• 제목/요약/키워드: Settling Efficiency

검색결과 172건 처리시간 0.025초

분산성 염료의 제거를 위한 응집처리 (Chemical Precipitation Treatment for the Disperse Dyes Removal)

  • 한명호;박종득;허만우
    • 한국염색가공학회지
    • /
    • 제14권2호
    • /
    • pp.40-50
    • /
    • 2002
  • In order to remove the pollutants effectively in the dye wastewater by chemical precipitation process, coagulation arid flocculation test were carried out using several coagulants on various reaction conditions. It was found that the Ferrous sulfate was the most effective coagulant for the removal of disperse dye(B79), and we could get the best result lot the removal of disperse dye(B56) in the aspects of TOC removal efficiency and sludge field. When the Ferrous sulfate dosage was $800mg/\ell$, the sludge settling velocity was very fast>, and the color was effectively removed in the disperse dye(B79) solution. Although the color removal was ineffective when the Alum was used as a coagulant, the sludge field was decreased in comparison with the Ferrous sulfate or the Ferric sulfate was used in the disperse dye(B56) solution. The general color removal effect for the disperse dye(B56 and B79) solutions, the Ferric sulfate was more proper coagulant than the Alum. It was showed that TOC removal was improved 5% and over by the addition of Calcium hydroxide, and $30mg/\ell$ of sludge yield was decreased(B79). When Alum or Ferric sulfate was used as a coagulant, pH condition for most effective color removal was 5 in B56 solution. In case of Ferrous sulfate as a coagulant, most effective pH condition for color removal was 9. When Ferric sulfate or Ferrous sulfate was used as a coagulant, pH condition for most effective color removal was 9 in B79 solution.

수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리 (Piggery Waste Treatment using Improved MLE Process in Full-Scale)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

트랙터의 기관속도(機關速度) 및 변속비(變速比)의 자동제어(自動制御)에 관(關)한 연구(硏究)(I) -기관속도(機關速度) 및 변속비(變速比) 제어(制御) 시스템- (Automatic Control of Engine Speed and Transmission Ratio for Efficient Tractor Operations(I) -Control Systems for Engine Speed and Transmission Ratio-)

  • 강성봉;류관희;오길근
    • Journal of Biosystems Engineering
    • /
    • 제18권4호
    • /
    • pp.305-316
    • /
    • 1993
  • Fuel efficiency in tractor operations dep6nds on the selection of transmission gears and upon the engine being operated at or near maximum torque much of time. The objective of this study was to develop automatic control systems for tractor transmission ratio and governor setting so that the engine is operated at or near maximum torque as much of time as possible. An indoor test unit, which can be used to simulate tractor operation, was built in order to investigate the system design parameters and test the performance of the control system designed. The test-unit consists of engine, gear-type transmission, dynamometer, and control systems for transmission ratio and engine speed. Governor setting lever was controlled by a step motor, and the clutch and transmission levers were controlled by hydraulic cylinders and solenoid valves. The control systems showed good time responses which are assumed to be suitable for optimal tractor operation. The time required for shifting gears from clutch disengagement to engagement was about 1 second, which is almost the same as that for manual shift. And the settling time for engine speed control system was about 5 to 6 seconds.

  • PDF

강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향 (Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall)

  • 어성욱;김건하;손봉호
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.

250 mV Supply Voltage Digital Low-Dropout Regulator Using Fast Current Tracking Scheme

  • Oh, Jae-Mun;Yang, Byung-Do;Kang, Hyeong-Ju;Kim, Yeong-Seuk;Choi, Ho-Yong;Jung, Woo-Sung
    • ETRI Journal
    • /
    • 제37권5호
    • /
    • pp.961-971
    • /
    • 2015
  • This paper proposes a 250 mV supply voltage digital low-dropout (LDO) regulator. The proposed LDO regulator reduces the supply voltage to 250 mV by implementing with all digital circuits in a$0.11{\mu}m$ CMOS process. The fast current tracking scheme achieves the fast settling time of the output voltage by eliminating the ringing problem. The over-voltage and under-voltage detection circuits decrease the overshoot and undershoot voltages by changing the switch array current rapidly. The switch bias circuit reduces the size of the current switch array to 1/3, which applies a forward body bias voltage at low supply voltage. The fabricated LDO regulator worked at 0.25 V to 1.2 V supply voltage. It achieved 250 mV supply voltage and 220 mV output voltage with 99.5% current efficiency and 8 mV ripple voltage at $20{\mu}A$ to $200{\mu}A$ load current.

