• Title/Summary/Keyword: Sewage treatment facilities

Search Result 164, Processing Time 0.023 seconds

Available Technology and Integrated Management Plan for Energy-positive in the Sewage Treatment Plant (에너지 생산형 하수처리장을 위한 가용 기술과 통합관리 방안)

  • Song, Minsu;Kim, Hyoungho;Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.55-68
    • /
    • 2020
  • Because of the intensified environmental problems such as climate change and resource depletion, sewage treatment technology focused on energy management has recently attracted attention. The conversion of primary sludge from the primary sedimentation tank and excessive sludge from the secondary sedimentation tank into biogas is the key to energy-positive sewage treatment. In particular, the primary sedimentation tanks recover enriched biodegradable organic matter and anaerobic digestion process produces methane from the organic wastes for energy production. Such technologies for minimizing oxygen demand are leading the innovation regarding sewage treatment plants. However, sewage treatment facilities in Korea lack core technology and operational know-how. Actually, the energy potential of sewage is higher than sewage treatment energy consumption in the sewage treatment, but current processes are not adequately efficient in energy recovery. To improve this, it is possible to apply chemically enhanced primary treatment (CEPT), high-rate activated sludge (HRAS), and anaerobic membrane bioreactor (AnMBR) to the primary sedimentation tank. To maximize the methane production of sewage treatment plants, organic wastes such as food waste and livestock manure can be digested. Additionally, mechanical pretreatment, thermal hydrolysis, and chemical pretreatment would enhance the methane conversion of organic waste. Power generation systems based on internal combustion engines are susceptible to heat source losses, requiring breakthrough energy conversion systems such as fuel cells. To realize the energy positive sewage treatment plant, primary organic matter recovery from sewage, biogas pretreatment, and co-digestion should be optimized in the energy management system based on the knowledge-based operation.

Water Quality Prediction of the Mankyung Water Shed according to Construction of New Sewage Treatment Facilities (하수처리시설 신설에 따른 QUAL2E모델에 의한 만경수계 수질예측)

  • Chung, Paulgene;Hyun, Mihee;Jung, Jinpil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.200-207
    • /
    • 2010
  • The sewage treatment plants to be built to improve the water quality of the Mankyung River will total 11, of which combined capacity will reach $39,850m^3/day$, and saying in detail, 5 at Gunsan city, 2 at Iksan city, 1 at Kimje city and 3 at Wanju gun, The scenario for water quality improvement was developed, considering the conditions of plant operation ratio and the accomplishment of the water quality target (BOD 4.4 mg/L, T-P 0.356 mg/L) at the end of the watershed of Mankyung B was predicted, making use of QUAL2E model. As a result of prediction using QUAL2E model based on scenarios with 70% and 100% of operation ratio, respectively, at 11 plants in 2010, the water quality at the watershed of Mankyung B was estimated at 4.322 mg/L which was lower than the target of BOD 4.4 mg/L, indicating the target water quality was achieved, when it comes to 70% of operation ratio, But in case of T-P, it was estimated at 0.565 mg/L, which was higher than the target. When it comes to 100% of operation ratio, T-P also was 0.563 mg/L which exceeded the target, 0.356 mg/L. As indicated above, the effect of water quality improvement appeared very insignificant, which was attributable to the limit of small scale sewage treatment plant in total reduction capacity. Hence, the measures for additional reduction in a bid to achieve the target water quality of T-P at the designated location need to be taken, and the measures to build the Sewage treatment facilities at the place where the pollution is significantly caused by T-P appeared to be required as well.

A Study on Process Improvement for Reduction of Pollution Loading Rate in Small Individual Sewage Plant (소규모 개인하수처리시설의 MBR공정 적용에 관한 연구)

  • Eom, Han Ki;Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.323-329
    • /
    • 2016
  • In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of $50m^3/day$ or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, $BOD_5$. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.

