• 제목/요약/키워드: Sewage environment

검색결과 644건 처리시간 0.023초

Ecotoxicological Evaluation of Sewage Sludge Using Bioluminescent Marine Bacteria and Rotifer

  • Park, Gyung-Soo;Chung, Chang-Soo;Lee, Sang-Hee;Hong, Gi-Hoon;Kirn, Suk-Hyun;Park, Soung-Yun;Yoon, Seong-Jin;Lee!, Seung-Min
    • Ocean Science Journal
    • /
    • 제40권2호
    • /
    • pp.91-100
    • /
    • 2005
  • Bioassay using the marine bacteria, Vibrio fischeri and rotifer, Brachionus plicatilis, and chemical analyses were conducted to assess the toxicity of the various sewage sludges, one of the major ocean dumped materials in the Yellow Sea of Korea. Sludge elutriates extracted by filtered seawater were used to estimate the ecotoxicity of the sludge. Chemical characterization included the analyses of organic contents, heavy metals, and persistent organic pollutants in sludge. Bacterial bioluminescent inhibition (15 min), rotifer mortality (24 hr) and rotifer population growth inhibition (48 hr) assay were conducted to estimate the sludge toxicity. EC50 15 min (inhibition concentration of bioluminescence after 15 minutes exposed) values by Microtox(R) bioassay clearly revealed different toxicity levels depending on the sludge sources. Highest toxicity for the bacteria was found with the sludge extract from dyeing waste and followed by industrial waste, livestock waste, and leather processing waste. Clear toxic effects on the bacteria were not found in the sludge extract from filtration bed sludge and rural sewage sludge. Consistent with Microtox(R) results, rotifer neonate mortality and population growth inhibition test also showed highest toxicity in dyeing waste and low in filtration bed and rural sewage sludge. High concentrations of persistent organic pollutants (POPs) and heavy metals were measured in the samples from the industrial wastes, leather processing plant waste sludge, and urban sewage sludge. However, there was no significant correlation between pollutant concentration levels and the toxicity values of the sludge. This suggests that the ecotoxicity in addition to the chemical analyses of various sludge samples must be estimated before release of potential harmful waste in the natural environment as part of an ecological risk assessment.

회귀식을 사용한 하수처리장 방류수 CODMn 농도의 총 유기탄소 및 난분해성 물질 농도 전환 (Conversion of CODMn into TOC and Refractory Organic Matter Concentrations for Treated Sewage using Regression Equations)

  • 이태환;이보미;허진;정명숙;강태구
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.969-975
    • /
    • 2010
  • Estimating the organic matter loadings from individual treated sewage has become important for establishment of effective management strategies to control refractory organic matter (R-OM) in watersheds. For this study, regression equations were constructed using treated sewage data to convert the chemical oxygen demand (COD) concentrations, which are mostly available from open database, into total organic carbon (TOC) and R-OM concentrations. Effluent samples were collected from five major sewage treatment plants (STPs) located upstream of the lake Paldang. Variations in the OM concentrations were not associated with either the location of the STP or the sampling season. The effluent investigated were characterized by higher ratio of R-OM with respect to biodegradable organic matter (B-OM) and higher presence of dissolved organic matters (DOM) versus particulate organic matter (POM). Compared to $COD_{Mn}$, $COD_{Cr}$ exhibited higher oxidation efficiencies and greater variations in the concentrations. The concentrations of $COD_{Mn}$ were positively correlated with dissolved organic carbon (DOC), total organic carbon (TOC), and R-OM concentrations. There was nearly no seasonal and annual variation in the regression equations between $COD_{Mn}$ and TOC or R-OM concentrations. The constructed regression equations for TOC and R-OM were $0.650({\pm}0.071){\times}COD_{Mn}+1.426({\pm}0.575)$ and $0.340({\pm}0.083){\times}COD_{Mn}+2.054({\pm}0.670)$, respectively. The established equations are expected to contribute to estimating OM loadings from the STPs into the lake Paldang and also to compensating for the deficiency of the data for effluent OM concentrations in STP.

분변계 스테롤을 이용한 남해안 패류양식어장(여자만과 강진만)의 퇴적물내 분변오염도 평가 (Sterols as Indicators of Fecal Pollution in Sediments from Shellfish Farming Areas (Yeoja Bay and Gangjin Bay) of Korea)

  • 최민규;이인석;황동운;김형철;김예정;김숙양
    • 한국수산과학회지
    • /
    • 제46권4호
    • /
    • pp.437-444
    • /
    • 2013
  • Eight fecal sterols were analyzed in surface sediments collected from shellfish farming areas in Yeoja Bay and Gangjin Bay, Korea, to evaluate sewage-derived fecal pollution. The concentrations of coprostanol, a good marker of sewage-derived organic contamination, in sediments were in the range of 10-530 ng/g-dry in Yeoja Bay, and 10-190 ng/g-dry in Gangjin Bay. Coprostanol levels were markedly higher in the inner bay than in the outer bay. These levels were lower than those reported in urbanized bays in Korea, however, they were comparable to levels in other shellfish farming areas including Gamak Bay. A multivariate analysis of the ratios of other sterols suggested that the sterols originated from sewage and plankton/benthos. Sewage was the dominant source at stations located close to the river mouth and wastewater treatment plant (WWTP) outfalls, and plankton/benthos was the primary source in the outer bay. These results suggest that management of point sources, e.g., WWTP as well as non-point sources, e.g., riverine inputs is important for improving the water quality in Yeoja Bay and Gangjin Bay.

