• Title/Summary/Keyword: Sewage treatment water

Search Result 716, Processing Time 0.026 seconds

Characteristic Distributions of Nutrients and Water Quality Parameters in the Vicinity of Mokpo Harbor after Freshwater Inputs (담수 유입에 따른 목포항 주변해역의 영양염 및 수질인자 분포 특성)

  • Kim, Yeong-Tae;Choi, Yoon-Seok;Cho, Yoon-Sik;Choi, Yong Hyeon;Jeon, Seungryul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.617-636
    • /
    • 2015
  • The Mokpo coastal waters receive discharges from three artificial lakes(Youngsan, Youngam, Geumho) and other terrigenous freshwater inflows(streams, sewage treatment effluent, fresh groundwater), which exhibit very high concentrations of nutrients and/or organic matters. To understand spatial distributions of nutrients(DIN, DIP, DSi) and other water quality parameters(Chl-a, water temperature, salinity, DO, COD, SS), field surveys were conducted at 10 stations in the Mokpo harbor and adjacent estuaries on May, July, September, and November 2008 within 10 days following discharge events from artificial lakes. In this study, the freshwater flow rate influxed by the operation of sea dike sluice had significant influence on water qualities of the Mokpo coastal waters, although nutrient concentrations in other freshwater sources such as streams, sewage treatment effluent, and fresh groundwater were much higher. As a result of statistical analysis, DIN, COD, and Chl-a had a negative correlation with salinity. Therefore it was shown that discharge extents, time, and nutrients from the Youngsan lake were major impact factors dominating the spatial characteristics of nutrients and other water quality parameters in the Mokpo harbor and adjacent waters. However, despite non-discharge from the Youngsan Lake on September of this investigated period, it was observed that the nutrient addition was taking place in the lower layer of the estuary suggesting nutrient supply through different pathways. This result has emphasized the need to implement the combined assessment about the cumulative impacts on the Youngsan Estuary environment and ecosystem due to freshwater inputs derived from the artificial lakes as well as other terrigenous inflows, or benthic releases.

Target candidate fish species selection method based on ecological survey for hazardous chemical substance analysis (유해화학물질 분석을 위한 생태조사 기반의 타깃 후보어종 선정법)

  • Ji Yoon Kim;Sang-Hyeon Jin;Min Jae Cho;Hyeji Choi;Kwang-Guk An
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.2
    • /
    • pp.109-125
    • /
    • 2023
  • This study was conducted to select target fish species as baseline research for accumulation analysis of major hazardous chemicals entering the aquatic ecosystem in Korea and to analyze the impact on fish community. The test bed was selected from a sewage treatment plant, which could directly confirm the impact of the inflow of harmful chemicals, and the Geum River estuary where harmful chemicals introduced into the water system were concentrated. A multivariable metric model was developed to select target candidate fish species for hazardous chemical analysis. Details consisted of seven metrics: (1) commercially useful metric, (2) top-carnivorous species metric, (3) pollution fish indicator metric, (4) tolerance fish metric, (5) common abundant metric, (6) sampling availability (collectability) metric, and (7) widely distributed fish metric. Based on seven metric models for candidate fish species, eight species were selected as target candidates. The co-occurring dominant fish with target candidates was tolerant (50%), indicating that the highest abundance of tolerant species could be used as a water pollution indicator. A multi-metric fish-based model analysis for aquatic ecosystem health evaluation showed that the ecosystem health was diagnosed as "bad conditions". Physicochemical water quality variables also influenced fish feeding and tolerance guild in the testbed. Eight water quality parameters appeared high at the T1 site, indicating a large impact of discharging water from the sewage treatment plant. T2 site showed massive algal bloom, with chlorophyll concentration about 15 times higher compared to the reference site.

Nitrogen Removal Characteristic of Excreta Wastewater Using SBR and MBR Processes (SBR 및 MBR 공정을 이용한 분뇨폐수에서의 질소제거 특성)

