• Title/Summary/Keyword: Sheet Function

Search Result 358, Processing Time 0.026 seconds

Optimal Design of Permanent Magnet Thrust Bearings (영구자석형 스러스트 베어링의 최적 설계)

  • Yoo, Seong-Yeol;Kim, Woo-Yeon;Kim, Seung-Jong;Lee, Wook-Ryun;Bae, Yong-Chae;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.353-358
    • /
    • 2011
  • In this paper, we describe a process for optimally designing a ring-type permanent magnet thrust bearing. The bearing consists of two sets of permanent magnet rings. One set is located inside the other set. An axial offset between the two sets creates axial force, which results in a thrust bearing function. In order to realize an optimal design of the bearing where the required load capacity of the bearing is achieved with the least magnet volume, we derived analytical design equations by adopting the equivalent current sheet (ECS) method. We considered the following two types of magnet arrays: axial arrays and Halbach arrays. These two types of arrays are optimized using the analytical design equations. The results of the optimization are verified using three dimensional (3D) finite element analyses (FEA). The results show that the Halbach array can achieve the required load capacity with less amount of permanent magnet than the axial array does. The efficacy of the ECS method is also verified by using 3D FEA. It is found that the accuracy of ECS method is more sensitive to the underlying assumptions for the Halbach array than for the axial array.

Performance of Serial Communication Protocols through Conducting Threads (전도성사를 매체로 한 직렬 통신 프로토콜 성능)

  • Kim, Na-Young;Kim, Hwan;Kim, Juk-Young;Kwon, Young-Mi
    • Journal of Internet Computing and Services
    • /
    • v.12 no.5
    • /
    • pp.21-28
    • /
    • 2011
  • Recently medical and entertainment applications using conducting textile are suggested, but the data of conducting threads are not characterized, classified and verified. Only the data sheet published by manufacturing companies is available. Thus we need to verify the performances of the threading threads in communication. And we need a guideline if the existing communication protocols can be used for the conducting threads communication or the new specific communication protocols have to be developed for the communication. This paper classifies the characteristics of conducting threads made by domestic and overseas companies. Based on the criteria we classified conducting threads into three classes: class A, class B and class C. Further we carried out experiments to verify the adaptability of existing simple serial communication protocols such as RS232. Six different conducting threads are used in experiments and the length of each thread was 0.5m, 1m, 2m and 3m. The data transmission rate and error rate are collected and analyzed. RS485 is very prone to error due to static electricity from human and environment. So it may not be appropriate as long-distance communication protocol up to 12km which is possible in theory. RS232 shows stable and error-less data transmission ability even though every conducting thread didn’t show transmission capability over RS232. USB protocol shows high data rate transmission but the distance cannot be exceeded over 2m. Additionally, USB requires stable power supply. But if the power is supplied through conducting thread, its function is not.

Development of Smartphone Application for Cognitive Behavioral Therapy-Based Case Management in Patients with Schizophrenia (조현병 환자의 인지행동치료 기반 사례관리를 위한 스마트폰 애플리케이션 개발)

  • Kim, Sung-Wan;Lee, Ga-Young;Yu, Hye-Young;Park, Ji-Hyun;Lee, Yong-Sung;Kim, Ju-Wan;Park, Cheol;Lee, Ju-Yeon;Lee, Yo-Han;Kim, Jae-Min;Yoon, Jin-Sang
    • Korean Journal of Schizophrenia Research
    • /
    • v.19 no.1
    • /
    • pp.10-16
    • /
    • 2016
  • Objectives : This article aims to describe the development of smartphone application for the case management of patients with schizophrenia. Methods : Gwangju Bukgu-Community Mental Health Center developed and launched a smartphone application (HYM) for cognitive-behavioral case management and symptom monitoring. The development of the application involved psychiatrists, nurses, social workers, psychologists, and software technicians from a software development company (Goosl Corp.). Results : The HYM application for clients includes six main modules including Thought record, Symptom record, Daily life record, Official notices, Communication, and Scales. The key module is the 'Thought Record' for self-directed cognitive-behavioral treatment (CBT). When the client writes and sends the self-CBT sheet to the case manager, the latter receives a notification and can provide feedback in real time. 'Communication' and 'Official notices' are useful for promoting communication between case managers and clients with schizophrenia. Ratings in 'Symptom record', 'Daily life record', and 'Scales' modules are stored in graphic or table form representing changes in them and shared with case managers. Conclusion : The interactive function of this application is the key characteristics that distinguishes it from other mobile self-treatment tools. This smartphone application may contribute to the development of a youth- and customer-friendly case management system for individuals with early psychosis.

