• Title/Summary/Keyword: Shear Energy

Search Result 1,851, Processing Time 0.034 seconds

A Preliminary Study of Flume Experiments on the Flow Velocity for Initial Formation of Bedforms on Bimodal Sand-sized Sediments (이정 사질 퇴적물의 층면구조 형성 속도에 대한 수조 실험 예비 연구)

  • Kim, Hyun Woo;Choi, Su Ji;Choi, Ji Soo;Kwon, Yoo Jin;Lee, Sang Cheol;Kwak, Chang Hwan;Kwon, Yi Kyun
    • Journal of the Korean earth science society
    • /
    • v.37 no.4
    • /
    • pp.218-229
    • /
    • 2016
  • The bedform stability diagram indicates the shape and size of bedforms that will occur to a given grain size and flow velocity. The diagram has been constructed from experimental data which have been mostly acquired by flume experiments. Generally, the flume experiments have been performed on well sorted sediments with unimodal grain size distribution, in order to understand relationship between grain size and flow velocity. According to the diagram, a ripple structure initiates to be formed from lower flow regime flat bed, as the flow velocity increases on the surface of fine-sand or medium-sand sediments. This study aims to verify that the experimental result of bedform stability diagram will be reproduced in our flume experimental systems, and also to confirm that the result is consistent not only on well-sorted sand sediments but also on poorly-sorted sand sediments with bimodal grain size distribution. The experimental results in this study show that initiation of 2D or 3D ripple structure on poorly-sorted sand sediments requires higher flow velocity and shear stress than those for initiation of the structure on well-sorted sand sediments. In general, carbonate sediments are characterized by poor sorting due to inactive hydraulic sorting and bimodal grain size distribution with allochems and matrices. The results suggest that the carbonate depositional system possibly need a higher flow velocity for initial formation of 2D or 3D bedform structures. The reason might be the fact that pulling off and lifting of a grain in poorly sorted sediments require more energy due to sorting, friction, stabilization, armour effects, and their complex interaction. This preliminary study warrants additional experiments under various conditions and more accurate analysis on the relationship between formation of bedforms and grain size distribution.

Effects of Feeding Dehulled Soybean Meal on Growth Performance, Carcass Characteristics and Meat Quality Parameters in Berkshire Pigs (탈피대두박 급여가 흑돼지의 생산성, 도체 및 육질 특성에 미치는 영향)

  • Song, Y.M.;Kim, H.Y.;Sin, I.S.;Lee, H.S.;Lee, S.D.;Jung, H.J.;Park, J.C.;Moon, H.K.
    • Journal of Animal Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • A total of 360 Berkshire(hog) weighing 25kg were fed experimental diets containing either dehulled soybean meal(DSBM) or non-dehulled soybean meal(NDSBM) as a major protein source until they reach 80kg. The pigs were then fed the finisher diets either high(3,265 kcal/kg) or low(2,940 kcal/kg) in ME to evaluate the effects of dietary energy level for finisher phase on the growth performances, carcass and meat quality parameter. In growth performance, daily weight gain(kg/day) was higher(P<0.05) in T1 than in other groups. Feed conversion(feed/gain) was lower(P<0.05) in other groups. In carcass parameter, carcass percentage was higher(P<0.05) in T2 than in T1 and T4. Backfat thickness was lower(P<0.05) in T2 than in T1 and T3. The ratio of up B grade in carcass grade tender to be higher in T2 than in other groups. In meat quality, chemical composition was similar between groups. WHC was slighter higher in T1 than in other groups. Shear force was tender to be higher in T1 than in other groups. Hunter L and a in meat color were tender to be higher in T2 than in other groups. Hunter L in backfat color was thender to be higher in T1 than in other groups. The results indicate that growth performance and carcass parameter of Berkshire were improved by the dehulled soybean meal as comparison with non-dehulled soybean meal during growing and finishing periods.

