• Title/Summary/Keyword: Shear characteristic

Search Result 502, Processing Time 0.021 seconds

Strength characteristic transformation of weathered soil caused by freezing-thawing (동결 -융해에 따른 풍화토의 강도특성 변화)

  • 김수삼;박영목;정승용;김용수
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.520-525
    • /
    • 2001
  • It's strongly recommended to check upon the slope stability of soil nearby railroad, since the freezing-thawing repeat in long term may cause decrease of slope stability. The study is, therefore, focused on the strength characteristic transformation of soil, measuring it experimentally, throughout physical and mechanical tests operated by the freezing-thawing repeat tests. The sampling of weathered soil used for the embankment materials along the domestic railway lines are classified by parent-rock, and then collected after it in the first hand. It tells that Uniaxial strength and axial strain were decreased simultaneously as the frequency of freezing-thawing repeat increased and its range was reduced into 25~85 percentage off comparing to uniaxial strength of unfreezing-soils when about 100 times of freezing-thawing repeats occurred. Following the result of direct shear tests, the cohesion of freezing-soil with freezing-thawing repeats shows 11∼60 percentage less than that of unfreezing-soil but the change of internal friction angle of the soil is extremely slight, enough to ignore. As a result. it could be found that strength characteristic transformation has highly correlated with freezing-thawing repeat.

  • PDF

Slope Stability Analysis by Optimization Technique Considering Unsaturated Characteristics of Weathered Granite Soil (화강풍화토 지반의 불포화 특성을 고려한 최적화기법에 의한 사면안정해석 방법)

  • 이승래;이성진;변위용;장범수
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.123-133
    • /
    • 2001
  • Since most of soil slopes are in an unsaturated state, it is necessary to consider the unsaturated characteristics of soil slopes, in order to obtain more reasonable results. Therefore in this study we supplemented a slope stability analysis program to consider them, based on the concept of limit equilibrium. We also applied an optimization technique to search for a failure surface. Besides, we carried out experiments to obtain the unsaturated soil properties required in the analysis with weathered granite soils. We formulated a nonlinear apparent cohesion relationship with the matrix suction to be able to apply the unsaturated shear strength characteristics to the stability analysis. In addition, we intended to obtain more accurate soil water characteristic curves(SWCC) by measuring the change in volume of the specimen in the SWCC tests. As a result, we could appropriately assess the change of the safety factor according to the rainfall intensity and duration, by considering the variation of suction, permeability, and shear strength caused by the infiltration of rainfall into slopes.

  • PDF

An Experimental Study on the Bonding Characteristic of Steel Tubular Joint Connection filled with Fiber Reinforced High Performance Cementeous Grout (섬유보강 고성능시멘트계 그라우트가 적용된 강관 연결부의 부착특성에 대한 실험적 연구)

  • Oh, Hong-Seob;Seo, Gyo;Kim, Sang-Hyeon;Ko, Sang-Jin;Lee, Hyeon-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • This paper deals with the bonding characteristic of grouted joint connections of monopile support structures for offshore wind power facilities. For the integration of pile connection of wind power supporting structure, fiber reinforced high performance cementeous grout was developed and the ultimate compressive strength of it is 125MPa and the direct tensile strength is 7.5 MPa at 7 days. To assess the bond strength of grout filled in pile connection, small scaled direct bond tests under axially loaded was performed and analyzed according the existing guidelines. The fiber volume fraction (0%, 0.5% and 0.9%), aspect ratio of fiber (60 and 80) and the ratio of height to spacing of shear key (0.013 and 0.056) were adopted as the experimental variables. From the test results, the maximum bond strength among the all specimens was 30.8MPa and the bond strength of grouted connection was affected by the ratio of height to spacing of shear key than the fiber volume fraction.

Dispersion Characteristics of Ag Pastes and Properties of Screen-printed Source-drain Electrodes for OTFTs (Ag Pastes의 분산 특성 및 스크린 인쇄된 OTFTs용 전극 물성)

  • Lee, Mi-Young;Nam, Su-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.835-843
    • /
    • 2008
  • We have fabricated the source-drain electrodes for OTFTs by screen printing method and manufactured Ag pastes as conductive paste. To obtain excellent conductivity and screen-printability of Ag pastes, the dispersion characteristics of Ag pastes prepared from two types of acryl resins with different molecular structures and Ag powder treated with caprylic acid, triethanol amine and dodecane thiol as surfactant respectively were investigated. The Ag pastes containing Ag powder treated with dodecane thiol having thiol as anchor group or AA4123 with carboxyl group(COOH) of hydrophilic group as binder resin exhibited excellent dispersity. But, Ag pastes(CA-41, TA-41, DT-41) prepared from AA4123 fabricated the insulating layer since the strong interaction between surface of Ag powder and carboxyl group(COOH) of AA4123 interfered with the formation of conduction path among Ag powders. The viscosity behavior of Ag pastes exhibited shear-thinning flow in the high shear rate range and the pastes with bad dispersion characteristic demonstrated higher shear-thinning index than those with good dispersity due to the weak flocculated network structure. The output curve of OTFT device with a channel length of 107 ${\mu}m$ using screen-printed S-D electrodes from DT-30 showed good saturation behavior and no significant contact resistance. And this device exhibited a saturation mobility of $4.0{\times}10^{-3}$ $cm^2/Vs$, on/off current ratio of about $10^5$ and a threshold voltage of about 0.7 V.

