• 제목/요약/키워드: Shell element

검색결과 1,102건 처리시간 0.017초

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

토마토 페이스트 첨가 홍합통조림의 제조 및 저장중의 품질 안전성 (Preparation and Keeping Quality of Canned Sea Mussel using Tomato Paste)

  • 노윤이;공청식;윤호동;이상배;남동배;박태호;권대근;김정균
    • 수산해양교육연구
    • /
    • 제23권3호
    • /
    • pp.410-424
    • /
    • 2011
  • 품질이 보다 우수한 토마토 홍합 통조림을 제조하기 위하여, 최적조미조건을 관능검사를 통하여 설정하였으며, 홍합을 자숙한 후 301-3호관에 충전 밀봉하여 $118^{\circ}C$ 에서 Fo값이 8-12분이 되도록 토마토 홍합통조림을 제조하여 각 살균 조건별 시료에 대하여 내용물의 이화학적 성질의 변화 및 관능적 변화를 조사하였으며, 아울러 Fo 값이 8분인 토마토 홍합을 90일간 저장하연서 저장 중 품질변화에 대하여 살펴보았다. 1. Fo값 8, 10, 12 인 토마토홍합 통조림을 제조하여 각 살균 조건별로 가열처리에 의한 토마토 홍합 통조림의 품질차이를 조사한 결과를 요약하면 다음과 같다. 즉, 살균조건별 pH의 변화는 거의 없었으며, VBN은 열처리 정도에 따라 상당량 증가하였다. 시료 홍합 통조림의 정미성분 중 유리아미노산은 Fo 값이 증가할수록 약간씩 증가하였다. 총아미노산과 유리아미노산의 주요 아미노산은 glutamic acid 및 aspartic acid 이었다. 엑스분 중의 주요 무기질 성분은 Na, K, P 및 Mg이었으며 Fo값이 증가할수록 상당량 감소하였다. 조직감 면에서는 고온에서의 열처리로 인한 조직의 변화보다는 가열 및 가압에 따든 수분의 유출로 인해 조직이 단단해지는 것으로 나타났다. 각 살균 조건별로 관능검사를 실시한 결과 색조, 냄새, 맛 및 조직감 등 시료간의 관능검사 점수가 차이가 나지 않았고, panel member 들이 관능적 차이를 구별하기 힘들다는 의견이 지배적이었다. 따라서 살균원가가 가장 저렴하고 상업적 살균 조건에도 만족되는 Fo 값 8분인 제품을 생산하는 것이 바람직하다고 판단되었다. 2. Fo 값 8분으로 제조한 토마토 홍합통조림의 저장 중 품질변화를 조사한 결과를 요약하면 다음과 같다. 즉, 수분 (78.7~79.9%), 조단백질 (14.9~15.6%), 조지방(2.3~2.6%) 및 조회분(2.1~2.3%) 함량은 저장기간에 따른 변화가 거의 없었다. 또한 휘발성 염기질소 함량도 10.9~11.7mg/100g 으로 큰 차이는 보이지 않았다. 명도(L값 32.3~37.5)의 경우 저장 중 차이는 거의 없었으나, 적색 (a값, 18.3~6.5) 및 황색도(b값, 18.0~17.0)의 경우 저장기간이 길어질수록 점차 감소하였다. 한편, 육 색깔의 갈변도(${\Delta}E$값, 66.6~64.2)는 저장기간에 따른 차이는 거의 없었다. 지질의 산화정도를 알 수 있는 TBA값은 제조 직후 0.099에서 저장 90일에 0.123으로 증가하였다. 저장 중 토마토 홍합 통조림의 아미노 질소의 함량은 미미하나마 증가하였다. 유리아미노산의 총량은 저장 90일이 920.1mg/100g 으로 가장 높았으며, 주요 유리아미노산은 glutamic acid, taurine asparagine glycine 등 이었다. 토마토 홍합의 무기이온성분은 Na 및 K가 가장 많았으며, 다음이 P, Mg 및 Ca의 순 이었다. 관능검사에서 색/ 냄새 및 조직감의 평가에서는 저장기간에 따른 차이가 거의 없었으나, 맛 및 종합평가에서는 90일 저장한 토마토 홍합 통조림이 그 값이 가장 높았다.