The Carbon Stock Change of Vegetation and Soil in the Forest Due to Forestry Projects (산림 사업에 의한 산림 식생 및 토양 탄소 변화)

  • Heon Mo Jeong;Inyoung Jang;Sanghak Han;Soyeon Cho;Chul-Hyun Choi;Yeon Ji Lee;Sung-Ryong Kang
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.4
    • /
    • pp.330-338
    • /
    • 2023
  • To investigate the impact of forestry projects on the carbon stocks of forests, we estimated the carbon stock change of above-ground and soil before and after forestry projects using forest type maps, forestry project information, and soil information. First, we selected six map sheet with large areas and declining age class based on forest type map information. Then, we collected data such as forest type maps, growth coefficients, soil organic matter content, and soil bulk density of the estimated areas to calculate forest carbon storage. As a result, forest carbon stocks decreased by about 34.1~70.0% after forestry projects at all sites. In addition, compared to reference studies, domestic forest soils store less carbon than the above-ground, so it is judged that domestic forest soils have great potential to store more carbon and strategies to increase carbon storage are needed. It was estimated that the amount of carbon stored before forestry projects is about 1.5 times more than after forestry projects. The study estimated that it takes about 27 years for forests to recover to their pre-thinning carbon stocks following forestry projects. Since it takes a long time for forests to recover to their original carbon stocks once their carbon stocks are reduced by physical damage, it is necessary to plan to preserve them as much as possible, especially for highly conservative forests, so that they can maintain their carbon storage function.

An Analysis of Nursing Behavior and Unit of Treatment Cost of Non- Insurance Patients (종합병원의 비보험환자 처치행위 양상과 수가분석에 관한 연구)

  • 오세영
    • Journal of Korean Academy of Nursing
    • /
    • v.10 no.1
    • /
    • pp.41-55
    • /
    • 1980
  • The medical care insurance system, being put into practice nearly for three years, seem to have brought about some considerable problems as serious for the government as to consider a revision of that system. As one of the most serious problems of present system, the treatment cost of insurance patients is so remarkably low in comparison with than of non-insurance cases that normal operation of hospitals is threatened and care services of low quality are induced. The researcher carried out this survey to analyze and bring to light several aspects of treatment cost of non-insurance patients as a material for a re-assessment of the cost of insurance cases which shows a a considerable difference in amount at the standpoint of hospitals with than of non-insurance cases and further, hoping the significant blind spot of present insurance system(that is, the absence of regulations' for cost assessment by patterns or types of health care treatment) will be mended in near future. The survey was carried out with the treatment invoice sheets of total 902 in-hospital Patients of a general hospital in Seoul during the period of the 2 nd quarter of the year(1979). Among total 902 patients, 694 cases were used for analysis, because those disease or syndromes shared by less than 10% of the patients were put aside before procession. The data were analyzed by kinds or types of diseases, demographic characteristics of patients, hospitalization patterns, types of nursing treatment, etc. The result of analysis was as follows 1. Among all the non-insurance cases, those who received one or more kinds of nursing treatment mounted up to 96. 7 %. The invoice issue frequency per person was 7.2 times, while that frequency per day for a person was 0.8, : the treatment cosr per person was ₩22,650 while its daily average was ₩2,430, due to the average 9.3 in-hospital days per person. 2. As to the nursing treatment types by the demographic characteristics of patients and hospitalization patterns. a. The unit cost female patients was generally more expensive them that of males, and independent nursing service was more given than other types of treatment. As to age, higher age groups received independent nursing service most, while the youngest group received instrumental and integrated nursing services. b. As to room grade, the unit cost of I.C.U. cases was the highest : and the cast of private room patients was higher than that of public room patients. By in-hospital days, the curve of function showed L. type : that is, the longer stay, the lower function. 3. State of treatment types by kinds of disease were ; a. Dependent nursing service showed comparatively high availability in surgical and neurologic disease and independent nursing service was most received by medical, obstetrical and urological patients, while instrumental and integrated services were most available for respiratory disease and obstetrical and neurologic diseases next. b. The invoice issue frequency per day for a patient was highest in obstetrical disease 3.8 times, and the unit cost(per one invoice sheet) was also highest in obstertrical disease(₩10,880) and next in neurologic cases(₩ 4,690 ). 4. As to the pertained departments. a. Cost amount per person was highest in department of Psychiatries daily cost was highest in obstetrical cases : while the invoice issue frequency was highest in obstetrics and next in pediatrics. b. In departments in need of surgical operation, dependent nursing care was highly availabl : while in internal medicine and obstetrics, independent service was higher. Psychiatrics showed the highest the of integrate nursing while pediatrics and obstetrics higher of instrumental services. The variation co-efficien of treatment cost came out to be relatively in high in special surgery, opthalmology and internal medicine. 5. State of treatment cost by types of nursing behavior was. a. The average frequency of invoice issue was 3.5 (times). Among the type four types of treatment, instrumetal service (4.3) and independent nursing behavior(3.9) showed higher frequency than average respectively. But as to unit cost (per invoice). dependent (₩5,200) and integrated (₩5,340) nursing care services were higher than average and considerably higher than the other two types. b. In repect patient distribution. independent nursing behavior(80.3% ) was the highest and depend ent nursing (31.7% ) the lowest. The variation co-efficient of treatment cost appeared highest in dependent nursing be havior as a whole, and among that, doctor's diagnosis showed the highest coefficient value (100.7). In conclusion, the variaty of treatment cost(treatment itself ) by various characteristics and treatment types pro- that treatment various sort of patients and treatment cost of various types of nursing behavior cannot be uniform. Therefore, to attain the equalization of health care service and its cost both for insurant and non-insurant patients, a more specific provision for assessment of cost should be added to the present medical care insurance system and, in addition, the cost of nursing treatment is desired to be inserted into the treatment invoice.

