of extrafascial hysterectomies. Five year overall survival rate (5Y OSR) and five year disease free survival rate (5Y DFSR) were 63.6% and 62.5% respectively. Five year overall survival rate for stage IB and IIA was 71.4% and 50% for stage IIB. There was a significant difference in 5Y OSR and 5Y DFSR between patients with and those without residual disease (negative vs positive, 83.3% vs. 40% (P=0.01), 83.3% vs 36% (P=0.01) respectively). There was a notable tendency of better survival with adenocarcinoma than with squamous cell carcinoma (adenocarcinoma vs squamous cell carcinoma, 85.7% vs. 53.3% (P=0.1), 85.7% vs. 50.9% (P=0.1) of 5Y OSR and 5Y DFS respectivey). Total dose to A point did not make a significant difference in survival rate or the existence of residual lesion (< 7500 cGy, ${\geq}$ 7500 cOy). It was also noted that significantly more frequent local failures have occurred in patients with positive residual disease compared with negative residual disease (5/10 vs. 0/14, p=0.003), There was no death related to the treatment. Conclusion : There was no improvement of residual disease and to the overall survival rate in spite of increased total dose to point A. We conclude that there is a possible beneficial effect of radiation therapy followed by extrafaseial hysterectomy in survival for adenocarcinoma of bulky stage IB and IIA-B uterine cervix. We need to confirm this with longer follow up and with large number of patients.

  • PDF

Results of Hyperfractionated Radiation Therapy in Bulky Stage Ib, IIa, and IIb Uterine Cervical Cancer (종괴가 큰 병기 Ib, IIa, IIb 자궁경부암에서 다분할 방사선치료의 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 1997
  • Purpose : To evaluate the efficacy of hyperfractionated radiation therapy in carcinoma of the cervix, especially on huge exophytic and endophytic stage Ib, IIa and IIb Materials and Materials : Fourty one patients with carcinoma of the cervix treated with hyperfractionated radiation therapy at the Department of Therapeutic Radiology, Dongsan Hospital, Keimyung University. School of Medicine from Jul, 1991 to Apr, 1994. According to FIGO s1aging system, therewere stage Ib (3 patients) IIa (6 patients) with exophytic ($\geq$5cm in dinmeter) and huge endophytic mass. and IIb (32 patients) with median age of 55 yeavs old. Radiation therapy consisted of hyperfractionated external irradition to the whole pelvis (120cGy/fraction, 2 fraction/day (minimum interval of 6 hours), 3600-5520cGy) and boost parametrial doses (for a total of 4480-6480cGy) with midline shield $(4\times10cm)$, and combined with intracavitary irradiation (up to 7480-8520cGy in Ib, IIa and 8480-9980cGy in IIb to point A). The maximum and mean follow up durations were 70 and 47 months respectively . Results : Five year local control rate was $78\%$ and the actuarial overall five year survival rate was $66.1\%$ for all patients, $44.4\%$ for stage Ib, IIa and $71.4\%$ for stage IIb. In bulky IIb (above 5cm in tumor size, 11 patients) five year local control rate and five rear survival rate was $88.9\%,\;73\%$ respectively Pelvic lymph node status (negative : $74\%,\;positive:25\%$, p=0.0015) was significant Prognostic factor affecting to five rear survival rate. There was marginally significant survival difference by total dose to A point ($>84Gy\;:\;70\%,\;>84Gy\;:\;42.8\%$, p=0.1). We consider that the difference of total dose to A point by stage (mean Ib,IIa : 79Gy. IIb 89Gy P=0.001) is one of the causes in worse local control and survival of Ib,IIa than IIb The overall recurrence rate was $39\%$ (16/41). The rates of local failure alone. distant failure alone. and combined local and distant failure were $9.7\%,\;19.5\%,\;and\;9.7\%$, respectively. Two Patients developed leukopenia ($\geq$ grade 3) and Three patients develoued grade 3 gastrointestinal complication. Above grade 3 complication was not noted. There was no treatment related death noted. Conclusion : We thought that it may be necessary to increase A point dose to more than 85Gy in hyperfractionated radiotherapy of huge exophytic and endophvtic stage Ib,IIa. We considered that hyperfractionated radiation therapy may be tolerable in huge exophytic and endophytic stage IIb cervical carcinoma with acceptable morbidity and possible survival gain but this was results in small patient group and will be confirmed by long term follow up in many patients.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.