  • Jung, Jin-Hee;Yoon, Young-Nae;Lee, Seul-Kee;Han, Young-Rip;Lee, Seung-Chul;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1485-1491
    • /
    • 2015
  • There are two treatment processes that are currently applied to ships are the biological treatment process using the activated sludge and the electrochemical treatment. However, neither of them are able to remove both nitrogen and phosphorus due to their limited ability to remove organic matters, which are main causes of the red tide. This study was conducted to identify the characteristics of nitrogen removal factors from manure wastewater by replacing the final settling tank in SBR (Sequencing Batch Reactor) process and applying immersion type hollow fiber membrane. SBR process is known to have an advantage of the least land requirement in special environment such as in ship and the immersion type hollow fiber membrane is more stable in water quality change. As the result, the average in the cases of DO (Dissolved Oxygen) is 2.9(0. 6~3.9) mg/L which was determined to be the denitrifying microorganism activity in anaerobic conditions. The average in the cases of ORP (Oxidation Reduction Potential) is 98.4~237.3 mV which was determined to be the termination of nitrification since the inflection point was formed on the ORP curve due to decrease in the stirring treatment after the aeration, same as in the cases of DO. Little or no variation in the pH was determined to have positive effect on the nitrification. T-N (Total Nitrigen) removal efficiencies of the finally treated water were 71.4%, 72.3% and 66.5% in relatively average figures, thus was not a distinct prominence. In being applied in ships in the future, the operating conditions and structure improvements are deemed necessary since the MEPC (Marine Environment Protection Committee). 227(64) ship sewage nitrogen is less than the standard of 20 Qi/Qe mg/L or the removal rate of 70%.

Effect of Methanol on the Behavior of Urea-N Applied to the Soil Surface under Submerged Condition (담수조건에서 토양의 표면에 시용된 요소태 질소의 행동에 미치는 Methanol의 영향)

  • Lee, Sang-Mo;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.2
    • /
    • pp.99-107
    • /
    • 1997
  • The effect of easily decomposable organic carbon (methanol) application on the behavior of nitrogen derived from surface-applied urea in submerged soil was investigated. Two rates of urea (150 & $300kg-N\;ha^{-1}$) and three levels of methanol (2, 4, 8 ml) were applied to 10 g soil samples. The samples were incubated for 30 days under submerged conditions. The flood water and the soil were sampled for analysis of urea-N, $NH_4-N$ and $NO_3-N$ every 10 days. Urea-N in flood water and in soil at the rate of $150kg-N\;ha^{-1}$ and that in flood water at the rate of $300kg-N\;ha^{-1}$ were not detected but the urea-N concentration in soil at the rate of $300kg-N\;ha^{-1}$ with 8 ml methanol treatment was 4.7 on the 10th day from incubation. $NH_4-N$ concentrations in flood water and in soil increased with increasing urea application rates whereas they decreased with increasing methanol treatment. $NO_3-N$ concentration in flood water and in soil were similar regardless of the urea and methanol application rates. The total amount of $NH_4-N$ in flood water and in soil decreased with increasing methanol treatment, 0 ml & 2 ml, whereas the total amounts of $NO_3-N$ in both flood water and soil increased slightly at higher rates of methanol treatment, 4 ml & 8 ml. The total amount of $NH_4-N$ in both flood water and soil increased up to 20 days of incubation whereas that of $NO_3-N$ in flood water and in soil decreased over incubation time.

  • PDF

Occurrence of UV Filters in Nakdong River Basin : Mainstreams, Tributaries and STP Effluents (낙동강 수계에서의 자외선 차단제류 검출 특성 : 본류, 지류 및 하수처리장 방류수)

  • Seo, Chang-Dong;Son, Hee-Jong;Choi, Jin-Taek;Yoo, Pyung-Jong;Jang, Seong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.472-479
    • /
    • 2015
  • This study was investigated occurrence and distribution patterns of UV filters in Nakdong River basin (mainstream, tributaries and sewage treatment plant (STP) effluents). 5 (EHS, BP-3, 4-MBC, BZC and EHMC) out of 7 UV filters were detected in 5 out of 20 sampling sites (mainstream and tributaries), 7 UV filters were not detected in mainstream samples, and the EHS, BP-3, 4-MBC, BZC and EHMC concentration levels in tributary samples were ND~60.8 ng/L, ND~72.1 ng/L, ND~57.2 ng/L, ND~60.1 ng/L and ND~85.2 ng/L, respectively. 5 (EHS, BP-3, 4-MBC, BZC and EHMC) out of 7 UV filters were detected in effluents of 11 STPs around the Nakdong River basin. The EHS, BP-3, 4-MBC, BZC and EHMC concentration levels in 11 STP effluents were ND~89.3 ng/L, ND~90.8 ng/L, ND~88.1 ng/L, ND~118.5 ng/L and ND~104.4 ng/L, respectively. According to the sampling season, distribution patterns and detected concentrations of 5 UV filters were similar in June and September 2014, but change ranges of distribution patterns and detected concentrations of 5 UV filters were highly variable in April and November 2014.