Effects of Dietary Ground, Crumble and Pellet of Physico-chemical Properites on Broiler Meat (가루, 크럼블 및 펠렛사료 급여가 브로일러육의 이화학적특성에 미치는 영향)

  • Cho, H.J.;Kang, S.G.;Cha, Y.H.;Kim, B.K.;Woo, S.C.;Yeoh, Y.S.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.585-592
    • /
    • 2002
  • This study was conducted to investigate the effect of nutrient level (metabolizable energy and crude protein, 2,843kcal/kg and 19.46% at 2 to 3 week, 3,072kcal/kg and 18.38% at 4 to 6 week, 3,109 kcal/kg and 17.26% at 7 to 8week, respectively, and feeding form was ground $\longrightarrow$ crumble $\longrightarrow$ pellet in control, ground $\longrightarrow$ crumble $\longrightarrow$ pellet in treatment 1, crumble $\longrightarrow$ crumble $\longrightarrow$ pellet in treatment 2, pellet $\longrightarrow$ pellet $\longrightarrow$ pellet in treatment 3 for broiler during 8 weeks. Also the effects of supplemented with charcoal(1%) in total mixed treatment feed was investigated. The crude protein, crude fat in broiler meat ranged from 22.22${\sim}$23.40%, and 0.30${\sim}$0.45%, respectively. Especially, treatment 2 was lower than other treatment (P<0.05). The heating loss tend to be increased at control. Shear force and pH tend to be decreased at T3(1.21kg, 5.89). Control and T2 were significantly lighter in color (‘L’) than the T1 and the ‘a’ ranged from 0.19${\sim}$0.85 and T1 was the lowest ‘b’ among other treatment. The panel test, texture, Aroma were not significantly among the an experimental group (P<0.05). Myristic acid and arachidonic acid of T1 was significantly higher than that other treatment and oleic acid, U/S(unsaturated/ saturated) rate T2 was significantly higher than other experimental group(P<0.05). Among amino acid, cystine, glutamic acid, valine, iso-leucine, leucine, lysine, arginine in T1 and T2 was higher than control and T3.

Nondestructive Evaluation and Microfailure Mechanisms of Single Fibers/Brittle Cement Matrix Composites using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 Acoustic Emission을 이용한 단섬유/시멘트 복합재료의 미세파괴 메커니즘과 비파괴적 평가)

  • 박종만;이상일;김진원;윤동진
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.18-31
    • /
    • 2001
  • Interfacial and microfailure properties of the modified steel, carbon and glass fibers/cement composites were investigated using electro-pullout test under tensile and compressive tests with acoustic emission (AE). The hand-sanded steel composite exhibited higher interfacial shear strength (IFSS) than the untreated and even neoalkoxy zirconate (Zr) treated steel fiber composites. This might be due to the enhanced mechanical interlocking, compared to possible hydrogen or covalent bonds. During curing process, the contact resistivity decreased rapidly at the initial stage and then showed a level-off. Comparing to the untreated case, the contact resistivity of either Zr-treated or hand-sanded steel fiber composites increased to the infinity at latter stage. The number of AE signals of hand-sanded steel fiber composite was much more than those of the untreated and Zr-treated cases due to many interlayer failure signals. AE waveforms for pullout and frictional signals of the hand-sanded composite are larger than those of the untreated case. For dual matrix composite (DMC), AE energy and waveform under compressive loading were much higher and larger than those under tensile loading, due to brittle but well-enduring ceramic nature against compressive stress. Vertical multicrack exhibits fur glass fiber composite under tensile test, whereas buckling failure appeared under compressive loading. Electro-micromechanical technique with AE can be used as an efficient nondestructive (NDT) method to evaluate the interfacial and microfailure mechanisms for conductive fibers/brittle and nontransparent cement composites.