  • PDF

A bilayer diffusion barrier of atomic layer deposited (ALD)-Ru/ALD-TaCN for direct plating of Cu

  • Kim, Soo-Hyun;Yim, Sung-Soo;Lee, Do-Joong;Kim, Ki-Su;Kim, Hyun-Mi;Kim, Ki-Bum;Sohn, Hyun-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.239-240
    • /
    • 2008
  • As semiconductor devices are scaled down for better performance and more functionality, the Cu-based interconnects suffer from the increase of the resistivity of the Cu wires. The resistivity increase, which is attributed to the electron scattering from grain boundaries and interfaces, needs to be addressed in order to further scale down semiconductor devices [1]. The increase in the resistivity of the interconnect can be alleviated by increasing the grain size of electroplating (EP)-Cu or by modifying the Cu surface [1]. Another possible solution is to maximize the portion of the EP-Cu volume in the vias or damascene structures with the conformal diffusion barrier and seed layer by optimizing their deposition processes during Cu interconnect fabrication, which are currently ionized physical vapor deposition (IPVD)-based Ta/TaN bilayer and IPVD-Cu, respectively. The use of in-situ etching, during IPVD of the barrier or the seed layer, has been effective in enlarging the trench volume where the Cu is filled, resulting in improved reliability and performance of the Cu-based interconnect. However, the application of IPVD technology is expected to be limited eventually because of poor sidewall step coverage and the narrow top part of the damascene structures. Recently, Ru has been suggested as a diffusion barrier that is compatible with the direct plating of Cu [2-3]. A single-layer diffusion barrier for the direct plating of Cu is desirable to optimize the resistance of the Cu interconnects because it eliminates the Cu-seed layer. However, previous studies have shown that the Ru by itself is not a suitable diffusion barrier for Cu metallization [4-6]. Thus, the diffusion barrier performance of the Ru film should be improved in order for it to be successfully incorporated as a seed layer/barrier layer for the direct plating of Cu. The improvement of its barrier performance, by modifying the Ru microstructure from columnar to amorphous (by incorporating the N into Ru during PVD), has been previously reported [7]. Another approach for improving the barrier performance of the Ru film is to use Ru as a just seed layer and combine it with superior materials to function as a diffusion barrier against the Cu. A RulTaN bilayer prepared by PVD has recently been suggested as a seed layer/diffusion barrier for Cu. This bilayer was stable between the Cu and Si after annealing at $700^{\circ}C$ for I min [8]. Although these reports dealt with the possible applications of Ru for Cu metallization, cases where the Ru film was prepared by atomic layer deposition (ALD) have not been identified. These are important because of ALD's excellent conformality. In this study, a bilayer diffusion barrier of Ru/TaCN prepared by ALD was investigated. As the addition of the third element into the transition metal nitride disrupts the crystal lattice and leads to the formation of a stable ternary amorphous material, as indicated by Nicolet [9], ALD-TaCN is expected to improve the diffusion barrier performance of the ALD-Ru against Cu. Ru was deposited by a sequential supply of bis(ethylcyclopentadienyl)ruthenium [Ru$(EtCp)_2$] and $NH_3$plasma and TaCN by a sequential supply of $(NEt_2)_3Ta=Nbu^t$ (tert-butylimido-trisdiethylamido-tantalum, TBTDET) and $H_2$ plasma. Sheet resistance measurements, X-ray diffractometry (XRD), and Auger electron spectroscopy (AES) analysis showed that the bilayer diffusion barriers of ALD-Ru (12 nm)/ALD-TaCN (2 nm) and ALD-Ru (4nm)/ALD-TaCN (2 nm) prevented the Cu diffusion up to annealing temperatures of 600 and $550^{\circ}C$ for 30 min, respectively. This is found to be due to the excellent diffusion barrier performance of the ALD-TaCN film against the Cu, due to it having an amorphous structure. A 5-nm-thick ALD-TaCN film was even stable up to annealing at $650^{\circ}C$ between Cu and Si. Transmission electron microscopy (TEM) investigation combined with energy dispersive spectroscopy (EDS) analysis revealed that the ALD-Ru/ALD-TaCN diffusion barrier failed by the Cu diffusion through the bilayer into the Si substrate. This is due to the ALD-TaCN interlayer preventing the interfacial reaction between the Ru and Si.

  • PDF

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.