Implementations of Geographic Information Systems on Sewage Management for Water Resources Protection

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Chou, Wen-Shang;Huang, Hsiu-Lan
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1188-1190
    • /
    • 2003
  • Taipei Watershed Management Bureau (WRATB) is a government agency entitled for water resources protection at two major watersheds in order to provide drinking water for about four millions population in Taipei on a sustainable basis. At WRATB, there are two major public sewage treatment facilities which can convert sewage in each watershed into an acceptable state before they were discharged into rivers. More than 82% of household wastewater have been collected and treated by the two public sewage systems. However, households at remote area still need more effective sewage management prescriptions. The objective of this paper is to implement geographic information systems in order to provide more effective approaches that sewage management can be easier and cost effective. ArcIMS was implemented for Internet browsing and map server of those sewage facilities on personal computers, laptop computers. In the open field, ArcPAD was implemented with personal digital assistant (PDA) such that compact flash type's global positioning systems (GPS) and digital camera can be utilized with PDA. All sewage facilities digital files were convert into ArcMap format files. MapObjects and visual BASIC were used to create sewage application modules to meet every single technician personal flavor. ASP.NET was implemented for Internet database manipulations of all sewage databases. Mobile GIS was the key component of GIS applications in the open field for sewage management on a basis of house by house. Houses at remote area, which can not cover by the two public sewage systems, were managed by PDA and laptop computers with GPS and digital camera. Sewage management at Taipei Watershed Management Bureau is easier both in the open field and in the office. Integration of GPS, GIS, and PDA makes sewage management in the open field much easier. ArcIMS, MapObjects, ASP.NET and visual BASIC make sewage management can be done in the office and over Internet.

  • PDF

The improvement of the operating process of sewage treatment plants in the upstream area of dam by MASS FLOWmodelling (MASS FLOW 모델링을 통한 댐상류지역의 공공하수처리시설 공정개선방안)

  • Lee, Hyunseop;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.130-138
    • /
    • 2020
  • As of 2017, the sewerage penetration rate of Seoul and metropolitan cities is more than 90%, and the number of domestic sewage treatment plants increased by 25% from 3,064 in 2010 to 4,072 in 2017. Among them, sewage treatment plant operated by SBR system is 585, which is 17% higher than 2010. In order to improve the water quality of the water source and improve the operation of the small sewage facilities, the improvement of the process was studied by applying the modelling to 49 facilities of the sewage treatment plant in Andong Imha dam area with more than 500㎥/day 3 places and 46 places less than 500㎥/day. As an improvement plan for modelling, candidate data were derived by reviewing operation data for 5 years. 49 facilities are operated by 12 types of operating processes. Among them, 1 place mort than 500㎥/day with SBR method and 9 facilities with less than 500㎥/day were selected by dividing 46 sites into 3 types. As a result of applying modelling to more than 500㎥/day, it was possible to improve the quality of discharged water through SRT control and it was found that applying model to sites of small scale treatment plants can improve the removal efficiency of TP by up to 14.4%. As a result, the data of this study could be used to improve and improve the operation of sewage treatment plants and RCSTP(Rural Community Sewage Tratment Plant).

Wastewater-based epidemiology for the management of community lifestyle and health: An unexplored value of water infrastructure (하수기반역학을 이용한 커뮤니티 생활상 및 건강 관리: 물 인프라의 새로운 가치)

  • Jho, Eun-Hea;Kim, Hyoung-Il;Choi, Yongju;Youn, Youngho;Lee, Doyeon;Kim, Geunyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.63-77
    • /
    • 2019
  • Traditional wastewater research mainly focuses on 1) estimating the amount of waste entering sewage treatment facilities, 2) evaluating the treatment efficiency of sewage facilities, 3) investigating the role of sewage treatment effluent as a point source, and 4) designing and managing sewage treatment facilities. However, since wastewater contains a variety of chemical and biological substances due to the discharge of human excreta and material used for daily living into it, the collective constituents of wastewater are likely a reflection of a community's status. Wastewater-based epidemiology (WBE), an emerging and promising field of study that involves the analysis of substances in wastewater, can be applied to monitor the state of a defined community. WBE provides opportunities for exploiting indicators in wastewater to fulfill various objectives. The data analyzed under WBE are those pertaining to selected natural and anthropogenic substances in wastewater that are a result of the discharge of metabolic excreta, illicit or legal drugs, and infectious pathogens into the wastewater. This paper reviews recent progress in WBE and addresses current challenges in the field. It primarily discusses several representative applications including the investigation of drug consumption across different communities and the management of community disease and health. Finally, it summarizes established indicators for WBE.