Fluoride removal using Alum & PACl in batch & continuous mode with subsequent microfiltration

  • Dubey, Swati;Agarwal, Madhu;Gupta, A.B.
    • Membrane and Water Treatment
    • /
    • 제12권2호
    • /
    • pp.83-93
    • /
    • 2021
  • In this study, defluoridation efficiency by aluminium sulphate (alum) and polyaluminium chloride (PACl) were compared for recommended Nalgonda dose (100%) and 80% of this dose in both batch and continuous modes. The residual turbidity was found to be higher in case of alum as compared to PACl with 80% dose representing lesser efficient settling of suspensions, which primarily comprise alumino-fluoro complexes that result in high residual aluminium in the treated water and this was confirmed by TEM and Zeta analysis. Moreover, the application of PACl also resulted in much lesser addition to the TDS and also required lesser lime for pH compensation due to its lower acidity. Hence this reduced dose was recommended for defluoridation. It was also observed that in case of alum, residual aluminium in treated water was 0.88 mg/L (100% dose) & 0.72 mg/L (80% dose) and in case of PACl, it was 0.52 mg/L(100% dose) & 0.41 mg/L(80% dose). After subsequent microfiltration, residual aluminium was 0.28 & 0.21 mg/L for 100% & 80% dose respectively and in case of alum and in case of PACl, it was 0.16 & 0.11 for 100% & 80% dose respectively, which conform to the Al standards(<0.2 mg/L).

MOUSE TRAP 모델을 이용한 하수관거내 수질변화 예측 (Estimation of Water Quality Variation in Sewer Network using MOUSE TRAP Model)

  • 양해진;전항배;손대익
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.743-752
    • /
    • 2009
  • One of the major problems associated with operation of domestic sewer lines involves hydraulic problems such as insufficient conveyance capacity, exceeding maximum velocity, and deficiency of minimum velocity. It has also been pointed out that influent concentration lower than design concentration of pollutants, which is mainly caused by unidentified inflow and infiltration, degrades the operational efficiency of many sewage treatment plants (STPs). A computer-added analysis method supporting a coupled simulation of sewage quality and quantity is essentially required to evaluate the status of existing STPs and to improve their efficiency by a proper sewer rehabilitation work. In this study, dynamic water quality simulations were conducted using MOUSE TRAP to investigate the principal parameters that governs the changes of BOD, ${NH_4}^+$, and ${PO_4}^{3-}$3- concentrations within the sewer networks based on data acquired through on-site and laboratory measurements. The BOD, ${NH_4}^+$ and ${PO_4}^{3-}$3- concentrations estimated by MOUSE TRAP was lower than theoretical pollution loads because of sedimentation and decomposition in the sewer. The results revealed that sedimentation is a most important factor than other biological reactions in decreasing pollutant load in the sewers of C-city. The sensitivity analysis of parameters pertaining to water quality changes indicated that the effect of the BOD decay rate, the initial DO concentration, the half-saturation coefficient of dissolved BOD, and the initial sediment depth is marginal. However, the influence of settling rate and temperature is relatively high because sedimentation and precipitation, rather than biological degradation, are dominant processes that affect water quality in the study sewer systems.

