• Title/Summary/Keyword: Shape Engineering

Search Result 12,820, Processing Time 0.044 seconds

The Geometric Characteristics of Landslides and Joint Characteristics in Gangneung Area (강릉지역 산사태의 기하학적 특성과 절리특성에 관한 연구)

  • Cho, Yong-Chan;Chang, Tae-Woo
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.437-453
    • /
    • 2006
  • More than 3,000 landslides were occurred by torrential rains in Gangneung area due to the typhoon Rusa in 2002. In order to analyze the landslide origin and its geometric characteristics, 1,365 landslide data were collected from the field survey of Sacheon, Jumunjin, and Yeongok areas in which the intensive landslides took place. The average landslide size in the study area was composed of 10m width, 30m length, and $21^{\circ}{\sim}35^{\circ}$ slope angle, and the plane view of landslides A-type (i.e. wide shape of lower part) that contains approximately 50.5% of the landslides commonly occurred. In particular the area of Sacheon heavily damaged by mountain fires had more occurrence of landslides than other areas. The landslides of uniform tendency of slope direction were examined resulted from the contribution of topographic characteristics due to the weathering and wind direction during heavy rainfalls. In order to analyze the direction of joint, 249 orientation data were collected from the study area. The window method was employed to determine the characteristics of joint density in 51 locations of the study area. The results showed that many landslides occurred in the areas of joint density with the range of $0.05{\sim}0.1$.

Characteristics and Implications of Lava Tubes from Geophysical Exploration in Jeju Island (지구물리 탐사에 의해 발견된 제주도 용암동굴의 특징과 의미)

  • Jeon, Yongmun;Ki, Jin Seok;Koh, Su Yeon;Kim, Lyoun;Ryu, Choon Kil
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.473-484
    • /
    • 2015
  • Geophysical exploration using electric resistivity, ground penetrating radar (GPR), and impedance high-frequency (ZHF) surveys was conducted in Gujwa-eup, Jeju City, Jeju Island, an island in the Korea Strait, to confirm the existence of new caves near known caves. The exploration revealed a number of anomaly zones, presumed to be caves; 27 sites at suitable locations and depth ranges were selected for drilling and further surveys. However, contrary to predictions, most of the anomaly zones were clinker layers or paleosols intercalated with lavas. Only five boreholes intersected caves. The clinker layers and paleosols were possibly detected as anomalies owing to their different physical properties from the other rocks. Two of the five cave-finding boreholes penetrated Yongcheon Cave; a new cave was found at the other. The two boreholes that penetrated Yongcheon Cave were drilled in areas where the cave has not been previously reported, and thus helped correct an error in the cave distribution map. The cave newly discovered in this boring exploration is 180 m long, and it is connected to the upstream part of Dangcheomul Cave (110 m). The cave contains well-developed lava helictites, lava levees, and ropy structures; carbonate speleothems such as soda straws, stalagmites, columns, and curtain shawls are also well preserved. Notably, the unique shape of the carbonate speleothems is attributed to their growth in relation to the cavern water that flowed into the cave along plant roots.

Characteristics of Submarine's Turbulent Wake using Analytical Solution of B(ξ) for the given λ (임의 λ에 대한 근사해 B(ξ)를 이용한 잠수함 난류항적 특성 연구)

  • Lee, Yong-Chol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1604-1610
    • /
    • 2017
  • Using analytical solution of $B({\xi})$, I could find out the characteristics of Submarine's turbulent wake for the given various ${\lambda}$, which were unknown facts before. As the results, $B({\xi}){\approx}{\frac{B({\xi})_{max}}{2}}$ and ${{\int}_{0}^{{\approx}0.6}}B({\xi})d{\xi}{\approx}0.85{{\int}_{0}^{1}}B({\xi})d{\xi}$ in the vicinity ${\xi}{\approx}0.6$, there was some dependencies on the given ${\lambda}$ though. The values of ${\lambda}$, in the range of $4{\leq}{\lambda}{\leq}8$, are more suitable to describe submarine's turbulent wake realistically, due to the bases on the quasi equilibrium state of turbulent wake. ${\lambda}$ mainly affects on the radius and detection range of the submarine's turbulent wake on the surface, however, the speed of submarine mainly affect on the duration of the wake rather than shape. If $7{\leq}{\lambda}{\leq}8$, it can be expected that the turbulent wake can be seen on the surface in the West sea, however, snorkeling(or snorkeled) submarine's wake can be found easily in the East sea.

