• Title/Summary/Keyword: Sharing current control

Search Result 189, Processing Time 0.028 seconds

A new torque sharing function method for torque control of a switched reluctance motor (토크 공유 함수법을 이용한 새로운 방식의 스위치드 리럭턴스 모터의 토크 제어)

  • 최창환;이대옥;박기환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.262-262
    • /
    • 2000
  • This paper presents a new torque sharing function method that extends the definition region of the conventional TSF to both the positive and negative torque production regions. By using this definition, all kinds of the control inputs that consider switching on/off angle control as well as the current profiling can be described. A parametrized representation of the current profiles is proposed by using a series of B-spline functions, which reduces memory requirement and enables additional controllers. Optimal determination of the TSFs are also investigated for various control objectives. Moreover, the comparison study of each objective is presented. Since this method generalizes all of the possible control input, the current and torque profiles obtained from the optimization are the most suitable control input that satisfy the objectives.

  • PDF

The Parallel Operation Control of Static UPSs (정지형 UPS의 병렬운전 제어)

  • Min, Byeong-Gwon;Won, Chung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

Parallel Connected High Frequency AC Link Inverters Based on Full Digital Control

  • Sha, Deshang;Guo, Zhiqiang;Deng, Kai;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • This paper presents a full digital control strategy for parallel connected modular inverter systems. Each modular inverter is a high frequency (HF) AC link inverter which is composed of a HF inverter and a HF transformer followed by a cycloconverter. To achieve equal sharing of the load current and to suppress the circulating currents among the modules, a three-loop control strategy, consisting of a common output voltage regulation (OVR) loop, individual circulating current suppression (CCS) loops and individual inner current tracking (ICT) loops, is proposed. The ICT loops are implemented with predictive current control from which high precision current tracking can be obtained. The effectiveness of the proposed control strategy is verified by simulation and experimental results from parallel connected two full-bridge HF AC link inverter modules.

New Switch-Control Technique for Multiphase Interleaved Converters with Current Sharing and Voltage Regulation

  • Thongbuaban, Ponlawat;Jantharamin, Niphat
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.99-103
    • /
    • 2012
  • This paper presents a new switch-control approach for multiphase interleaved converters. Development of the proposed technique is based on control-signal generation for multi-unit synchronization. Current sharing among the switching cells and voltage regulation are achieved by means of a multi-loop control scheme regardless of changes in input voltage and load. System stability is ensured by single-pole compensation. This proposed technique is straightforward, reliable and inexpensive, and can be applied to any higher number of cells without difficulty.

Current Sharing Method Based on Optimal Phase Shift Control for Interleaved Three-Phase Half Bridge LLC Converter with Floating Y-Connection

  • Shi, Lin;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.934-943
    • /
    • 2019
  • A current balance problem exists in multi-phase LLC converters due to the resonant parameter tolerance. This paper presents a current balancing method for interleaved three-phase half bridge LLC converters. This method regulates the phase shift angle of the driving signals between the three phases based on a converter with a floating Y-connection. The floating midpoint voltage has different influences on each phase current and makes the three-phase current balance performance better than midpoint non-floating systems. Phase shift control between modules can further regulate the midpoint voltage. Then three phase current sharing is realized without adding extra components. The current distributions in a midpoint non-floating system and a midpoint floating system are compared. Then the principle and implementation of the proposed control strategy are analyzed in detail. A 3kW prototype is built to verify the validity and feasibility of the proposed method.

Improved Reactive Power Sharing and Harmonic Voltage Compensation in Islanded Microgrids Using Resistive-Capacitive Virtual Impedance

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1575-1581
    • /
    • 2019
  • Due to the mismatched line impedance among distributed generation units (DGs) and uncontrolled harmonic current, the droop controller has a number of problems such as inaccurate reactive power sharing and voltage distortion at the point of common coupling (PCC). To solve these problems, this paper proposes a resistive-capacitive virtual impedance control method. The proposed control method modifies the DG output impedance at the fundamental and harmonic frequencies to compensate the mismatched line impedance among DGs and to regulate the harmonic current. Finally, reactive power sharing is accurately achieved, and the PCC voltage distortion is compensated. In addition, adaptively controlling the virtual impedance guarantees compensation performance in spite of load changes. The effectiveness of the proposed control method was verified by experimental results.

