• Title/Summary/Keyword: Sewage/wastewater reuse

Search Result 37, Processing Time 0.027 seconds

Colonization of Microbial Biofilms in Pipeline of Water Reuse

  • Kumjaroen, Teratchara;Chiemchaisri, Wilai;Chiemchaisri, Chart
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2014
  • Aim of this study was to investigate biofilms attached in pipeline of water reuse from the MBR system treating sewage without chlorination in correlation to the outflow water quality. Two general pipe materials: polyvinyl chloride (PVC) and polyethylene (PE) were employed in the experiment. The peak growths were found at week 4 in both pipes. The maximum biofilms in PE pipe was $33mgVSS/cm^2$ with the growth rate of $4.75mgVSS/cm^2-d$ which was significant higher than that of PVC pipe. Biofilms examined by PCR-DGGE technique revealed five bacterial species in PE biofilms namely Sinorhizobium medicae WSM419, Sinorhizobium fredii NGR234, Geobacter sp. M18, Parachlamydia acanthamoebae UV-7, and Mycobacterium chubuense NBB4. The VSS concentrations in outflow had directly correlated to the biofilm attachment and detachment. High COD concentrations of outflow appeared during biofilm detaching phase. In summary, water quality of reuse water corresponded to the biofilms attachment and detachment in the pipeline.

Urban Instream Flow Augmentation Using Reclaimed Water in Korea (하수처리수 재이용을 통한 도시하천 물순환 및 수질 개선)

  • Jee, Yong-Keun;Ahn, Jong-Ho;Lee, Jin-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.285-294
    • /
    • 2012
  • Current urban stream conditions and their restoration projects were investigated by surveying the urban stream management experts in 29 cities with high population density (more than 1,000person/$km^{2}$). The survey results showed that the ratio of covered urban streams decreased by 1.4% (from 14% to 12.6%) in the last 5 years through steady river restoration projects promoted by governments. Nonetheless, 36.3% of 369 urban streams surveyed still report stream depletion problems; therefore, more efforts to alleviate the problems caused by distorted water circulation of urban streams are still necessary. Water depletion in many local urban streams, unlike national rivers, is accelerated due to negligence in stream management, budget shortage, and other reasons. To prevent stream depletion, the use of reclaimed water is suggested as one of the prevention plans. When available amounts of reused sewage are estimated through actual available nationwide sewage discharges of each watershed and instream flow of stream, annual instream flow supply of 780 million $m^{3}$ is expected; 4.8% reduction in the pollution load of public sewer treatment facilities is expected; and the creation of new value through water reuse service is expected. Thus, it is important for the reviews of feasibility and alternatives of water reuse projects for flow augmentation to consider not only investment budget reductions, but also environmental aspects. Also it is necessary to provide the financial support of unified government with strict water quality management policy.

Effect of Indirect Oxidation on the Design of Sewage/wastewater Reuse System with an Electrolysis Reactor (전기분해 반응조의 간접산화 효과가 하.폐수 재활용 시스템 설계에 미치는 영향)

  • Shin, Choon-Hwan
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • In this paper, we investigated the effect of an indirect oxidation zone in an electrolysis reactor that used Ti/$IrO_2$ as the anode and SUS 316L as the cathode. Based on our preliminary results, the electrolysis reactor was operated with pole plate interval of 6 mm, current density 1.0 $A/dm^2L$ and electrolyte concentration 15%. The removal efficiency, COD (chemical oxygen demand), was additionally increased by 55% and 12.5${\sim}$15.0% in the direct and indirect oxidation zones, respectively. The removal efficiencies of T-N (total nitrogen) and T-P (total phosphorus) were found to be 88% and 75%, respectively. It was shown that the additional effect of the indirect oxidation zone on the removal was nearly negligible. Also, as the removal of COD,T-N and T-P took place during the initial2${\sim}$5 days of reaction, it was concluded that there was no need to extend the retention time of the electrolysis reactor.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

A study on the composition validity of performance indicators for public sewage treatment plant by using factor analysis (요인분석기법을 활용한 공공하수처리시설 성과평가 지표의 구성 타당성 연구)

  • Yoon, Cheon-Yeo;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.583-590
    • /
    • 2015
  • Evaluation and comparison for the performance on the contracting-out became possible after the introduction of the performance indicators(PIs) in 2012 in Korea, And local governments and private companies are utilizing them as evaluation data to enhance the performance of the contracting-out. Several revisions on performance indicator were carried out by expert group on contents validity of PIs, But the review of the composition validity of PIs was not sufficient. In this study, the applicability, distinction ability and composition validity of PIs is evaluated by statistical method. From the results, Improvement of indicator is required in order to increase the interrelationship among indicators to enhance the compostion validity of indicators related with operation, sludge and water reuse.