  • PDF

Performance, Meat Quality and Blood Composition of Cross Bred Chicks Fed Various Organic Dietary CP and ME (ME와 CP가 다른 유기사료 급여가 토종닭의 생산능력 계육품질 및 혈액성상에 미치는 영향)

  • Park, Jae-Hong;Jeong, Yong-Dae;Yoon, Myung-Ja;Ryu, Kyeong-Seon
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.2
    • /
    • pp.199-214
    • /
    • 2011
  • This study was conducted to investigate the effect of organic dietary metabolizable energy (ME) and crude protein (CP) on productivity, meat quality and blood composition of crossbred chicks (hanhyub 3 ho) for different growring periods. Experiments were factorially designed with ME 3,000, 3,100kcal/kg and CP 21, 22, 23% for starter (0-4wks); ME 3,100, 3,150, 3,200kcal/kg and CP 18, 19, 20% for grower (5-8wks); ME 3,100, 3,150, 3,200kcal/kg and CP 15, 16, 17% for finisher (9-10wks). The total number of chicks and replicate of each treatment for starter, grower, finisher were 720, 4; 702, 6; 468, 4, respectively. The diets was mixed with more 90% organic feed ingredients. The productivity were not influence by dietary ME for starting period. Weight gain and feed intake were significantly increased in CP 23% treatment than CP 21, 22% treatment (P<0.05). FCR was improved as dietary CP increased (P<0.05). Weight gain was tended to be increased by decreaing ME content and increasing CP contents for growing period. Feed intake showed no difference among the ME and CP treatment groups. FCR improved significantly in CP 19, 20% compared with CP 18% (P<0.05). Weight gain was not significantly different between ME and CP treatments for finishing period. Feed intake was lower in ME 3,150, 3,200kcal/kg than the ME 3,100 kcal/kg treatment (P<0.05). FCR was higher in ME 3,100kcal/kg than ME 3,150, 3,200kcal/kg treatment (P<0.05). Interaction on productivity was not exited between ME and CP treatment groups for different feeding periods. There was no difference in the total protein, albumin, glucose and triglyceride amount in blood depending on dietary ME and CP contents. Total cholesterol was greatly decreased in ME 3,100kcal/kg than the ME 3,200kcal/kg (P<0.05), but not different between CP treatments. Cooking loss of breast meat was lower in ME 3,150kcal/kg than the ME 3,200kcal/kg (P<0.05). Moisture, shear force and pH were not statistically different among treatments. Protein solubility was increased by increasing ME and CP in diets. The collagen was tended to increase as dietary ME increased. Redness was remarkably higher in ME 3,150kcal/kg than the ME 3,100kcal/kg (P<0.05). Yellowness of meat fed ME 3,150kcal/kg showed significantly lower than other treatments (P<0.05). Therefore, the optium ME and CP to improve the productivity for each period were 3,000kcal/kg, 23%; 3,100kcal/kg, 19%; 3,150kcal/kg, CP 16%, repectively.

Effects of Deletion of Ca Supplement (limestone) on Growth and Beef Quality in Hanwoo Finishing Steers (한우 비육후기 사료에 칼슘 첨가제(석회석) 제거가 성장 및 육질특성에 미치는 영향)