Analysis study on substances subject to management using long-term water quality monitoring data in tributaries of the Nakdong River basin (낙동강유역 지류에서의 장기 수질모니터링 자료를 이용한 관리 대상물질 분석 연구)

  • Byungseok Kal;Jaebeom Park;Seongmin Kim;Sangmin Shin;Soonja Jang;Minjae Jeon;Donghyun Lee
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.326-334
    • /
    • 2023
  • The purpose of this study is to use long-term water quality monitoring data from tributaries of the Nakdong River system to identify problematic substances in tributaries by examining the rate of exceedance and increase in water quality targets. In the Nakdong River system, monitoring is conducted once a month for 38 tributaries that require intensive management, and this data was used to analyze trends in exceeding and increasing target water quality at each point. The analysis items are eight items that can be evaluated based on river water quality standards: DO, BOD, COD, TOC, SS, total phosphorus, fecal coliform, and total coliform. As a result of the analysis, the target water quality exceedance rate was more than 50%, and the items with an increasing trend were TOC, fecal coliform and total E. coli counts, and the items with an exceedance rate of less than 50% but an increasing trend were SS. TOC is believed to be caused by an increase in non-degradable substances, and the continued increase in Total Coliform will require management of Total ColiformTotal Coliform in effluent water from sewage treatment facilities in the future.

A Study on Removal Efficiency of T-N in Bench-scale for Shipboard Sewage Treatment Plant (Bench-scale 선박용 고도수처리장치에서의 T-N 제거효율 연구)

  • Choi, Young-Ik;Shin, Dae-Yeol;Lee, Seung-Chul;Jung, Jin-Hee;Yoon, Young-Nae
    • Journal of Environmental Science International
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • In this study, the International Maritime Organization (IMO)'s guideline MEPC. 277 (64) was developed and evaluated for the removal efficiency of T-N in a SBR and MBR combined process. This combined process of resized equipment based on large capacity water treatment device for a protection of marine aquatic life. In this experiment, T-N concentration of influent and effluent was measured through with the artificial wastewater. The SBR reactor operation time was varied according to the C : N : P ratios so that different conditions for mixing and aeration period in mins (90 : 60, 80 : 40, 70 : 50) and two C: N: P ratios (10 : 5 : 3, 10 : 3 : 1) were used. During experiment in the reactor's aeration and anoxic tank DO concentrations were 3 mg/L and 0.2 mg/L respectively. Furthermore, in the reactor MLSS concentration was 2000 mg/L and flowrate was 2 L/hr. Experiment results showed that C : N : P, 10 : 3 : 1 ratio with 90 mins mixing and 60 mins aeration maximized removal efficiency at 97.3% T-N as compared to other conditions. The application of the SBR and MBR combined process showed efficient results.

Analyzing the Efficiency of LID Technique for Urban Non-point Source Management - Focused on City of Ulsan in Korea - (저영향개발기법 적용을 통한 비점오염원 저감 및 비용효율 분석에 관한 실증적 연구 - 울산광역시를 대상으로 -)

  • Lim, Yong-Kyun;Jung, Ju-Chul;Shin, Hyun-Suk;Ha, Gyoung-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.2
    • /
    • pp.1-14
    • /
    • 2014
  • The purpose of this study is to identify the efficiency of LID technologies for controlling non-point source pollution from urban areas. The recent technical responses to managing water resource and urban areas according to the influence of climate change is an important national policy, along with green growth. Through various reference studies reasonable ways to consider a wholistic plan on urban-eco-friendly river management, the Low Impact Development (LID) as the adequate river management method is being undertaken in foreign countries to technically apply to urban plans. However, the LID is at the initial stage in Korea, with no specific studies implemented. Thus, this study explored whether LID technologies can be efficient measures to control non-point source pollution on the cost side. Ulsan's Namgu and Bukgu have been chosen as case studies that illustrate the efficiency of the LID technologies. On investigation, if LID technologies are designed properly, the efficiency of them is expected to higher than that of sewage treatment plant.

A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane (암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구)

  • Kang, Heeseok;Lee, Euijong;Kim, Hyungsoo;Jang, Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

Factors Affecting Microbial Respiration (MR) by Rapid Oxygen Uptake Rate (OUR) Monitoring (급속 OUR 모니터링을 이용한 Microbial Respiration (MR) 영향인자 평가)

  • Park, Se-Yong;Mo, Kyung;Kim, Youn-Kwon;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.630-635
    • /
    • 2011
  • As this study was estimation of factors of rapid OUR (Oxygen Uptake Rate) monitoring method. Experiment for estimating factors of optimal microorganism activity was carried out in this study. In addition to comparison and estimation of SCOD variation by OUR variation using real wastewaters. In consequence OUR value was highest when F/M ratio, pH and temperature were 0.03~0.05, 6.0~8.5 and $20{\sim}30^{\circ}C$ respectively. Oxygen consumption by nitrification was incomplete. OUR variation of SCOD was recognizable difference of degradable rate at before and after of inflection point OUR. This study used an experimental method for real time prediction of the influent of the sewage treatment plant for optimal operation is expected to be able to do.