Generation and Current Treatment Status of Sewage at the Rural Village in Chungnam Province (충남지역 마을하수의 발생 및 처리현황)

  • Kang, Bang-Hun;Kim, Jin-Ho;Choi, Chul-Mann
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2008
  • The purpose of this study is to investigate the current status, including the maintenance problems and removal efficiency, of small sewage treatment facilities in Chung-nam province(Asan, Buyeo, and Gongju city). Our results showed that inflow water quality of Asan city was 19.1 mg/L of BOD, 29.0 mg/L of COD, 13.4 mg/L of T-N and 1.5 mg/L of T-P, respectively, which was much higher than any other site. Among the factors known to be an important index of water quality, the SS and BOD removal efficiency was about 70% and 50% respectively. However, the nitrogen removal efficiency was less than 10%. The total removal efficiency of pollutant was 71.1% of SS, 52.6% of BOD, 46.2% of COD, 9.2% of T-P and 4.6% of T-N respectively. Therefore nitrogen removal processes are required to prevent serious eutrophication of small river. Removal efficiency for BOD and SS of high-efficient sewage treatment facilities (STFs) and contact oxidation process was much higher than another process. Performance of these sewage treatment facilities(STFs) is not optimal due to ineffective planning for the inflow water quality. To improve these facilities, it is proposed that a technical expert analysis of water quality at these facilities is periodically required.

Bioreduction Characteristics of Perchlorate in Raw Sewage (생하수의 퍼클로레이트 생분해 특성)

  • Hong, Seong Hwan;Choi, Hyeoksun
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.81-87
    • /
    • 2018
  • This research was done to investigate the bioreduction characteristics of perchlorate in raw sewage because sewage contains biodegradable organics and various microorganisms for biological perchlorate reduction. Two different types of sewage were tested for biological perchlorate reduction in the flasks. Sewage A was collected from the screening equipment and sewage B was collected from the primary settlement in the municipal wastewater treatment facilities. Perchlorate was completely reduced within 72hours from 8.2 and 10.4 mg/L in the sewage A and sewage B flask tests. When perchlorate and nitrate were added in sewage A, both perchlorate and nitrate were reduced. However, perchlorate and nitrate removal rates were 9.3% and 64.0% at 72hours in sewage B. Perchlorate reduction was significantly inhibited by high salinity(0.5% NaCl) in the sewage A and B. These results showed the sewage has potential for the biological perchlorate reduction in the sewage pipe.

Application of $ENVIS^{(R)}$ MEMBRANE SYSTEM (Sumerged flat Sheet MF Membrane) ($ENVIS^{(R)}$ MEMBRANE SYSTEM (평판형 정밀여과막)의 침지식 수처리 공정 적용에 관한 연구)

  • Lee, Young-Moo;Jang, Jae-Young
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • This study is investigated for the applications of MBR SYSTEM using $ENVIS^{(R)}$ which is a submerged flat membrane for treatment of sewage and wast water. The experiment was practiced on the scene of labor that are sewage facilities of factories $(10\;m^3/day)$ and wast water treatment plant $(30\;m^3/day)$ using equipments made by Pure-Envitech Co., LTD. SS, BOD and COD for the result of removal efficiency at the sewage facilities of factories were $99.7\%,\;97.6\%$, and $96.8\%$, rspectively. SS, BOD and COD for the result of removal efficiency at the waste water treatment plant were $99.6\%,\;95.6\%,\;and\;80.3\%$, respectively.

Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City (부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구)

  • Lee, Taeyoon;Kim, Doyong;Kim, Jaejin;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • There have been increasing interests in the odor generation problems as concerns about the quality of life has been increased recently. Especially, approximately 67% of the odor complaints from environmental facilities are those from sewage treatment facilities and food waste treatment facilities. Moreover, sewage ocean dumping will be prohibited from 2012 by the international and domestic ocean laws, and thus, demand for alternative management plans is increasing. Therefore, it was first selected 5 sewage treatment facilities and 5 food waste treatment facilities where the amounts of waste are relatively immense in Busan, and collect their sludge samples. Then it was investigated the samples' physical and chemical characteristics through proximate analysis, elemental analysis, XRF analysis, and calorific value analysis. Finally, estimate the $H_2S$ emission rates were estimated in order to apply the results as the basic data for providing the fundamental solution for the oder complaints. As a result, the concentration of $H_2S$ in sewage sludge and in food waste treatment facility were 57.3 mg/kg and 19.7 mg/kg in average, respectively. Finally, the units of $H_2S$ in wastes stored in total 10 waste treatment facilities was estimated 16,017,910.0 mg/d.

  • PDF