Effect of Anisotropic Ratio for Rayleigh Wave of a Half-Infinite Composite Material (반 무한 복합체의 Rayleigh 표면파에 대한 이방성비의 영향)

  • Baek, Un-Cheol;Hwang, Jae-Seok;Song, Yong-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.3
    • /
    • pp.502-509
    • /
    • 2001
  • In this paper, when stress waves are propagated along the reinforced direction of the composite, the characteristic equation of Rayleigh wave is derived. The relationships between velocities of stress waves and Rayleigh wave are studied for anisotropic ratios(E(sub)11/E(sub)12 or E(sub)22/E(sub)11). The increments of anisotropic ratios is made by using known material properties and being constant of basic properties. When the anisotropic ratios are increased, Rayleigh wave velocities to the shear wave velocities are almost equal to 1 with any anisotropic ratios. Rayleigh wave velocities to the longitudinal wave velocities and Shear wave velocities ratio to the longitudinal wave velocities are almost identical each other, they are between 0.12 and 0.21. When the anisotropic ration is very high, that is, E(sub)11/E(sub)22=46.88, Rayleigh wave velocities and the shear wave velocities are almost constant with Poissons ratio, longitudinal wave velocities are very slowly increased with the increments of Poissons ratios. When E(sub)11(elastic modulus of the reinforced direction)and ν(sub)12 are constant, Rayleigh wave velocities and the shear wave velocities are steeply decreased with the increments of anisotropic ratios and the velocities of longitudinal wave are almost constant with them. When E(sub)22(elastic modulus of the normal direction to the fiber) and ν(sub)12 are constant, Rayeigh wave velocities is slowly increased with the increments of anisotropic ratios, the shear wave velocities are almost constant with them, the longitudinal wave velocities are steeply increased with them.

A parametric shear constitutive law for reinforced concrete deep beams based on multiple linear regression model

  • Hashemi, Seyed Shaker;Sadeghi, Kabir;Javidi, Saeid;Malakooti, Mahmoud
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.285-294
    • /
    • 2019
  • In the present paper, the fiber theory has been employed to model the reinforced concrete (RC) deep beams (DBs) considering the reinforcing steel bar-concrete interaction. To simulate numerically the behavior of materials, the uniaxial materials' constitutive laws have been employed for reinforcements and concrete and the bond stress-slip between the reinforcing steel bars and surrounding concrete are taken into account. Because of the high sensitivity of DBs to shear deformations, the Timoshenko beam theory has been applied. The shear stress-strain (S-SS) relationship has been defined by the modified compression field theory (MCFT) model. By modeling about 300 RC panels and employing a produced numerical database, a study has been carried out to show the sensitivity of the MCFT model. This is performed based on the multiple linear regression (MLR) models. The results of this research also illustrate how different parameters such as characteristic compressive strength of concrete, yield strength of reinforcements and the percentages of reinforcements in different directions get involved in the shear behavior of RC panels without applying complex theories. Based on the results obtained from the analysis of the MCFT S-SS model, a relatively simplified numerical S-SS model has been proposed. Application of the proposed S-SS model in modeling and analyzing the considered samples indicates that there is a good agreement between the simulated and the experimental test results. The comparison between the proposed S-SS model and the MCFT model indicates that in addition to the advantage of better accuracy, the main advantage of the proposed method is simplicity in application.

Experimental investigation of shear connector behaviour in composite beams with metal decking

  • Qureshi, Jawed;Lam, Dennis
    • Steel and Composite Structures
    • /
    • v.35 no.4
    • /
    • pp.475-494
    • /
    • 2020
  • Presented are experimental results from 24 full-scale push test specimens to study the behaviour of composite beams with trapezoidal profiled sheeting laid transverse to the beam axis. The tests use a single-sided horizontal push test setup and are divided into two series. First series contained shear loading only and the second had normal load besides shear load. Four parameters are studied: the effect of wire mesh position and number of its layers, placing a reinforcing bar at the bottom flange of the deck, normal load and its position, and shear stud layout. The results indicate that positioning mesh on top of the deck flange or 30 mm from top of the concrete slab does not affect the stud's strength and ductility. Thus, existing industry practice of locating the mesh at a nominal cover from top of the concrete slab and Eurocode 4 requirement of placing mesh 30 mm below the stud's head are both acceptable. Double mesh layer resulted in 17% increase in stud strength for push tests with single stud per rib. Placing a T16 bar at the bottom of the deck rib did not affect shear stud behaviour. The normal load resulted in 40% and 23% increase in stud strength for single and double studs per rib. Use of studs only in the middle three ribs out of five increased the strength by 23% compared to the layout with studs in first four ribs. Eurocode 4 and Johnson and Yuan equations predicted well the stud strength for single stud/rib tests without normal load, with estimations within 10% of the characteristic experimental load. These equations highly under-estimated the stud capacity, by about 40-50%, for tests with normal load. AISC 360-16 generally over-estimated the stud capacity, except for single stud/rib push tests with normal load. Nellinger equations precisely predicted the stud resistance for push tests with normal load, with ratio of experimental over predicted load as 0.99 and coefficient of variation of about 8%. But, Nellinger method over-estimated the stud capacity by about 20% in push tests with single studs without normal load.