다단토양층을 이용한 하수처리에 관한 연구 (Study of Sewage Treatment using Multi-soil-layering System)

  • 손대희;정윤철;신정훈;정진영;안대희
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.

A Fuel Feasibility Study of Sewage Sludge by Melting of Thermoplastic Polyethylene

  • Lee, Byeong-Kyu;Jeong, Wang-Seok
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.9-16
    • /
    • 2010
  • This pilot study evaluated fueling feasibility of sewage sludge, which contains a large amount of water content, by applying melting of thermoplastic polyethylene (PE). This study has identified a simultaneous achievement of drying and heating value improvement of the sewage sludge. The sewage sludge collected from a sewage sludge treatment plant during a winter period had a water content of 83.7 wt%, a combustible volatile content of 12.5 wt%, and an ash content of 3.8 wt%. The higher heating value (HHV) of the dried sewage sludge, before impregnation or coating of PE, was 4,600 kcal/kg. The collected sewage sludge was immersed into the melted PE solution, which had a HHV of 11,070 kcal/kg, and kept immersing with increasing reaction time. As the reaction (immersing or coating or impregnation) time increased, the water content of the sludge decreased. However, the HHV of the sludge increased with increasing the reaction time. The HHVs of the sewage sludge immersed or dipped into the melted PE solution for 15 min ranged from 6,780 to 8,170 kcal/kg with water content less than 7 wt%. This result indicates the melted PE solution can be utilized as an improvement technology for dryness and heating value of the sewage sludge with high water content. The sewage sludge impregnated or coated with melted PE can be utilized as potential fuel or energy resources.

기존 하수처리장 성능개선을 위한 NPR공정의 적용 (An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant)

  • 문태훈;고광백;송의열
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

하수처리장 방류수에서 TOC와 COD 유기물관리 (Management of TOC and COD Organic Matter of Effluents in Sewage Treatment Plants)

  • 황석호;박제철
    • 한국환경과학회지
    • /
    • 제27권4호
    • /
    • pp.261-266
    • /
    • 2018
  • In this study, the organic matter of effluents from sewage treatment plants, located in the Nakdong watershed was investigated. Regression equations were computed using treated sewage data to convert the chemical oxygen demand(COD) concentrations, which are mostly available from an open database, into total organic carbon(TOC) concentrations. The average concentration of organic matter in the sewage treatment plant effluents were 2.2~16.8 mg/L for COD and 3.4~14.3 mg/L for TOC. The concentrations of COD were positively correlated with the TOC concentrations. The correlation between COD and TOC was relatively high, at 0.865(p<0.01). Based on these results, regression analysis was conducted. The regression equation for TOC was $1.651{\times}COD_{Mn}-0.084$ ($R^2=0.84$). Furthermore, organic matter-related databases for more sewage treatment plants need to be built in order to establish TOC standards and manage the water quality.

환경기초시설 운영비 보조와 오염원인자부담원칙 (Relationship Between Environmental Infra Operating Cost and Polluter Pay Principles)

  • 강희찬;강성원;김민준
    • 자원ㆍ환경경제연구
    • /
    • 제24권1호
    • /
    • pp.165-187
    • /
    • 2015
  • 본 연구는 수계기금의 환경기초시설 운영비 지원이 지방자치단체의 하수도요금 현실화를 억제하여 수질개선에 역행하는 부작용이 있는지 여부를 분석하는 연구이다. 이를 위해 본 연구에서는 2009~12년 기초지방자치단체의 하수도요금 및 수계기금 지원금 간의 관계를 2단계 최소자승법(Two-Stage Least Squares)을 이용하여 분석하였으며, 이를 통해 수계기금의 환경기초시설 설치 및 운영비용 지원이 하수도요금 현실화를 억제하는 역(逆)인센티브 효과가 있는지 점검하였다. 연구 결과 수계기금 지원금이 하수도요금 현실화 노력에 부정적인 영향을 미치고 있다는 것을 발견하였다. 그러나 이 효과는 통계적인 유의성이 모형에 따라 민감하게 변화하였으며, 전반적으로 그 값이 크지 않아 수계기금의 환경기초시설 설치 운영비 지원이 하수도요금 현실화율에 미치는 영향은 미미하였음을 확인하였다.

강릉시 콘크리트 하수관거의 내구성 평가 (Estimation on Durability of Concrete Sewage in Kangnung City)

  • 최성하;최윤석;김강래;김명유;양은익
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.229-232
    • /
    • 2006
  • Most of sewage in our country has been made by concrete, and currently they shows gradual deterioration. One of serious problems happened in the sewage is a corrosion of sewage itself. Namely, biochemical corrosion is the most important one. Deterioration phenomenon in concrete used in sewage is occurred by environment condition of sewage, such as erosion by the acid, erosion by sulfate, corrosion by carbonation and so on several factors. However, at present, investigation data on durability of Kangnung city sewage is not sufficient. In addition, the prediction of repair time and selection of rehabilitation method is also not easy. Accordingly, in this research, investigation on durability of sewages located in Kangnung city was carried out. It will also supply the basic data for repair and rehabilitation.

  • PDF