• 제목/요약/키워드: Setting parameters

Search Result 508, Processing Time 0.027 seconds

The Process Control Using Modeling Technique in A2O Sewage Treatment Process (모델링기법을 이용한 A2O 하수처리공정에서 주요 공정관리에 관한 연구)

  • Park, Jung Soo;Kim, Sung Duk;Seung, Dho Hyon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.2
    • /
    • pp.65-75
    • /
    • 2020
  • The efficiency of sewage treatment was ananlyzed selecting a sewage treatment plant in Gyeonggi-do where A2O process was applied. Statistical techniques based on the operation data of the sewage treatment were used. The main factors directly affecting the efficiency of the treatment process were analyzed using a GPS-X model. The correlation analysis and one-way ANOVA were performed. The T-N and NH4+-N values of the effluent did not generate statistically significant level (p-value:>0.05) when compared with C/N ration values. Removel of nitrogen components form sewage treatment plants were affected by temperature, HRT, SRT and DO. In the case of BOD, all operating factors were affected, while COD was affecte by factors of HRT, STR and DO. In simulations using GPS-X, the parameters that greatly influence was included the maximum sedimentation rate, the dependent nutrient microbial yield (anoxic), the phosphorus saturation coefficient, the dependent nutrient microbial killing rate, the dependent nutrient microbial maximum growth rate, and the independent trophic microorganisms. The maximum growth rate and the maximum setting rate were identified.

development of a Depth Control System for Model Midwater Trawl Gear Using Fuzzy Logic (퍼지 논리를 이용한 모형 증층트롤 어구의 수심제어시스템 개발)

  • 이춘우
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.54-59
    • /
    • 2000
  • This paper presents a control system that uses a fuzzy algorithm in controlling the depth of a model midwater trawl net, and experimental results carried out in the circulating water channel by using a model trawl winch system.The fuzzy controller calculates the length of the warp to be changed, based on the depth error between the desired depth and actual depth of the model trawl net and the ratio of change in the depth error. The error and the error change are calculated every sampling time. Then the control input, i.e. desirable length of the warp, is determined by inference from the linguistic control rules which an experienced captain or navigator uses in controlling the depth of the trawl winch controller and the length of the warp is changed. Two kinds of fuzzy control rules were tested, one was obtained from the actual operations used by a skilled skipper or navigator, and the other was a modified from the former by considering the hydrodynamic characteristics of the model trawl system.Two kinds of fuzzy control were tested, one was obtained fro the actual operations used by a skilled skipper or navigator, and the other was a modified from the former by considering the hydrodynamic characteristics of the model trawl system.The results of these model experiments indicate that the proposed fuzzy controllers rapidly follow the desired depth without steady-state error although the desired depth was given in one step, and show robustness properties against changes in the parameters such as the change of the towing sped. Especially, a modified rule shows smaller depth fluctuations and faster setting times than those obtained by a field oriented rule.

  • PDF

The Effects of a Worksite On-line Health Education Program on Metabolic Syndrome Risk Factors and Nutrient Intakes of Male Workers (온라인 건강교육프로그램이 남성근로자의 대사증후군 위험요인 및 영양소 섭취에 미치는 영향)

  • Kang, Ji-Yeon;Cho, Sang-Woon;Lee, Ji-Young;Sung, Sook-Hee;Park, Yoo-Kyoung;Paek, Yun-Mi;Choi, Tae-In
    • Journal of Nutrition and Health
    • /
    • v.43 no.1
    • /
    • pp.57-68
    • /
    • 2010
  • Worksite health promotion programs have been associated with reductions in health risks but are labor-intensive and costly to implement. Therefore, innovative strategies to provide a cost-effective approach to health education program are needed. The purpose of this study was to investigate the effects of a worksite on-line health education program by email on metabolic syndrome risk factors and dietary intakes in male workers with metabolic syndrome. Anthropometric and biochemical parameters were measured and the nutrient intakes were assessed through FFQ. The diagnosis of metabolic syndrome was adapted from NCEP-ATP III with blood pressure, fasting blood glucose, triglyceride, HDL cholesterol, and Asia-Pacific definition with waist circumference. The education group consisted of 212 male workers and the non-education group of 236 age-matched male workers. The on-line health education program provided 10 sessions by e-mail. After a worksite on-line health education program, systolic blood pressure (p < 0.001), diastolic blood pressure (p < 0.001) and fasting blood glucose (p < 0.001) were significantly decreased and HDL cholesterol (p < 0.001) was significantly increased in the education group. Intakes of total energy (p < 0.05), carbohydrate (p < 0.05), sodium (p < 0.05) were significantly decreased in the education group, but there were no significant differences in dietary intakes in the non-education group after a worksite on-line health education program. The results indicate that online health education program by e-mail is effective for improving metabolic syndrome risk factors and dietary intakes in male workers and show potential for use in the working setting.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