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

Reuse of Reclaimed Water for Irrigation on Paddy Rice Culture and Its Effect

  • Chun G. Yoon;Ham, Jong-Hwa;Jeon, Ji-Hong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.7
    • /
    • pp.14-24
    • /
    • 2002
  • The effect of reclaimed water irrigation on paddy rice culture was evaluated by pilot study at the experimental field of Konkuk University in Seoul, Korea. The sewage was treated by constructed wetland system, and its effluent was used as irrigation water for four treatments and one control plots with three replications. Irrigation of reclaimed water onto paddy rice cultures did not adversely affect the growth and yield of rice. Instead, experimental rice plots of reclaimed water irrigation displayed about 10 to 50% more yield on average than controls. This implies that reclaimed water irrigation might be beneficial rather than harmful to rice culture as long as the sewage is treated adequately and used properly. The amount of irrigation water had little effect on experimental rice cultures, but its strength was important. The strength of treated sewage was not a limiting factor in this study, and no lodging was observed even with a relatively high nitrogen concentration (up to 160mg/L). In general the paddy soil was not affected by reclaimed water irrigation. However, there was an indication that continuous irrigation with high strength of reclaimed water might cause salt accumulation in the soil. Supplemental use of reclaimed water with existing sources of irrigation water is recommended rather than irrigation with a single source of reclaimed water. Overall, the results demonstrated that reclaimed water could be reused as a supplemental source of irrigation water for paddy rice culture without causing adverse effects as long as it is properly managed. For full-scale application, further investigation should be done on environmental risks, tolerable water quality, and fraction of supplemental irrigation.

A Study on the Estimation of Irrigation Water for Sewage Treated Water Reuse for Agriculture (하수처리수의 농업용수 재이용을 위한 관개수량 산정방법에 관한 연구)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • The purpose of this study was to establish the estimation method of irrigation water amount for sewage treated water reuse for agricultural purpose. To calculate the irrigation water amount, we adopted Penman-Monteith for potential evapotranspiration estimation and applied crop coefficient and irrigation efficiency factor. We developed the irrigation water amount calculation program using C language in Xcode environment. The target district for calculation is having 259 ha of agricultural land located near the Jinyeong Clear Water Circulation Center in Hanrim-myeon, Gimhae city. The meteorological data of the study area were obtained from Changwon weather station from 1986 to 2017. Calculated average and maximum of annual mean potential evapotranspiration were 2.72 mm/day and 6.22 mm/day, respectively. We used K-S (Kolmogorov-Smirnov) for goodness-of-fit test to find optimal probability distribution of annual mean and maximum evapotranspiration. As a result, the normal distribution was selected for the appropriate distribution. The annual mean and maximum potential evapotranspiration for 10-year return period by applying normal distribution were 2.88 mm/day and 6.76 mm/day, respectively. Assuming that the irrigation efficiency is 80%, the irrigation water requirement was calculated as $36.05m^3/day/ha$ and $84.45m^3/day/ha$, respectively, when annual mean and maximum potential evapotranspiration were applied. The actual irrigation water amount can be calculated by applying the crop coefficient and cropping days for the study area based on the developed irrigation water amount estimation program in this study.

Status, Trend and Strategy on Municipal Wastewater Management in China

  • Wang, Baozhen;Wang, Lin;Liu, Shuo;Wang, Li;Wang, Zheng
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.47-60
    • /
    • 2007
  • The rapid development of economy in China at the expense of consuming huge amount of energy and resources, water resource in particular, which has resulted in the production and discharge of increasing amount of wastewater to the water environment. In order to effectively control the increasing water pollution trend, the State Council has stipulated that all the cities with population over 500,000 should reach wastewater treatment rate of 60% by 2005, and all the cities should reach the rate of 60% by 2010, of which Capital Beijing and all the province capital cities and important tourism cities should reach 70% then. By the end of 2005, of the 661 cities in China, 393 have built and operated municipal wastewater treatments with a total number of 790 sets, total treatment capacity of $80.91{\times}106m^3/d$ and total treatment rate of > 48%. Other 73 cities have started the construction of municipal wastewater treatment plants, and other 168 cities have started to prepare, planning and design of wastewater treatment plants. Most of municipal wastewater treatment plants in big cities in China operate normally and perform well with good quality of effluent in terms of wastewater treatment train, but the sewage sludge treatment is usually poor with big problems. It has been found that the small scale WWTPs using activated sludge process in the towns are usually operated and maintained abnormally because of lack of fund, skilled operators and energy. It is therefore suggested that the small scale MWWTPs in small cities and towns adopt appropriate technologies, of which the most available ones are multi-stage ponds, constructed wetlands and the combination of them for further purification and reuse of treated wastewater.

  • PDF

Forward Osmosis Membrane to Treat Effluent from Anaerobic Fluidized Bed Bioreactor for Wastewater Reuse Applications (하수재이용을 위한 혐기성 유동상 생물반응기 처리수의 정삼투 여과막의 적용)

  • Kwon, Dae-eun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.196-204
    • /
    • 2018
  • The anaerobic fluidized bed bioreactor (AFBR) treating synthetic wastewater to simulate domestic sewage was operated under GAC fluidization to provide high surface area for biofilm formation. Although the AFBR achieves excellent COD removal efficiency due to biological activities, concerns are still made with nutrient such as nitrogen remaining in the effluent produced by AFBR. In this study, forward osmosis membrane was applied to treat the effluent produced by AFBR to investigate removal efficiency of total nitrogen (TN) with respect to the draw solution (DS) such as NaCl and glucose. Permeability of FO membrane increased with increasing DS concentration. About 55% of TN removal efficiency was observed with the FO membrane using 1 M of NaCl of draw solution, but almost complete TN removal efficiency was achieved with 1 M of glucose of draw solution. During 24 h of filtration, there was no permeate flux decline with the FO membrane regardless of draw solution applied.