Buffer Intensity of Ammonia and MPA in Water-Steam Cycle of PWRs (가압경수로 원전 물-증기 순환영역에서 암모니아와 MPA의 완충세기)

  • Rhee, In-H.;Ahn, Hyun-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2708-2712
    • /
    • 2010
  • Amines, ammonia or 3-methoxypropylamine (MPA), are used to maintain the optimized pH for the prevention of corrosion in the secondary side of Pressurized Water Reactors (PWRs). They are differently dissociated as a function of temperature which is not same in each location of the water-steam cycle. pH at the operation temperature depends on temperature of fluid and equilibrium constants of water and amines. Thus, every amine provides the different pH in the entire secondary side so that pH is not only the sufficient parameter in corrosion control. The secondary parameter, i.e., buffer intensity, is the ability to maintain a stable pH when $H^+$ are added or removed due to the ingress of impurities or the reaction of corrosion. The buffer intensity is necessary to provide the selection criteria for the best pH control agent for secondary side and the basic understanding of the reason why the flow-accelerated corrosion(FAC) rate may demonstrate the bell-shape curve over temperature. The buffer intensities of ammonia and MPA were reviewed over the entire operation temperature of PWRs. The sufficient buffer intensity is provided for the inhibition of corrosion by ammonia in low temperature $(25{\sim}100^{\circ}C)$ and by DMA in high temperature $(150{\sim}250^{\circ}C)$. In terms of buffer intensity, i) the best pH control agent is an amine with $pK_a(T)$ range of pH(T)- $1{\leq}pK_a(T){\leq}pH(T)$ + 0.5 and ii) the amine solution should have sufficient buffer intensity, ${\beta}$ to inhibit corrosion, and iii) FAC rate may be maximum at the temperature, where ${\beta}_B/{\beta}$ ratio is lowest.

A Prefetching Scheme for Location-Aware Mobile Information Services (위치인식 이동정보서비스를 위한 프리패칭 방법론)

  • Kim, Moon-Ja;Cha, Woo-Suk;Cho, In-Jun;Cho, Gi-Hwan
    • The KIPS Transactions:PartC
    • /
    • v.8C no.6
    • /
    • pp.831-838
    • /
    • 2001
  • Mobile information service aims to provide some degree of effective information for real life activities of mobile users. Due to the user mobility and actual realism, it becomes very important technical issue to support an adaptive information service methodology to current situations of the terminal and/or user. This paper deals with a prefetching scheme for location-aware, out of the various context-aware which can be considered in mobile information service. It makes use of the velocity-based mobility model to shape the terminal and/or user's mobility behavior. Based on the moving speed and direction, the prefetching zone is proposed to define the number of prefetched information, so as to limit effectively the prefetched information whilst to preserve the location-aware adaptability. Using a simulator, the proposed scheme has been evaluated in the effectiveness point of view. The idea in this paper is expected to be able to extended to the other mobile service contexts, such as service time, I/O types of mobile terminals, network bandwidth.

  • PDF

Thermotropic Liquid Crystalline Behavior of [4-{4'-(Nitrophenylazo)phenoxycarbonyl}]alkanoated Celluloses ([4-{4'-(니트로페닐아조)펜옥시카보닐}]알카노화 셀룰로오스들의 열방성 액정 거동)

  • Jeong, Seung-Yong;Ma, Yung-Dae
    • Polymer(Korea)
    • /
    • v.33 no.1
    • /
    • pp.58-66
    • /
    • 2009
  • The thermotropic liquid crystalline behavior of the homologous series of cellulose tri[4-{4'-(nitrophenylazo) phenoxycarbonyl}] alkanoates (NACEn, n=2$\sim$8, 10, the number of methylene units in the spacer) have been investigated. All of the homologoues formed monotropic nematic phases. The isotropic-nematic transition temperature ($T_{iN}$) decreased when n is increased up to 7, but it became almost constant when n is more than 7. The plot of transition entropy at $T_{iN}$ against n had a sharp negative inflection at n=7. The sharp change at n=7 may be attributed to the difference in arrangement of the side groups. The melting temperature ($T_m$) and associated entropy change at $T_m$, in contrast with $T_{iN}$ and associated entropy change at $T_{iN}$, exhibited a distinct odd-even effect, suggesting that the average shape of the side chains in the crystalline phase is different from that in the nematic phase. The thermal stability and degree of order of the nematic phase observed for NACEn were significantly different from those reported for the homologous series of side-chain and combined type liquid crystal polymers bearing azobenzene or biphenyl units in the side chains. The results were discussed in terms of the differences in the chemical structure, the flexibility of the main chain, the mode of chemical linkage of the side group with the main chain, and the number of the mesogenic units per repeating unit.