Investigation of the Acoustic Performance of Music Halls Using Measured Radiation Characteristics of the Korean Traditional Musical Instruments (국악기의 음향방사특성에 따른 국악당의 음향성능조사)

  • Haan Chan-Hoon;Lee Wangu;Jeong Cheol-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.469-480
    • /
    • 2005
  • There have been always some difficulties in target setting and conditioning of acoustic performances or the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. As the 2nd experiment succeeding the previous study[1], the radiation characteristics of eight typical Korean traditional musical sources were investigated if precision. The selected musical sources were Geomungo, Haegeum (string), Piri, Taepyeongso (woodwind), Buk, Kwaengguari, Jing (drum), and male Pansori Chang (vocal Performance). The results show that the directivity pattern of each instrument is different and has their own directivity characteristics. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. In order to investigate the acoustical characteristics of the instruments depending on the spatial variation four different shapes of halls were introduced including rectangular, fan. horse-shoe and geometrical shapes. Room acoustical parameters such as RT, SPL, C80, LF, STI were calculated at each type or hall. As the results, It was found that the rectangular hall has the most high clarity. lateral energy and STI values among low shapes of halls. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

Efficacy Evaluation of Anti-wrinkle Products in Japan

  • Masaki Hitoshi
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.29 no.2 s.43
    • /
    • pp.67-77
    • /
    • 2003
  • Two categories of cosmetic products, cosmetics and quasi-drugs, have been established by the Ministry of Health, Labor and Welfare (MHLW) in Japan. Japanese pharmaceutical law has defined that products categorized as cosmetics do not exhibit any effects on human skin. In fact, cosmetic products are not permitted to claim any efficacy. On the other hand, products in the quasi-drug category can claim several efficacies such as anti-inflammatory effects, whitening/lightning effects, hair growth effects and so on. Unfortunately, the Japanese MHLW has not yet approved the efficacy of anti-aging/anti-wrinkle effects as a claim point. However, the population is aging, and the demand for anti-aging/anti-wrinkle products is increasing year by year. Japanese cosmetic companies have proposed to the MHLW that anti-aging/anti-wrinkle agents be approved as a claim concept of a quasi-drug. However, unified evaluation methods for anti-aging/anti-wrinkle effects have not been established. Currently, each company evaluates the efficacy of products/materials using their own original methods. Thus, to request approval of the MHLW, the establishment of a unified evaluation method is needed. Consequently, the Japan Cosmetic Industry Association (JCIA) has established a task force to develop guidelines for evaluating anti-wrinkle effects in 1998. In conclusion, the JCIA would like to adopt visual and image analysis scales to evaluate the anti-wrinkle effects objectively. Generally, wrinkles are roughly classified into three groups as fine wrinkles, linear deep wrinkles and crow's feet. However, academic societies of dermatology or cosmetics have not yet established a definition of wrinkles in Japan. Thus, in advance of setting up an evaluation method, the definition of wrinkles f3r evaluation must be decided. Wrinkles are defined by the task force of the JCIA as follows; furrows that people can recognize visually and that appear on the forehead, the corners of the eyes and the backs of the neck with aging. In addition, furrows are emphasized by exposure to solar light and by dry conditions. Visual evaluation is the most sensitive method and can be applied to most types of wrinkles. However, visual evaluation is hard to express digitally as results. Besides, in the case of image analysis, comparisons of data obtained from distinct examinations can not be done, because data from image analysis are relative values. Thus, to enhance the reliability of the evaluations, the adoption of an objective scale was required. The principle of the evaluation method is to analyze images taken from silicone replicas of wrinkle areas using several parameters, such as the proportion of the wrinkle $area({\%})$, the mean depth of the wrinkles (mm), the mean depth of the deepest wrinkle (m) and the deepest point on the deepest wrinkle. Lights are shown on the skin replica from an orthogonal direction of the main orientation of the wrinkle, and the resulting shadow images are quantified by the image analysis method. To increase the precision of the data or to allow comparisons of independent examinations, a scale with furrows of several depths, 200, 400, 600, 800, and $1000{\mu}m$, is adapted in the evaluation system. I will explain the guidelines established by the JCIA in the presentation.