  • Lee, C.E.;Park, N.K.;Seong, P.N.;Jin, S.H.;Park, B.Y.;Kim, K.I.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.455-462
    • /
    • 2003
  • A study was conducted to determine the effects of feeding a diet containing no Ca supplement (limestone) during the late finishing period on growth, marbling and serum 1,25-dihydroxy vitamin $D_3$ level in Korean native cattle. Twenty-four steers (20${\sim}$24 mo of age) were divided into two groups of 12 each: one group assigned to a control diet (concentrates containing 2.5% limestone) and the other to a diet containing no calcium supplement. They were allowed to have free access to diets (concentrates and orchard grass hay) and water during the entire feeding period (223 d). Serum $Ca^{2+}$, Ca and P concentrations were not influenced by diets, but serum 1,25-dihydroxy vitamin $D_3$ concentrations determined 2 or 6 mo after the beginning of feeding the experimental diets were higher (P<0.01) in steers fed the diet without Ca supplement than in those fed the control diet (78.3 vs 51.7 and 80.3 vs 51.1 pg/mL, respectively). Steers fed the diet without Ca supplement tended to have a higher intake of concentrates, but a lower intake of hay, compared to those fed the control diet. Average daily gain was higher (P<0.05) in steers fed the diet without Ca supplement than in those fed the control diet. Feeding the diet without Ca supplement remarkably (P<0.01) increased the marbling score (5.1 vs 2.2) and the muscle (M. longissimus dorsi) fat content (10.2 vs 6.7%) with a concomitant decrease in moisture content (67.6 vs 70.4%), compared to feeding the control diet. Ribeye area was increased (77.2 vs 82.8 $cm^2$) with the diet without Ca supplement, compared to the control diet (P<0.05). Meat color, pH and water-holding capacity in longissimus muscle were not different between the two groups. The Warner-Brazler Shear (WBS) force of the longissimus muscle was slightly (P=0.08) lower in steers fed the diet without Ca supplement than in steers fed the control diet (2.9 vs 3.2 kg/1.27-cm diameter core). Sensory evaluation showed that feeding the diet without Ca supplement slightly (P<0.05) improved tenderness (4.9 vs 4.5) and flavor (4.9 vs 4.6), compared to feeding the control diet, but juiciness was not affected by diets. Results showed that deletion of Ca supplement from finishing diets is beneficial, increasing growth and marbling partly through an increased energy intake and induced 1,25-dihydroxy vitamin $D_3$ synthesis that may increase intracellular $Ca^{2+}$ concentration and in turn fat synthesis.

Mesothermal Gold-Silver Mineralization at the Bodeok Mine, Boseong Area : A Fluid Inclusion and Stable Isotope Study (전남(全南) 보성지역(寶城地域) 보덕광산(寶德鑛山)의 심부(深部) 중온형(中溫型) 금(金)-은(銀) 광화작용(鑛化作用): 유체포유물(流體包有物) 및 안정동위원소(安定同位元素) 연구(硏究))

  • So, Chil-Sup;Yun, Seong-Taek;Kim, Se-Hyun;Youm, Seung-Jun;Heo, Chul-Ho;Choi, Seon-Gyu
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.433-444
    • /
    • 1993
  • Electrum (32~73 atom. % Ag)-sulfide mineralization of the Bodeok mine in the Boseong area was deposited in two stages of mineralogically simple, massive quartz veins that fill the fractures along fault shear zones in Precambrian gneiss. Radiometric dating indicates that mineralization is Late Jurassic age ($155.9{\pm}2.3$ Ma). Fluid inclusion data show that ore mineralization was formed from $H_2O-CO_2$ fluids with variable $CO_2$ contents ($X_{CO_2}=0.0$ to 0.7) and low salinities (0.0 to 7.4 wt. % eq. NaCl) at temperatures between $200^{\circ}$ and $370^{\circ}C$. Evidence of fluid unmixing ($CO_2$ effervescence) indicates pressures up to 1 kbar. Gold-silver deposition occurred later than base-metal sulfide deposition, at temperatures near $250^{\circ}C$ and was probably a result of cooling and decreasing sulfur activity caused by sulfide precipitation and/or $H_2S$ loss (through fluid unmixing). Calculated sulfur isotope compositions of ore fluids (${\delta}^{34}S_{{\Sigma}S}=1.7$ to 3.3‰) indicate an igneous source of sulfur in hydrothermal fluids. Measured and calculated O and H isotope compositions of ore fluids (${\delta}^{18}O_{water}=4.8$ to 7.2‰, ${\delta}D_{water}=-73$ to -76‰) indicate that mesothermal auriferous fluids at Bodeok were likely mixtures of $H_2O-rich$, isotopically evolved meteoric waters and magmatic $H_2O-CO_2$ fluids.

