• 제목/요약/키워드: Shear Reinforcement

검색결과 1,285건 처리시간 0.035초

전단보강이 없는 철근콘크리트 보의 전단 전달 메카니즘에 관한 실험적 연구 (A Experimental Study on the Shear Transfer Mechanism of Reinforced Concrete Beams without Shear Confinement)

  • 박정현;이근광;윤정배;홍기섭;이원복
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.125-130
    • /
    • 1992
  • If reinforced concrete beam exists crack, ultimate shear transfer strength and shear hardness of section with crack substantially decrease. In this study , five model beams were designed for the objective of clarfying contributions of three shear resistant elements : the compression zone of concrete, dowel action of tension reinforcement, aggregate interlock across cracks, The shear force carried by each resistant element was calculated from the detailed strain data on the contributions to the shear capacity of beams of the shear forces carried by the other three resistant element. The test result follows : 1) Compression zone of concrete (C)-56.2%, 2) Dowel action of tension reinforcement (D)-18.0%, 3)Aggregate Interlock(A)-25.8%.

  • PDF

철근콘크리트 보의 전단마찰모델 (Shear-Friction Truss Model for Reinforced Concrete Beams)

  • 홍성걸;하태훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.873-878
    • /
    • 2001
  • This Paper Presents a new model, called the “shear-friction truss model,” for slender reinforced concrete beams to derive a clear and simple equation for their ultimate shear strength. In this model, a portion of the shear strength is provided by shear reinforcement as in the traditional truss model, and the remainder by the shear-friction mechanism. Friction resistance is derived considering both geometrical configuration of the rough crack surface and material Properties. The inclined angle of diagonal strut in the traditional truss model is modified to satisfy the state of balanced failure, when both stirrups and longitudinal reinforcement yield simultaneously. The vertical component of friction resistance is added to the modified truss model to form the shear-friction truss model. Test results from published literatures are used to find the effective coefficient of concrete strength in resisting shear on inclined crack surfaces.

  • PDF

구조 실험과 SASW를 이용한 플랫 플레이트 기둥-슬래브접합부에서의 구조적 거동에 관한 연구 (Structural Behavior in Slab-Column Connections with Shear Plate Using Structural Experiment and Non-destructive Test, Spectral Analysis of Surface Waves)

  • 주현지;조영상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.48-51
    • /
    • 2004
  • This paper is to study the response of flat plate slab-column connections consisting of various types of shear reinforcement and steel plate subjected to gravity loadings, mainly punching shear forces using the non-destructive testing, spectral analysis of surface waves and structural experiments. The base specimen failed due to punching shear generated from the gravity. The three other types of slab shear reinforcement and steel plate showed effective in resisting punching shear for these types of connections under gravity loading. This study has focused in evaluating the velocity response of a Surface wave during the early age as the poured concrete specimens have been hardened, the possibility of damage detection in the slab-column connection and the relationship between the punching shear forces and the surface wave velocities under the condition that the punching shear forces had gradually increased until the flat plate slab in slab-column connection had been failed.

  • PDF

전단보강비에 따른 FRP 쉬트의 전단보강성능 (Shear Strengthening Effect of RC Beams with FRP Sheets with respect to Shear Reinforcement Ration)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.68-71
    • /
    • 2004
  • In the shear strengthening with FRP sheets, beams are wrapped around the webs and tension face of critical shear span by fiber sheets. The shear strength of RC beam strengthened with FRP sheets must be calculated based on the effective strain that can be developed in the FRP sheets at ultimate stage because the final failure modes of beams are governed by premature debonding of FRP sheet due to the limitation of bonded length by beam depth. An experimental study is carried out to evaluate the shear strengthening effect of AFRP or GFRP sheets with respect to shear reinforcement ratio of rebar. From the test results, it was found that the additional shear strength provided by GFRP or AFRP can be estimated by $p_w{\cdot}f_w$ based on the maximum effective strain of FRP sheet $4,000m{\mu}$ proposed by ACI 440 committee.

  • PDF

철근콘크리트 내진벽의 구조성능 평가 및 개선 (Evaluation and Improvement of Structural Performance of Reinforced Shear Walls Under Load Reversals)

  • 신종학;하기주;안준석;주정준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.683-688
    • /
    • 1999
  • The purpose of this study is to develop and evaluate the structural performance of various shear walls, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crashing due to slippage prevention of boundary region and reduction of diagonal tension rather than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by 1.14 times and 1.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

전단저항키 실험 및 내진성능평가 (Experimental and Analytical Evaluation of Seismic Performance of Shear-Resistance Key)

  • 박종철;강형택;박찬민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.523-528
    • /
    • 2000
  • In multi-span bridges, a shear key is often used to distribute the seismic force to the case, the shear key is sometimes required to be reinforced to withstand the seismic force. To improve the strength of shear key, the strength and failure mode of shear key have to be carefully estimated and the proper reinforcement scheme should be elaborated. The test results show that the strength of shear key is 2.5 times higher than the strength calculated by PCI design handbook. Also the strength of shear key is greatly improved by placing PT bars into shear key. In this study, the analytical method to evaluate the strength of sheat key and the reinforcement scheme are proposed.