Extraction of Renal Glomeruli Region using Genetic Algorithm (유전적 알고리듬을 이용한 신장 사구체 영역의 추출)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.30-39
    • /
    • 2009
  • Extraction of glomeruli region plays a very important role for diagnosing nephritis automatically. However, it is not easy to extract glomeruli region correctly because the difference between glomeruli region and other region is not obvious, simultaneously unevennesses that is brought in the sampling process and in the imaging process. In this study, a new method for extracting renal glomeruli region using genetic algorithm is proposed. The first, low and high resolution images are obtained by using Laplacian-Gaussian filter with ${\sigma}=2.1$ and ${\sigma}=1.8$, then, binary images by setting the threshold value to zero are obtained. And then border edge is detected from low resolution images, the border of glomeruli is expressed by a closed B-splines' curve line. The parameters that decide the closed curve line with this low resolution image prevent the noises and the border lines from breaking off in the middle by searching using genetic algorithm. Next, in order to obtain more precise border edges of glomeruli, the number of node points is increased and corrected in order from eight to sixteen and thirty two from high resolution images. Finally, the validity of this proposed method is shown to be effective by applying to the real images.

Video Streaming Receiver with Token Bucket Automatic Parameter Setting Scheme by Video Information File needing Successful Acknowledge Character (성공적인 확인응답이 필요한 비디오 정보 파일에 의한 토큰버킷 자동 파라메타 설정 기법을 가진 비디오 스트리밍 수신기)

  • Lee, Hyun-no;Kim, Dong-hoi;Nam, Boo-hee;Park, Seung-young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.10
    • /
    • pp.1976-1985
    • /
    • 2015
  • The amount of packets in palyout buffer of video streaming receiver can be changed by network condition, and saturated and exhausted by the delay and jitter. Especially, if the amount of incoming video traffic exceeds the maximum allowed playout buffer, buffer overflow problem can be generated. It makes the deterioration of video image and the discontinuity of playout by skip phenomenon. Also, if the incoming packets are delayed by network confusion, the stop phenomenon of video image is made by buffering due to buffer underflow problem. To solve these problems, this paper proposes the video streaming receiver with token bucket scheme which automatically establishes the important parameters like token generation rate r and bucket maximum capacity c adapting to the pattern of video packets. The simulation results using network simulator-2 (NS-2) and joint scalable video model (JSVM) show that the proposed token bucket scheme with automatic establishment parameter provides better performance than the existing token bucket scheme with manual establishment parameter in terms of the generation number of overflow and underflow, packer loss rate, and peak signal to noise ratio (PSNR) in three test video sequences.

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

A Study on the Automatic Generation of Test Case Based on Source Code for Quality Improvement (소프트웨어 품질향상을 위한 소스코드 기반의 테스트 케이스 자동 생성에 관한 연구)

  • Son, Ung-Jin;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.186-192
    • /
    • 2015
  • This paper proposes an automatic generation technology of test case based on API in source code for software's quality improvement. The proposed technology is comprised of four processes which are analyzing source code by using the Doxygen open source tool, defining API specification by using analyzed results, creating test design, generating a test case by adapting Pairwise test technology. Analyzing source code by using the Doxygen open source tool is the phase in which API information in source code such as the API name, input parameter and return parameter are extracted. Defined API specification by using analyzed results is the phase where API informations, which is needed to generate test case, are defined as a form of database by SQLite database on the basis of extracted API information. Creating test design is the phase in which the scenario is designed in order to be composed as database by defining threshold of input and return parameters and setting limitations based on the defined API. Generating a test case by adapting Pairwise test technique is the phase where real test cases are created and changed into database by adapting Pairwise technique on the base of test design information. To evaluate the efficiency of proposed technology, the research was conducted by begin compared to specification based test case creation. The result shows wider test coverage which means the more cases were created in the similar duration of time. The reduction of manpower and time for developing products is expected by changing the process of quality improving in software developing from man-powered handwork system into automatic test case generation based on API of source code.