Fabrication of Electroconductive $Si_3N_4$-TiN Ceramic Composites by In-Situ Reaction Sintering (In-Situ 반응소결에 의한 전도성 $Si_3N_4$-TiN 복합세라믹스 제조)

  • Lee, Byeong-Taek;Yun, Yeo-Ju;Park, Dong-Su;Kim, Hae-Du
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.577-582
    • /
    • 1999
  • In order to make the electroconductive $Si_3N_4$-TiN composities, the Si-Ti(N) compacts were nitrided at $1450^{\circ}C$ for 20hours, and then they were post-sintered by a gas-pressure-sintering technique at 1TEX>$1950^{\circ}C$ for 3.5 hours. As starting powders, commercial si powder of about $10\mu\textrm{m}$, two types of Ti powders of 100 and 325 mesh, and fine-sized TiN of $2.5\mu\textrm{m}$ powders were used. In the $Si_3N_4$-TiN sintered bodies used Ti powders, the relative density and fracture strength and electrical conductivity are low due to the existence of large amounts of coarse pores. However, in the $Si_3N_4$-TiN composite used TiN powder, the fracture toughness, fracture strength and electrical resistivity were $5.0MPa{\cdot}m^{1/2}$, 624MPa and $1400{\omega}cm$, respectively. The dispersion of TiN particles in the composite inhibited the growth of $Si_3N_4$ in the shape of rod and made strong strain field contrasts at the $Si_3N_4$-TiNinterfaces. It was recognized that microstructural control is required to improve the electrical conductivity and mechanical properties of $Si_3N_4$-TiN composites by dispersing TiN particles homogeneously.

  • PDF

A Study on Optimization for Location and type of Dam Considering the Characteristic of Large Fault (대규모 단층특성을 고려한 최적 댐위치 및 형식 선정)

  • Kim, Han-Jung;Lyu, Young-Gwon;Kim, Young-Geun;Lim, Hee-Dae
    • Tunnel and Underground Space
    • /
    • v.22 no.4
    • /
    • pp.227-242
    • /
    • 2012
  • Youngju multipurpose dam is planned to minimizing the damage by flood and obtaining the water for industrial use in Nakdong river region. Faults in rock mass have strong influences on the behaviors of dam structure. Thus, it is very important to analyse for the characteristics of fault rocks in dam design. However, due to the limitation of geotechnical investigation in design stages, engineers have to carry out the additional geological survey including directional boring to find the distribution of faults and the engineering properties of faults for stability of dam. Especially, the selection of location of dam and type of dam considering fault zone must be analyzed through various experimental and numerical analysis. In this study, various geological survey and field tests were carried out to analyse the characteristics of the large fault zone through the complex dam is designed in foundation region. Also, the distribution of structural geology, the shape of faults and the mechanical properties of fault rock were studied for the reasonable design of the location and type of dam for long-term stability of the complex dam.

Application of a Fiber Fabry-Pérot Interferometer Sensor for Receiving SH-EMAT Signals (SH-EMAT의 신호 수신을 위한 광섬유 패브리-페롯 간섭계 센서의 적용)

  • Lee, Jin-Hyuk;Kim, Dae-Hyun;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.165-170
    • /
    • 2014
  • Shear horizontal (SH) waves propagate as a type of plate wave in a thin sheet. The dispersion characteristics of SH waves can be used for signal analysis. Therefore, SH-waves are useful for monitoring the structural health of a thin-sheet-structure. An electromagnetic acoustic transducer (EMAT), which is a non-contact ultrasonic transducer, can generate SH-waves easily by varying the shape and array of magnets and coils. Therefore, an EMAT can be applied to an automated ultrasonic testing system for structural health monitoring. When used as a sensor, however, the EMAT has a weakness in that electromagnetic interference (EMI) noise can occur easily in the automated system because of motors and electric devices. Alternatively, a fiber optic sensor works well in the same environment with EMI noise because it uses a light signal instead of an electric signal. In this paper, a fiber Fabry-P$\acute{e}$rot interferometer (FFPI) was proposed as a sensor to receive the SH-waves generated by an EMAT. A simple test was performed to verify the performance of the FFPI sensor. It is thus shown that the FFPI can receive SH-wave signals clearly.

An Experimental Study on the Thermal Property of Concrete under the Load Ratio Condition in Fire (화재시 하중재하에 따른 콘크리트의 열적특성에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Jung, Jae-Young;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.66-74
    • /
    • 2009
  • When a fire occurs, the concrete structure's strength decreases by the increasing temperature under the fire in certain condition of constant load. And, the ratio of the axial force is changed by such decreased strength so that the structure is deformed. In this research, considering such case, we have conducted an actual fire test for the concrete lining with constant loading condition and various fire conditions. The specimen adopts the shape condition for small practical specimen defined by the EFNARC and we used 24MPa, 40MPa and 50MPa to analyze the thermal properties by the strength. The ratio of loading is imposed by a certain loading condition based on 20% and 40% of the sectional stress in concrete and MHC Fire is selected to realize the thermal impact of the concrete by rapid increasing temperature. As the result of the experiment, in the same ratio of loading, the 50MPa specimen shows more cracks and spalling as time goes on. The area damaged by the fire, according to the functional criteria of the concrete lining under the fire in ITA, does not satisfy with the standard in lack of 50mm depth from the heating surface at total 200mm lining.