  • PDF

Shear Strength of Prestressed Steel Fiber Concrete I-Beams

  • Tadepalli, Padmanabha Rao;Dhonde, Hemant B.;Mo, Y.L.;Hsu, Thomas T.C.
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.267-281
    • /
    • 2015
  • Six full-scale prestressed concrete (PC) I-beams with steel fibers were tested to failure in this work. Beams were cast without any traditional transverse steel reinforcement. The main objective of the study was to determine the effects of two variables-the shear-span-to-depth ratio and steel fiber dosage, on the web-shear and flexural-shear modes of beam failure. The beams were subjected to concentrated vertical loads up to their maximum shear or moment capacity using four hydraulic actuators in load and displacement control mode. During the load tests, vertical deflections and displacements at several critical points on the web in the end zone of the beams were measured. From the load tests, it was observed that the shear capacities of the beams increased significantly due to the addition of steel fibers in concrete. Complete replacement of traditional shear reinforcement with steel fibers also increased the ductility and energy dissipation capacity of the PC I-beams.

철근콘크리트 보와 프리스트레스트 콘크리트 보의 전단설계기준에 대한 고찰 (Evaluation of Shear Design Provisions for Reinforced Concrete Beams and Prestressed Concrete Beams)

  • 김강수;김상식
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.717-726
    • /
    • 2005
  • 본 논문에서는 기존의 전단실험결과를 모아 구축한 방대한 데이터베이스를 이용하여 철근콘크리트 보와 프리스트레스트 콘크리트 보에 대한 ACI와 국내의 전단설계기준을 평가 분석하였다. 또한 두 전단설계기준에 대한 평가결과를 바탕으로 기준의 안전율과 강도감소계수에 대하여도 고찰하였다. 전단설계기준은 철근콘크리트 부재의 전단강도에 대해서 매우 낮은 정확도를 보였으며, 특히 전단철근이 없는 철근콘크리트 보의 전단강도에 대하여 가장 낮은 정확도를 제공하였다. 또한 기준에서 전단강도에 대한 전단철근의 기여도의 제한은 다소 낮은 것으로 분석되었으며, 특히 전단철근이 없고 휨인장철근비가 낮으며$(\rho_w<1.0\%)$ 춤이 높은 (h>700mm) 보에 대하여 매우 위험한 전단강도를 제공하였다. 프리스트레스트 콘크리트 부재에 대해서는 철근콘크리트 부재에 비하여 매우 정확한 전단강도를 제공하였다. 그러나, ACI와 국내의 전단설계기준은 전단강도의 예측정확도가 매우 다른 철근콘크리트 부재와 프리스트레스트 콘크리트 부재에 대해 동일한 강도감소계수를 사용함으로써 이들 부재에 대해 동일한 수준의 설계안 전율을 제공하지 못하였다.

전단스팬비가 작은 철근콘크리트 부재의 전단내력평가에 관한 해석적 연구 (An Analytical Study on the Shear Capacity of Reinforced Concrete Member with Small Shear Span Ratio)

  • 강석화
    • 콘크리트학회지
    • /
    • 제6권5호
    • /
    • pp.193-202
    • /
    • 1994
  • 본 연구에서는 전단스팬비가 작은 철근콘크리트부재를 대상으로, 기존에 주로 실험치에만 의존하여 제안되었던 전단내력식에서 탈피하여 극한해석법중의 하계정리를 이용하여 이론적으로 제안하였다. 본연구에서 제안한 모델에서는 아치기구와 트러스기구를 동시에 고려할 수가 있고 각각의 기구에서 분담하은 힘의 크기를 알 수 있다. 또한, 외부에서 가해진 힘이 어떻게 지검에 전달되고 있는가 시각적으로 이해할 수가 있으며, 전단스팬비(a/b), 전단보강근비, 인장철근비 등의 영향을 정량적으로 고려할 수가 있다. 본 연구에서 유도한 전단내력식을 기존의 실험치와 비교한 결과, 본 연구에서 제안한 식은 실험치와 대체로 일치하며, 다른 연구자에 의해 제안된 전단내력평가식에 손색이 없음을 알았다.

Effect of Glass Fiber-Reinforced Connection on the Horizontal Shear Strength of CLT Walls

  • JUNG, Hongju;SONG, Yojin;HONG, Soonil
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.685-695
    • /
    • 2020
  • The connection performance between cross-laminated timber (CLT) walls and support has the greatest effect on the horizontal shear strength. In this study, the horizontal shear performance of CLT walls with reinforced connection systems was evaluated. The reinforcements of metal bracket connections in the CLT connection system was made by attaching glass fiber-based reinforcement to the connection zone of a CLT core lamina. Three types of glass fiber-based reinforcement were used: glass fiber sheet (GS), glass fiber cloth (GT) and fiber cloth plastic (GTS). The horizontal shear strength of the fabricated wall specimens was compared and evaluated through monotonic and cyclic tests. The test results showed that the resistance performance of the reinforced CLT walls to a horizontal load based on a monotonic test did not improve significantly. The residual and yield strengths under the cyclic loading test were 38 and 18% higher, respectively, while the ductility ratio was 38% higher than that of the unreinforced CLT wall. The glass fiber-based reinforcement of the CLT connection showed the possibility of improving the horizontal shear strength performance under a cyclic load, and presented the research direction for the application of real-scale CLT walls.