인공습지의 비용 효율적 초기 침강지 설계를 위한 최적 도류벽 구조 모의 (Simulation of Various Baffle to Improve Settling Efficiency in Constructed Wetland using CFD)

  • 노태균;전제찬;김이형
    • 한국습지학회지
    • /
    • 제19권4호
    • /
    • pp.451-458
    • /
    • 2017
  • 본 연구에서는 비용효율적인 인공습지의 설계를 위하여 초기 침강지 내 다양한 도류벽형태에 따른 인공습지의 사수역 및 입자상 물질의 제거효율을 전산유체역학(Computational Fluid Dynamics, CFD)을 통해 연구하였다. 그 결과, 초기 침강지에서 도류벽의 형태는 유입 유속에 영향을 미치며, 침전률에도 큰 영향을 미치는 것으로 분석되었다. $2{\mu}m$$5{\mu}m$와 같은 미세한 입자에서는 수평으로 설치한 도류벽에서 침전률이 높았으며, $10{\mu}m$$20{\mu}m$ 크기의 큰 입자는 수직형 도류벽에서도 높은 침전률을 나타내었다. 또한, 수직형 도류벽의 경우 좁은 면적에 침전이 집중적으로 이루어지기에 다른 형태에 비해 유지관리가 효율적일 것으로 판단되었다. 이에 인공습지의 설계 목적에 따라 가장 적절한 도류벽의 형태를 선정하여 설계해야 할 것으로 보여진다.

강우시 하수처리장 일차침전지 월류수 처리를 위한 고효율응집시스템의 적용성 평가 (A Performance Evaluation of the Highly Efficient Coagulation System for the Treatment of Overflows from Primary Clarifier in WWTP)

  • 권은미;오석진;김흥섭;조성주;이승철;하성룡;임채환;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.391-398
    • /
    • 2011
  • This study is to develop highly efficient coagulation system(HECS) that runs treatment with a short retention time to cover the overflow in the rain, which coagulation, mixing and settling are contacted in a single reactor and to estimate the applicability. Setting up 100ton/day-size pilot scale plant, the results of continuous operation in case of runoff, maintaining 20 minute-retention time at optimum chemical injection condition(Alum 100mg/L, Polymer 1.0mg/L) shows the highest removal efficiency(Turbidity 93.1%, TCODcr 80.6%, BOD 81.8%, SS 92.5%, TN 72.3% and T-P 87.3%). It was estimated that the large amount of cost for separate sewage system and the size of area for system instruction can be reduced if the HECS is applied for CSOs treatment because the HECS is so compact and quickly. When we see the results, HECS from this study could be able to treat the pollutant quickly within a short retention time only with coagulant and polymer, which could show high applicability.

고밀도 뱀장어 양식수조의 질병대책 (Fish Diseases and Their Control in High Density Culture of Eel)

  • 전세규
    • 한국수산과학회지
    • /
    • 제16권2호
    • /
    • pp.103-110
    • /
    • 1983
  • The main purpose of the present study is to evaluate a revolving plate type biofilter system for mass culture of eel(Anguilla japonica) based on the experimental rearing for 120 days (Oct. 1982-Feb. 1983). Water quality changes, growth efficiency of fish and fish disease treatment were critically evaluated. A revolving plate type biofilter system was designed(Fig. 1). The system consisted of a glass tank (150 l), a revolving plate biofilter and a settling tank(150 l). The biofilter consisted of 60 submerged quadriangular plates ($28{\times}37$ cm) and 30 revolving plates (32 cm diameter) for a total of 19.0 $m^2$ of surface area. The revolving plates were made to rotate 10 time per minute, The total water volume of the rearing system were 300 l, and everyday 1/3 of the total water volume were changed with freshly prepared water. In the rearing system a total of 2 kg of eel (1,500 individuals, mean weight:1.3 g) were reared fed on the pellet feed and the dough feed. The growth efficiency were much better for the pellet feed (FC: 1.79) compared to the dough feed (FC: 3.56). During the experimental rearing water quality control was satisfactory. Total ammonia concentrations were 0.38-0.59 ppm and nitrite concentration were 0.83-1.19 ppm. On the other hand alkalinity decreased from 176ppm just after the water change to 17ppm just before the water change. The low alkaline condition was compensated by the regular change of water. Epidemics of parasitic gill-flocks (Pseudodactvlogylus sp.) was observed, and they were easily eliminated by the treatment of DDVP (1.0 ppm). Trichodina sp. and Costia sp. were observed, and they were also controlled by the treatment of potassium permanganate (4.0 ppm).

  • PDF