• 제목/요약/키워드: Sewer

검색결과 715건 처리시간 0.025초

무강우시 합류식 하수관거의 오염부하 특성 (Characteristics of Pollution Loads from the Combined Sewer during Dry Season)

  • 원철희;최용훈;박운지;신민환;최중대
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.137-144
    • /
    • 2011
  • We have examined the pollutant load of combined sewer in dry days. Two monitoring sites (C-1, C-2) were equipped with an flowmeter. Monitoring was conducted from September 2004 to April 2006 for 20 months during dry days. Flowrate and concentration of pollutants are lowest from 3 to 6 o'clock, and it is high at 9, 12 and 21 o'clock. Most of organic matters exist in the dissolved state. The results show that pollution loads in C-2 area were 4.5-7.2 times higher than in C-1. Pollutant loads were high on Saturdays. Pollutant loads (kg/ha/day) of C-2 were 1.1-3.1 times higher those of C-1. However there was no significant difference in winter. Analysis of correlation coefficient of water quality parameter indicates that besides of flowrate all items in C-1 site have tight relationship respectively (p<0.01). In C-2 site, correlation coefficient of TP-SS, TP-TN, TP-flowrate, BOD-flowrate, BOD-SS and TN-TP are statistically significant (p<0.01).

CSOs를 고려한 도시유역의 수량 및 수질 분석을 위한 PCSWMM 모형의 적용 (Application of PCSWMM for the Analysis of Water Quantity and Quality Considering CSOs)

  • 홍원표;정은성;이준석;김경태;이길성
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.26-36
    • /
    • 2009
  • Combined sewer system (CSS) has been built in the most urban areas across the nation. During dry weather conditions, CSS works fine. But during heavy rain storms, combined sewage frequently overflows into the stream. This study simulated the hydrologic cycle and pollutant loads (BOD, SS, TN and TP) in the Mokgamcheon watershed considering combined sewer overflows (CSOs). PC storm water management model (PCSWMM) was used for continuous simulation and CSOs are considered using the flow divider. Sensitivity analysis, calibration and verification for water quantity and quality are carried out. To verify CSOs, field measurements of CSOs are compared with simulated results. As a result, 41.3% of precipitation flows into the stream directly and 1.1% of water supply flows into stream as CSOs. 6.5% of BOD total loads, 12.0% of SS, 13.6% of TP, and 29.2% of TN are from CSOs. This result will be effective to the integrated watershed management for sustainability.

정화조의 효율적인 운영을 위한 실험적 고찰 (An Experimental Investigation for Efficient Operation of Septic Tank)

  • 이장훈;이경수;고수훈;송민희;이수현;이용훈;강선홍
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.123-129
    • /
    • 2012
  • A septic tank is a purification treatment system where night soil and other waste matter is converted into harmless material by the activities of bacteria. Effluent from the septic tank flows into the sewer pipe, and then this effluent affects the quality of water environment and makes foul smell. In this study, through the proper maintenance of septic tank it was tried to minimize the impact of sewer pipe on water quality and fouling smell. BOD removal rate from the septic tank's effluent which exceeded legal cleaning period was investigated for the proper maintenance. BOD Removal rate of the twelve septic tank's effluent is -62.5% to 43.9%. According to the result of BOD removal rate, septic tank cleaning should be done at least once a year. And the pathogenic coliform bacillus in the twelve septic tank's effluent is average 768,000 (MPN/$100m{\ell}$). The chlorine disinfection is needed to remove the pathogenic coliform bacillus in septic tank effluent.

강우시 합류식 하수관거의 유출특성 분석 (Analysis of Storm Water Run-off Characteristics during Wet Weather)

  • 최성현;최승철;박은영;임재명
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.95-101
    • /
    • 2002
  • Much of domestic city is served by combined sewer system rather than separate sanitary or storm sewers. During wet weather, when the volume of sanitary sewage and storm water entering the combined sewers exceeds the system capacity, the system is designed to overflow at several designated CSOs. The objective of this research is to have grasp of characteristics of combined sewer runoff and to evaluate efficiently the intercepted volume of CSOs. During the wet weather in first rainfall, SS load at each site H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, SS load at each site in second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. EMCs at each site were 702mg/L, 816mg/L, 861mg/L in first rainfall and 99.9mg/L, 161.9mg/L, 103.6mg/L in second rainfall, respectively. First flush coefficients b at each site were 0.237, 0.166, and 0.151.

  • PDF

바이모달 트램 모의운행지역에서의 강우에 대한 노선침수 예측 (Prediction of Lane Flooding on a Model Site for Rainfall Safety of Rubber-tired Tram)

  • 박영곤;윤희택;임경재;김종건;박윤식;김태희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1209-1212
    • /
    • 2007
  • Urban flooding with surcharges in sewer system was investigated because of unexpected torrential storm events these days, causing significant amounts of human and economic damages. Although there are limitations in forecasting and preventing natural disasters, integrated urban flooding management system using the SWMM(Storm Water Management Model) engine and Web technology will be an effective tool in securing safety in operating rubber-tired transportation system. In this study, the study area, located in Chuncheon, Kangwon province, was selected to evaluate the applicability of the SWMM model in forecasting urban flooding due to surcharges in sewer system The catchment are 21.10 ha in size and the average slope is 2% in lower flat areas. Information of subcatchment, conjunctions, and conduits was used as the SWMM interface to model surface runoff generation, water distribution through the sewer system and amount of water overflow. Through this study, the applicability of the SWMM for urban flooding forecasting was investigated and probability distribution of storm events module was developed to facilitate urban flooding prediction with forecasted rainfall amounts. In addition, this result can be used to the establishment of disaster management system for rainfall safety of rubber-tired tram in the future.