A Study of Characteristic of Friction Angles between Sand and Artificial Rock Interface by Direct Shear Test (직접전단시험에 의한 모래와 인공암석 경계면의 마찰각 특성 연구)

  • Yang, Hong-Suk;Lee, Byok-Kyu;Jang, Seung-Jin;Lee, Su-Gon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.65-73
    • /
    • 2012
  • Soil-rock interface, mainly founded in Granite region of Korea, is known as one of the important factor of the slope failure at the rainfall due to smaller shear strength than soil itself. However, research of the effect on slope stability by soil-rock interfaces is insufficient. Therefore, a series of direct shear tests were performed in order to investigate the effect of soil-rock interface on slope stability. The method of tests is to get sand itself and sand-artificial rock interface shear strength from different grain size of sands and artificial rock samples. The results of tests show that the friction angle of interface depends primarily on particle size and surface roughness. Interface friction angle ratio ${\mu}(={\delta}/{\Phi})$ is in the range of 0.75 ~ 0.96, this results indicate that interface friction angle is smaller than sand itself.

Damage detection of shear buildings using frequency-change-ratio and model updating algorithm

  • Liang, Yabin;Feng, Qian;Li, Heng;Jiang, Jian
    • Smart Structures and Systems
    • /
    • v.23 no.2
    • /
    • pp.107-122
    • /
    • 2019
  • As one of the most important parameters in structural health monitoring, structural frequency has many advantages, such as convenient to be measured, high precision, and insensitive to noise. In addition, frequency-change-ratio based method had been validated to have the ability to identify the damage occurrence and location. However, building a precise enough finite elemental model (FEM) for the test structure is still a huge challenge for this frequency-change-ratio based damage detection technique. In order to overcome this disadvantage and extend the application for frequencies in structural health monitoring area, a novel method was developed in this paper by combining the cross-model cross-mode (CMCM) model updating algorithm with the frequency-change-ratio based method. At first, assuming the physical parameters, including the element mass and stiffness, of the test structure had been known with a certain value, then an initial to-be-updated model with these assumed parameters was constructed according to the typical mass and stiffness distribution characteristic of shear buildings. After that, this to-be-updated model was updated using CMCM algorithm by combining with the measured frequencies of the actual structure when no damage was introduced. Thus, this updated model was regarded as a representation of the FEM model of actual structure, because their modal information were almost the same. Finally, based on this updated model, the frequency-change-ratio based method can be further proceed to realize the damage detection and localization. In order to verify the effectiveness of the developed method, a four-level shear building was numerically simulated and two actual shear structures, including a three-level shear model and an eight-story frame, were experimentally test in laboratory, and all the test results demonstrate that the developed method can identify the structural damage occurrence and location effectively, even only very limited modal frequencies of the test structure were provided.

Analysis of Shear Behavior and Fracture Characteristics of Plywood in Cryogenic Environment (극저온 환경 하 플라이우드의 전단 거동 및 파손 특성 분석)

  • Son, Young-Moo;Kim, Jeong-Dae;Oh, Hoon-Kyu;Kim, Yong-Tai;Park, Seong-Bo;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.394-399
    • /
    • 2019
  • Plywood is a laminated wood material where alternating layers are perpendicular to each other. It is used in a liquefied natural gas (LNG) carrier for an insulation system because it has excellent durability, a light weight, and high stiffness. An LNG cargo containment system (LNG CCS) is subjected to loads from gravity, sloshing impact, hydrostatic pressure, and thermal expansion. Shear forces are applied to an LNG CCS locally by these loads. For these reasons, the materials in an LNG CCS must have good mechanical performance. This study evaluated the shear behavior of plywood. This evaluation was conducted from room temperature ($25^{\circ}C$) to cryogenic temperature ($-163^{\circ}C$), which is the actual operating environment of an LNG storage tank. Based on the plywood used in an LNG storage tank, a shear test was conducted on specimens with thicknesses of 9 mm and 12 mm. Analyses were performed on how the temperature and thickness of the plywood affected the shear strength. Regardless of the thickness, the strength increased as the temperature decreased. The 9 mm thick plywood had greater strength than the 12 mm thick specimen, and this tendency became clearer as the temperature decreased.