Load Sharing Control by Following Average Torque Current in Continuous Casting (연속 주조 공정에서 평균 토크전류 추종에 의한 인발력 분배 제어)

  • Chun, Chang-Keun;Kim, Cheul-U
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.74-80
    • /
    • 2004
  • If the withdrawal force of strand driven roll which is controlled with predetermined speed isn't distributed regularly in continuous casting process, mold level is changed cyclically and slab quality is not good. In this paper, both casting speed control and load sharing control algorithm of strand driven roll according to ratio which is set up by operator at same time is proposed. The proposed algorithm is to share the withdrawal force by following torque current of each driven roll as average torque current by changing speed reference of each driven roll motor. The load sharing control with anti-wind up for improvement transient state is adopted and the proposed algorithm is implemented in POSCO pilot caster.

A Master and Slave Control Strategy for Parallel Operation of Three-Phase UPS Systems with Different Ratings (다른 정격용량을 가진 3상 UPS 시스템의 병렬운전을 위한 주종제어 기법)

  • 이우철;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.341-349
    • /
    • 2004
  • A parallel operation of Uninterruptible Power Supply(UPS) systems is used to increase power capacity of the system or to secure higher reliability at critical loads. In the conventional parallel operation, the load-sharing control to maintain the current balance is the most important, since the load-sharing is very sensitive to discord between components of each module, amplitude/phase difference, line impedance, output LC filter, and so on. To solve these problems various control algorithms are researching. However, these methods cannot apply to the different ratings of UPS. In the case, master and slave control algorithm for parallel operation is adequate. However, if the UPS ratings are different, the value of passive filters L, C is different, and it affects the sharing of current. This paper presents general problems of conventional parallel operation systems, and control strategy for parallel operation with different ratings. The validity of the proposed control strategy is investigated through simulation and experiment in the parallel operation system with two 3-phase UPS systems.

A Research on Knowledge Sharing among Air Transportation Professionals (이직종간 지식공유 활성화 방안에 대한 연구 : 항공운항 분야를 중심으로)

  • Kim, Wan-Hyun;Park, Sang-Bum
    • The Journal of Industrial Distribution & Business
    • /
    • v.8 no.6
    • /
    • pp.61-73
    • /
    • 2017
  • Purpose - Aviation control, navigation, and aircraft control in the air transportation area are very specialized. Each part is in progress for safety, efficiency, automation, and further. On the other hand co-work among each part including knowledge sharing has been inattentive for many reasons. The purpose of this research is to show how practicians and professionals in the air transportation area perceive the issue of knowledge sharing and to recall the necessity of knowledge sharing in the area. And we try to find ways to activate the knowledge sharing in the area. Research design, data, methodology - For the research, we inquired into whether practicians and professionals think knowledge sharing can effect safe aviation positively or not and what steps are necessary to activate knowledge sharing in the area. We adopted survey method using questionnaires for current practicians and interview for specialists. The survey and interview results were analyzed using regression analysis and AHP method. The interview for specialists and analyzing the results using AHP was to investigate what are the precedence factors to activate the knowledge sharing. Results - First, practicians perceive that knowledge sharing will affect aviation safe positively. Second objective knowledges such as, tower air traffic control procedure of aviation control area, flight principle and structure of aircraft control area, instrument landing system of navigation area, for knowledge sharing of each area were identified. Also the precedence factors such as, knowledge absorbability of personal factor, personal expectation of result of expectation factor, leadership of management of Structure factor, method of knowledge spread of application factor for knowledge sharing were found. Conclusions - Knowledge sharing for practicians and professionals in the aviation area is very important especially from the perspective of safety. However, for various many reasons including the environment of each special area that focusing on their own area, knowledge sharing has not been emphasized. We found that practicians in the area feel that knowledge sharing is necessary and helpful. For it, each practician's active participation is the most important and many ways such as chatting room to share knowledge are to be developed. And the organization culture should be changed to encourage knowledge sharing.

Parallel operation of VISC system for 3[kw] solar cell (3[kw]급 태양전지 가상구현시스템의 병렬운전)

  • Lee S.Y.;Jeong B.H.;Oh B.W.;Lee B.I.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.957-960
    • /
    • 2003
  • Many solar cell way need to be connected by series or parallel to extract the high power Especially, during parallel operation to reduce circulation current the individual converter has to share and control the load current. Generally, Current Sharing(CS) can be implemented using droop and active current sharing method. In this paper, one 3[KW] PWM converter was replaced as one 3[KW] solar cell array(3 parallels, each parallel has twenty single modules), two 3[KW] solar cell way Is Paralleled to generate 6[KW] power. Also each converter used voltage-current controller and Automatic MSCPM(Master-Slave Current-programming Method) for current sharing(AS).

  • PDF