  • PDF

영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구 (Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin)

  • 진영훈;박성천
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

강우 및 지역특성별 초기우수월류에 의한 오염부하 기여도 평가 (The Estimation of Pollution Loads in First-flush Overflows with Various Rainfall and Regional Characteristics)

  • 김홍태;신동석;김용석
    • 한국물환경학회지
    • /
    • 제30권6호
    • /
    • pp.622-631
    • /
    • 2014
  • The purpose of this research was to find a proper disposal rainfall extent to improve water quality. SWMM was applied to select catchment area and tested first flush load and rainfall extent. BOD 40mg/L was selected to dispose the first flush and sewer overflow with the same as the criteria of Sewerage Act. Design rainfall, BOD load ratio of first flush sewer overflow, and the ratio of disposal flow were analyzed under various rainfall distribution. BOD load and design rainfall to treat overflow in situation of first flush extent with 4.3~17.4% were 56~87% and 3.8~6.8 mm/day, respectively. In urban area, first flush loads were not correspond to land activities, but tend to increase with increasing rainfall amount and drainage area. The more the distribution of rainfall is similar to Huff-frontal or central distribution of rainfall, the more increase the first flush loads.

도시 하천에서의 어류 폐사 원인 분석 II - 자동수질측정장치 및 수질모델의 사용 (Causes of Fish Kill in the Urban Stream and Prevention Methods II - Application of Automatic Water Quality Monitoring Systen and Water Quality Modeling)

  • 이은형;서동일;황현동;윤진혁;최재훈
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.585-594
    • /
    • 2006
  • This study focused on the causes of fish kills and its prevention methods in Yudeung Stream, Daejeon, Korea. Intense field data, continuous water quality monitoring system and water quality modeling were applied to analyze the causes. Pollutant can be delivered to urban streams by surface runoff and combined sewer overflows in rainfall events. However, water quality analysis and water quality modeling results indicate that the abrupt fish kills in the Yudeung stream seems to be caused by combined effect of DO depletion, increase in turbidity and other toxic material. Excessive fish population in the study area may harm the aesthetic value of the stream and also has greater potential for massive fish kills. It is suggested to implement methods to reduce delivery of pollutants to the stream not only to prevent fish kills but also to keep balance of ecosystem including human uses. Frequent clean up of the urban surface and CSO, installation of detention basin will be helpful. In the long run, it seems combined sewer system has be replaced with separate sewer system for more effective pollutant removal in the urban area.

하수관망의 나무뿌리 침입 리스크 평가 (Risk Evaluation of Tree Root Intrusion into Sewer Network)

  • 한상종;신현준;황환국
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.693-702
    • /
    • 2015
  • The objective of this study is to investigate and evaluate that a roadside tree root intrudes sewer network systems. Two approaches were performed to assess the characteristics of tree root intrusion. First, the characteristics of tree roots that had invaded sewers were directly observed by means of closed-circuit television inspection robot. Second, the intrusion proportions of tree root into rain gutters in the sampling area were investigated. As tree species of low intrusion proportions, the results indicated that Ginkgo biloba Linn. and Acer buergerianum Miq. were 1.7% and 4.3%. On the other hand, tree species of high intrusion proportions were Metasequoia glyptostroboides Hu et Cheng, Ulmus davidiana var. japonica Nakai and Zelkova serrata Makino as 22.2%, 20.4%, and 17.6% respectively. In particular, sewers and gutters around Zelkova species should be the focus of maintenance work because of the high proportion of these trees on roadsides.

천공장치를 이용한 배수설비 연결관 시공 기술에 관한 연구 (A Study for Drainage Pipe Construction Method using a Boring Machine)

  • 장재구;강선홍;김동은;정태호
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.869-875
    • /
    • 2011
  • Ministry of Environment has been promoting BTL business of the sewer rehabilitation which continues from 2005 up to now. Sewer rehabilitation is classified into three parts : wastewater pipe rehabilitation, rainwater pipe rehabilitation and drainage equipment rehabilitation. Drainage equipment rehabilitation is that drainage pipe connects wastewater pipe directly without water-purifier. In the drainage equipment construction, it is inevitable to have the damage of ground structures(wall, gate and U drain, etc) when an open excavation method is used. Therefore it is necessary to develop non-excavation method to connect drainage pipe and wastewater pipe like jacking method to avoid the damage of ground structure. This paper has conducted an analysis of the non-excavation method using a boring machine attached to backhoe, which is issued the verification certificate of environmental technology according to the Development of and Support for Environmental Technology Act, article.7. The index set in this analysis was sectionalized to the condition of construction, the grade of drainage pipe, the size of excavated hole, the amount of waste cement concrete and asphalt concrete and the benefit effect compared to open excavation method.