• Title/Summary/Keyword: Shading Coefficient

Search Result 26, Processing Time 0.027 seconds

Implementation and the Energy Efficiency of the Kinetic Shading System (가동형 차양 시스템의 구성과 에너지 효율)

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.67-73
    • /
    • 2014
  • This study aims at examining kinetic efficient shading systems and their implementation methods. These days, the importance of the shading devices are getting more significant due to the energy problem. Cordially, suitable shade designs are required as an important element for the exterior envelope of the building. This study employs the optimal shading design as an efficient shading method with the kinetic system that can be converted actively by the altitude of the sun. The proposed kinetic shading system works not only as a lightshelf in case the altitude of the sun is high but also as a vertical louver when the sun is getting lower in order to block the direct sunlight. This study has analyzed the thermal performance and shading coefficient of the kinetic shading system in comparison to existing fixed shading devices using the Ecotect. The results, in sum, conclude that the suggested kinetic shading system could decrease direct sunlights 26.2% more than the existing shading methods.

A study on analysis of energy consumption of Detached house by U-value and SCs of windows and Building Orientation (창의 종류 및 차폐계수 변화와 건물 향에 따른 단독주택의 에너지요구량 분석)

  • Jeong, Su-Hui;Park, Hyo-Sun;Lee, Byung-Yun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • Annual energy consumption in detached houses are affected mainly by thermal performance of envelope. In particular the performance of glasses are critical due to global wanning and climatic change. Therefore, this research analyzes annual consumption of cooling and heating energy with various combination of U-value, shading coefficient and building orientation. The simulation results shows that shading coefficient of glazing contributes to the changes of proportion of heating and cooling energy demand and the optimized shading coefficient for minimizing energy consumption varies with buildings orientation.

Coefficient of Variability of Agronomic Characters in Panax ginseng C.A. Meyer (인삼 주요형질의 변이계수)

  • 안상득;최광태
    • Journal of Ginseng Research
    • /
    • v.9 no.1
    • /
    • pp.9-14
    • /
    • 1985
  • The aerial parts, stem diameter, stem length, Petiole length, leaf length and leaf width were investigated to estimate coefficient of variability in ginseng at 2 to 4 years grown under the conventional and improved shadings. C.V values of characters such as stem length, petiole length, leaf length and leaf width were decreased with increasing the plant age, while that of steam diameter was increased. C.V. values of aerial part characters were higher in conventional shading than in improved shading, and the variance of c.v. was not significant when above 20 plants were investigated.

  • PDF

A Study on the Determination of Optimal Circuit Constants of Shading Coil (Shading Coil의 최적 회로정수 결정에 관한 연구)

  • 김시화
    • Journal of the Korean Institute of Navigation
    • /
    • v.9 no.1
    • /
    • pp.95-109
    • /
    • 1985
  • It has been generally known that the chattering of an AC electromagnetic contactor due to the fluctuation of attracting force is the primary cause of its abrasion and noise. To reduce this chattering effect, an AC electromagnetic contactor is mostly fitted with a shading coil which works the role to make difference in phases of two distinct components of attracting force. The theoretical interpretation of an AC electromagnetic contactor with shading coil and the equation of its attracting force per unit wattage consumed have already been proposed, however, few explications so far have been made on the determination of optimal circuit constants of shading coil. In this paper, the auther constructs a circuit model of an AC electromagnetic contactor with shading coil which is based on the theoretical interpretation of shading coil examined to be valid by experiments under some assumptions, and defines the equation of attracting force without chattering per unit wattage consumed as a performance function for determining the optimal circuit constants of shading coil. And then, the optimal circuit constants maximizing the performance function are determined by means of computer simulation founded on the above circuit model and the characteristics of those circuit constants are examined with special attention to the coupling coefficient.

  • PDF

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201 (NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가)

  • Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

A Experimental Study on Structure Modeling of Ginseng Fields Facility (인삼재배시설의 구조모델링을 위한 실험연구)

  • Oh, Hynn-Kyo;Yoon, Seong-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.181-186
    • /
    • 2005
  • The ginseng field structure collapses due to snow and wind. In order to study the structural modeling of ginseng field facility wind velocity test with shading material and strength test with used and unused timber were performed. The result of wind velocity test, we knew the characteristic of shading member of ginseng facility is followed linear regression, accurately. So, we made the assigned wind-value according to wind velocity. The result of strength test, the strength value of used-timber is smaller than the unused-timber and the coefficient of variance is larger than the unused-timber.

  • PDF

Main Factors affecting on Photosynthesis under shading condition of Codonopsis lanceolata Trautv. (차광조건에서 더덕의 광합성속도에 미치는 주요 요인)

  • Lee, Chung-Yeol
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.5
    • /
    • pp.409-414
    • /
    • 2002
  • This study was carried out in order to investigate the main traits related to photosynthesis by multiple regression analysis. The photosynthetic rate showed more significant increase in shaded leaves of plant than in non-shaded leaves of plant after shading treatment for 44 days. Negative correlation was found between net photosynthetic rate and SLA(specific leaf area). However, the values obtained from the linear equation were different and were highly significance. From the above results, net photosynthetic rate of shading treatment is higher than that of control in the same SLA. We also found that there were correlation between stomatal conductance and SPAD as well as net photosynthetic rate and stomatal conductance. By the multiple regression analysis, SPAD value, SLA, stomatal conductance and leaf water potential showed a higher correlation coefficient of $r=0.848^{**}$. From the results, out of 4 factors(SPAD value, SLA, stomatal conductance, leaf water potential) stomatal conductance was main factor in the view points of partial regressing.

Germanition, Shade Toarance and Community Characteristics on $\emph{Erigeron annuus}$ L.in Cheju (濟州 地域에서 개망초의 發芽 習性 및 耐陰性과 群落特性)

  • Lee, Ho-Joon;Kim, Tae-Sung;Byun, Doo-Weon
    • The Korean Journal of Ecology
    • /
    • v.15 no.2
    • /
    • pp.103-115
    • /
    • 1992
  • This dissertation, which has been prepared in the region of cheju(33o31'N, 126o32'E) from may,1987 to appril, 1989, is to elucidate the dominant characteristics of early stages in secondary succession, by examining the life history of erigeron annuus for the seeding depth of a seed was dependent upon the degree of shading. That is, on the area of ocm,the more tense the shading was, the more germination percentage was increased, while, in the case of 1.5cm, it was somewhat increased, when shading bwcame ess and less tense. The rosette of e. annuus, through its relative light intensity was decreased by shading, up to 5% of natural light, showed some strong shade tolerance, which had no difficulty in matter production. The species diversity of mixed-species community was the highest in the middle of April, the lowest in the last of may. The dominance index was the highest in the late may, the lowest in the middle of April. Toward the end of may, the occupation rate of dominance species was the highest. There was a neutral relationship between intraspecific and interspecific, owing to the differentiation of its niche, temporally and spatially. Productive structure of the community revealed a narrow leaf type which was concentratively distributed in the mid part of community height. The relative light intensity of community ground surface was 6.1%, the leaf inclination 60o,the extinction coefficient(k) 0.4, biomass of community 1,045.6 g.d.w./m2,T/Rratio 9.3, C/Frate 7.0 and sumgermanition, shade toarance and community characteristics on erigeron annuus l.in chejumed leaf area index 3.88. through the various life cycles o e.annuus, we can say that it decreases mortality of seeding caused by some stress and disturbance, for germination lasts for a long time at any opportunity available, and it promotes population growth. The strong shade tolerance of a rosette and the variableness of a life from differentiate the niche between intraspecific and interspecific within the community, and avoid the direct competition between them, thus poromoting community growth.

  • PDF