• Title/Summary/Keyword: ShadeScan$^{TM}$ System

Search Result 4, Processing Time 0.024 seconds

SHADE ANALYSIS OF ARTIFICIAL TEETH USING SHADE $SCAN^{TM}$ SYSTEM (ShadeScan$^{TM}$ System을 이용한 인공치의 색조분석)

  • Sung, Chai-Ryun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.443-457
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze and estimate whether each company may produce the color of artificial teeth as it stands, in the standard of vita classical shade guide using ShadeScan$^{TM}$ System. Material and methods: we chose the products of 6 companies -EFUCERA, IVOCLAR, ENDURA, TRUBYTE, DURADENT, and DURACROSS- estimated the shade value of each fixed point(cervical, body, and incisal area) of artificial tooth, and verified the equality among the samples from the same company. Results: First, the variation appeared significant at cervical and incisal area. It means that there were significant differences between cervical and incisal area although the most similar artificial teeth to the patients’natural teeth were provided. Second, the results in the body area showed that the variation between artificial and natural teeth was finite(p<0.05) in that area. Conclusion: it shows that the reproduction of colors of artificial teeth might be successful regarding the body is the most important part for a determination of the color of artificial teeth. However, more complements are necessary for the better reproduction of the color of artificial teeth between cervical and incisal area.

COMPARISON OF SHADE CHANGES ACCORDING TO DRY/WET CONDITION OF TEETH USING INTRA-ORAL COLORIMETER

  • Lee, Dong-Hwan;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.314-321
    • /
    • 2005
  • Objectives. The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. Materials and methods. Twenty volunteer subjects have no restorations and fillings in the maxillary central incisors were involved in this clinical study. The color of tooth was measured by two different instruments that were a Shade $Scan^{TM}$ System and a VITA $Easyshade^{(R)}$, Five times consecutive measurements were done for each subject with both instruments. Groups of measurement are an initial wet condition as control, dry in 5 minutes, 15 seconds after re-wetting with saliva, re-wetting after 5minutes and re-wetting after 30 minutes. Using ShadeScan $System^{TM}$, tooth image was captured and converted to the mapping image of Vitapan 3D master. Three main shades were chosen from each subject and calculated the area in Global Lab Image software. Data were analyzed using paired T-Test and Wilcoxon Signed Ranked Test. Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between measurements were analyzed with one sample T-test. Results. Using ShadeScan $System^{TM}$, there were significant differences between control group and dry(P=.023), dry and re-wetting 15 seconds, 5 minutes, 30 minutes as well(P=.021, P=.017, P=.030) in comparison of primary shade. However, comparing three main shades, there was no significant difference between control and dry(P=.105). Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between control and dry, dry and re-wetting 30 minutes were statistically different(P=.002, P=.022). Conclusion. Primary shade could be changed in dry and wetting procedure in time, however there was no significant shade changes in overall.

STUDY ON THE COLORS OF PRIMARY INCISORS USING DIGITAL SHADE ANALYSING SYSTEM (Digital Shade Analysing System을 이용한 상악 유절치의 색조에 대한 연구)

  • Oh, Min-Hyung;Lee, Kwang-Hee;Ra, Ji-Young;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.429-437
    • /
    • 2006
  • The purpose of this study was to evaluate the shade of primary incisors. One hundred and nineteen children 394 maxillary anterior primary incisors were assessed. Digital shade analysing system ($ShadeScan^{TM}$, Cynovad, Canada) was used for measuring the shades This system enabled to improve the accuracy and objectivity The images of the teeth were taken with $ShadeScan^{TM}$ and shade maps of the teeth were obtained with $ShadeScan^{TM}$ software. The shades of three regions (cervical third middle third, incisal third) of the teeth were evaluated. The results were as follows : 1. In cervical third of primary incisors, D2 and D3 were the major shades and D2 was the most frequent shade. 2. In middle third of primary incisors, C1, D2, and B1 were the major shades and C1 was the most frequent shade. 3. In incisal third of primary incisors, A2 was the most frequent shade and D2 shade followed.

  • PDF

SHADE ANALYSIS OF ANTERIOR TEETH USING DIGITAL SHADE ANALYSIS SYSTEM (Digital Shade Analysis System을 이용한 전치부의 색조 특성에 관한 연구)

  • Kim Hee-Eun;Cho In-Ho;Lim Ju-Hwan;Lim Hun-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.565-581
    • /
    • 2003
  • Statement of problem : A scientific examination and understanding of overall aspects of the natural dentition is the first step involved in making a satisfactory selection in the shade of an aesthetic prosthesis. Proper natural shade selection of the prosthetic restoration that is in harmony with the remaining dentition is as important aesthetically, as harmony of form and function in the anterior dentition. Clinically, the most commonly applied method of shade selection has been visual, but because of the subjective nature inherent to this method, shade selection results are variable and can be influenced by such factors as the technician, the type of shade guide used, and the type and intensity of the lighting. Purpose : The purpose of this study was to develop a more objective and scientific approach to examining and understanding the shade of teeth, which has in turn lead to the development of a number of shade analysis devices that present a more objective method of shade analysis. Material and Method : In this study, the shades of healthy anterior teeth were examined and analyzed using the recently developed digital shade analysis of the $ShadeScan^{TM}$ System. The study examined 80 individuals in their twenties, 40 males and 40 females, presenting 6 healthy, unrestored maxillary anterior teeth. Tooth brushing and oral prophylaxis were performed prior to evaluation. The ShadeScan handpiece was used to acquire images of the 6 maxillary anterior teeth. These images were analyzed using the Vita/Classical mode of the $ShadeScan^{TM}$ Software, and shade maps of each tooth were acquired and divided into cervical, middle, and incisal thirds. The shade distribution of each third, left and right symmetry, and gender differences were investigated and analyzed. Results : The results of the study are as follows : 1. An overwhelming majority of the examined teeth were found to possess shades belong to Group A, with the greatest variations occurring at the middle and cervical thirds of the maxillary central and lateral incisors, in both male and female subjects. 2. Canines of both male and female subjects showed left and right symmetry with uniform shade distribution of A4 and C4, while the lateral and central incisors showed left-right symmetry of the incisal 1/3 with a uniform shade distribution of A2 and A3 shades 3. No significant differences in shade distribution were seen between genders in maxillary canines, whereas maxillary central and lateral incisors showed differences at the middle and cervical thirds between male and female subjects The results of this study show that with the exception of maxillary canines, maxillary anterior teeth display a diverse shade distribution as well as gender differences. Conclusion : Clinically, when making a shade selection using the existing shade guide, one must consider the fact that even a single tooth consists of a variety of shades. The results of this study show that when selecting a shade from a number of groups is difficult, shades from A group are the most consistent with the natural shade or maxillary anterior teeth.