  • PDF

Rheological Properties of ${\beta}-Glucan$ Isolated from Non-waxy and Waxy Barley (메성 및 찰성보리 ${\beta}-Glucan$의 리올로지 특성)

  • Choi, Hee-Don;Park, Yong-Gon;Jang, Eun-Hee;Seog, Ho-Moon;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.590-597
    • /
    • 2000
  • The rheological properties of ${\beta}-glucans$ isolated from non-waxy and waxy barley were investigated. ${\beta}-Glucan$ solutions showed pseudoplastic properties and their behaviors were explained by applying Power law model in the range of concentrations$(1{\sim}4%)$ and temperatures$(20{\sim}65^{\circ}C)$. The effects of temperature and concentration on the apparent viscosity at $700\;s^{-1}$ shear rate were examined by applying Arrhenius equation and power law equation, and their effect was more pronounced in waxy ${\beta}-glucan$ solutions. The activation energy for flow of ${\beta}-glucan$ solutions decreased with the increase of concentration, and the concentration-dependent constant A increased with the increase of temperature. The intrinsic viscosity of waxy ${\beta}-glucan$ was higher than that of non-waxy ${\beta}-glucan$. The transition from dilute to concentrate region occurred at a critical coil overlap parameter $C^*[{\eta}]=0.02.$ The slopes of non-waxy and waxy ${\beta}-glucan$ at $C[{\eta}] were similar, but the slope of waxy ${\beta}-glucan$ at $C[{\eta}]>C^*[{\eta}]$ was higher than that of non-waxy ${\beta}-glucan$. Dynamic viscoelasticity measurement showed that cross-over happened, and storage modulus was higher than loss modulus at frequency range above cross-over. ${\beta}-Glucan$ solutions formed weak gels after stored for 24 hr.

  • PDF

Fabrication and Filtering Test of Nanoparticle-Stabilized Emulsion to be Suitable for Enhanced Oil Recovery (석유증진회수에 적합한 나노 에멀젼의 제조 및 필터링 시험 분석)

  • Son, Han Am;Lee, Keun Ju;Cho, Jang Woo;Im, Kyung Chul;Kim, Jin Woong;Kim, Hyun Tae
    • Economic and Environmental Geology
    • /
    • v.46 no.1
    • /
    • pp.51-61
    • /
    • 2013
  • Researches on the oil recovery enhancement using the nanotechnology has recently been studied in the United States. The previous researches has focused mainly on the flow characteristics of nanoparticles in porous media, and the stability of the nano-emulsion itself. However, the analysis did not deal with the size effects between a nano-emulsion and the pore size which has an important role when nano-emulsion flows in the porous media. In this research, nano-based emulsion was fabricated which is able to be applied for the enhanced oil recovery techniques and its characteristics was analyzed. In addition, in order to identify the characteristics of nano-emulsions flowing through the porous media, the size effect was analysed by filtering test. According to the results, when the emulsion was fabricated, SCA(Silane Coupling Agent) or PVA(Poly Vinyl Alcohol) are added to improve the stability of emulsion. As the ratio of the decane to water increased, the viscosity of emulsion and the droplet size also increased. For the filtering test at the atmospheric conditions, the droplet did not go through the filter; only the separated water from the emulsion was able to be filtered. This phenomenon occurred because the droplet was not able to overcome the capillary pressure. At the filtering test by suction pressure, most of the emulsion was filtered over the filter size of $60{\mu}m$. However, the ratio of filtration was rapidly degraded at less than $45{\mu}m$ filters. This is caused due to deformation and destruction of the droplet by strong shear stress when passing through the pore. The results from the study on the basic characteristic of nano-emulsion and filtering test will be expected to play as the important role for the fabrication of the stable nano-emulsion or the research on the recovery of residual oil in porous media.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF