• Title/Summary/Keyword: Setting parameters

Search Result 506, Processing Time 0.03 seconds

Feasibility study of the beating cancellation during the satellite vibration test

  • Bettacchioli, Alain
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.2
    • /
    • pp.225-237
    • /
    • 2018
  • The difficulties of satellite vibration testing are due to the commonly expressed qualification requirements being incompatible with the limited performance of the entire controlled system (satellite + interface + shaker + controller). Two features cause the problem: firstly, the main satellite modes (i.e., the first structural mode and the high and low tank modes) are very weakly damped; secondly, the controller is just too basic to achieve the expected performance in such cases. The combination of these two issues results in oscillations around the notching levels and high amplitude beating immediately after the mode. The beating overshoots are a major risk source because they can result in the test being aborted if the qualification upper limit is exceeded. Although the abort is, in itself, a safety measure protecting the tested satellite, it increases the risk of structural fatigue, firstly because the abort threshold has been already reached, and secondly, because the test must restart at the same close-resonance frequency and remain there until the qualification level is reached and the sweep frequency can continue. The beat minimum relates only to small successive frequency ranges in which the qualification level is not reached. Although they are less problematic because they do not cause an inadvertent test shutdown, such situations inevitably result in waiver requests from the client. A controlled-system analysis indicates an operating principle that cannot provide sufficient stability: the drive calculation (which controls the process) simply multiplies the frequency reference (usually called cola) and a function of the following setpoint, the ratio between the amplitude already reached and the previous setpoint, and the compression factor. This function value changes at each cola interval, but it never takes into account the sensor signal phase. Because of these limitations, we firstly examined whether it was possible to empirically determine, using a series of tests with a very simple dummy, a controller setting process that significantly improves the results. As the attempt failed, we have performed simulations seeking an optimum adjustment by finding the Least Mean Square of the difference between the reference and response signal. The simulations showed a significant improvement during the notch beat and a small reduction in the beat amplitude. However, the small improvement in this process was not useful because it highlighted the need to change the reference at each cola interval, sometimes with instructions almost twice the qualification level. Another uncertainty regarding the consequences of such an approach involves the impact of differences between the estimated model (used in the simulation) and the actual system. As limitations in the current controller were identified in different approaches, we considered the feasibility of a new controller that takes into account an estimated single-input multi-output (SIMO) model. Its parameters were estimated from a very low-level throughput. Against this backdrop, we analyzed the feasibility of an LQG control in cancelling beating, and this article highlights the relevance of such an approach.

Estimation of Travel Time in Natural River and Dam Outflow Conditions Considering Rainfall Conditions and Soil Moisture Accounting (강우조건과 토양함수상태를 고려한 자연하천과 댐 방류량 조건에서의 도달시간 산정)

  • Kim, Dong Phil;Kim, Kyoung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.537-545
    • /
    • 2018
  • Determination of the time parameters such as the travel time in the design flood is very important. The travel time is mainly used for flood and river management, and the travel time of non flood season is used for maintenance flow and management of the river. Estimation of travel time for natural rivers is mainly based on the geomorphological factors of the basin. In addition to the topographical factors, the travel time is calculated by considering the factors of the runoff curve, velocity and rainfall intensity. However, there is no study on the estimation of travel time considering both the rainfall condition and the soil moisture accounting by the frequency period. Therefore, the travel time calculation is divided into the case of setting the Hwanggang Dam and the Imjin bridge water level station of Imjin river as the natural river considering rainfall condition by the frequency period and the soil moisture accounting, and the case of traveling the Imjin bridge water level station according to the condition of outflow of the Hwanggang Dam. For the sections set as natural rivers, the results were verified by comparing with the newly developed travel time calculation method. Based on the results, the travel times of the Hwanggang Dam outflow conditions were calculated. The time to travel in this study can be secured flood control of the Imjin river basin and time to prepare for danger when outflowing the the Hwanggang Dam.

Performance Evaluation for the A/O Pure-Oxygen Biofilm (POB) Process on the Removal of Organics and TKN in the Industrial Wastewater (혐기/호기 순산소 생물막공법에 의한 산업폐수의 유기물 및 TKN 제거 성능평가)

  • Jang, Am;Kim, Hong Suck;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.837-847
    • /
    • 2000
  • For the treatment of wastewaters generated from beer industry and petrochemical company with high organic and nitrogen contents, laboratory scale of A/O Pure-Oxygen Biofilm (POB) process was developed and studied by means of the comparative economic analysis with extended aeration process. When the wastewater of beer company was initially treated by the A/O POB process in the ranges of 70 to 150 mg TOC/L diluted with tap water, higher than 92% of TOC removal was accomplished in the all ranges. In case of petrochemical wastewater, the initial TOC removal was as low as 52%, though, it increased to 86% after 32 days of operation and also the TKN removal marked 71% after 27 days. Continuous high removal rates were monitored in both the TOC and TKN parameters during the experimental period. Due to the cost for PSA (Pressure Swing Adsorption) setting and biomass supporting media installation, the initial construction cost of A/O POB process was 2.9 times higher than that of extended aeration process. However, the advantages such as low sludge production, no need for sludge recycling and low energy consumption allow the A/O POB process to have 2.5 times lower operation and maintenance costs. Consequently, in the long term of operation, it is likely that A/O POB process would show higher performance as well as cost effectiveness compared to extended aeration process.

  • PDF

Analysis of the Thermal Environment in the Laying House (산란계사내부 열환경 분석)

  • Kim Y. B.;Lee S. K.;Kim S. T.;La W. J.;Chang H. H.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.177-188
    • /
    • 2005
  • In this study, the thermal environmental factors in a layer f(arm such as dry bulb temperature, relative humidity, black globe temperature and illumination intensity were measured and analyzed to serve as basis for effective design and plan of poultry houses. The correlation analysis between the different factors was also done. Heat Index as measure of the thermal stress was also calculated and analyzed. A $1,000m^2$ laying house, 4 meters high with 52,000 layers in six-stage type cages was used in the measurement of the different environmental parameters. The results were as follows; 1. The temperature of the inside air and materials was directly related to the increase in aerial temperature based on the dry-bulb, black globe temperature reading. The correlation factor of the outside to inside air based on dry bulb setting was very significant at 0.927 The dry bulb temperature for inside temperature ranged from $19.9\~28.8^{\circ}C\;with\;SD+2.2^{\circ}C$ while that of the outside air was $16.2\~33.1^{\circ}C,\;SD+3.5^{\circ}C$. In addition, the temperature of the inside air was very stable. 2. The black globe temperature of the inside air ranged from $20.1\~28.8^{\circ}C,\;SD+2.3^{\circ}C$ while that of the outside air was $16.2\~47.5^{\circ}C,\;SD+6.0^{\circ}C$. 3. The relative humidity of the outside and inside air was $72.4\~100\;and\;50.2\~85.6\%$ with an average of $89.2\;and\;71.7\%$, respectively. 4. The illumination intensity in the laying house was less than 7 lux, with an average of $1.2\~2.5lux$ relative to height indicating that the laying house was well isolated from outside radiation. 5. The heat index of the inside air of the laying house had a high variation from $20.5^{\circ}C,\;SD+2.5^{\circ}C$ while that of the outside air was $13.1\~45.5^{\circ}C$, with an average of $21.6^{\circ}C,\;SD+6.3^{\circ}C$.

  • PDF

Development of Stochastic Decision Model for Estimation of Optimal In-depth Inspection Period of Harbor Structures (항만 구조물의 최적 정밀점검 시기 추정을 위한 추계학적 결정모형의 개발)

  • Lee, Cheol-Eung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.63-72
    • /
    • 2016
  • An expected-discounted cost model based on RRP(Renewal Reward Process), referred to as a stochastic decision model, has been developed to estimate the optimal period of in-depth inspection which is one of critical issues in the life-cycle maintenance management of harbor structures such as rubble-mound breakwaters. A mathematical model, which is a function of the probability distribution of the service-life, has been formulated by simultaneously adopting PIM(Periodic Inspection and Maintenance) and CBIM(Condition-Based Inspection and Maintenance) policies so as to resolve limitations of other models, also all the costs in the model associated with monitoring and repair have been discounted with time. From both an analytical solution derived in this paper under the condition in which a failure rate function is a constant and the sensitivity analyses for the variety of different distribution functions and conditions, it has been confirmed that the present solution is more versatile than the existing solution suggested in a very simplified setting. Additionally, even in that case which the probability distribution of the service-life is estimated through the stochastic process, the present model is of course also well suited to interpret the nonlinearity of deterioration process. In particular, a MCS(Monte-Carlo Simulation)-based sample path method has been used to evaluate the parameters of a damage intensity function in stochastic process. Finally, the present stochastic decision model can satisfactorily be applied to armor units of rubble mound breakwaters. The optimal periods of in-depth inspection of rubble-mound breakwaters can be determined by minimizing the expected total cost rate with respect to the behavioral feature of damage process, the level of serviceability limit, and the consequence of that structure.

Immune Function-enhancing Effects of Bojungikkitanggami-bang (보중익기탕가미방의 면역기능 증진 효과)

  • Lee Sang Hun;Lee Seung Eon;Lee Si Hyeong;Shin Jo Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.528-533
    • /
    • 2004
  • The immune system acts to protect the host from infectious agents that exist in the environment and from other noxious insults. The immune system has two functional divisions: the innate and the acquired. Both components involve various factors such as cytokines. A number of methodologies exist to assess aspects of immune function. There are large inter-individual variations in many immune functions even among the healthy. Genetics, age, gender, smoking habits, habitual levels of exercise, alcohol consumption, diet, stage in the female menstrual cycle, stress, history of infections and vaccinations, and early life experiences are likely to be important contributors to the observed variation. While it is clear that individuals with immune responses significantly below 'normal' are more susceptible to infectious agents and exhibit increased infectious morbidity and mortality, it is not clear how the variation in immune function among healthy individuals relates to variation in susceptibility to infection. Oriental medicine is an important factor contributing to immune competence. The author investigated the immune enhancement effects of Bojungikkitanggami-bang (BITB). The forced swimming test (FST) has been used as a screening model for new immune enhancement agents. In the present study, the author investigated the effects of BITB on FST and blood biochemical parameters related to fatigue, glucose (Glc); blood urea nitrogen (BUN); lactate dehydrogenase (LDH); creatinine; and total protein (TP). The author found that BITB (1 g/kg) significantly reduced the immobility time in the FST compared to the control. In addition, the contents of Glc, LDH, BUN, TP in the blood serum were increased in BITB (1g/kg)-fed group. Also, the author investigated the effects of BITB on the production of cytokines in human T-cell line, MOLT-4 cells. BITB (1 mg/ml) significantly increased the interferon (IFN)-vproduction compared with media control (about 2.2-fold for IFN-γ) at 24 h. However, BITB has not affect the production of IL-2 and IL-4. In addition, BITB increased the protein expression level of IFN-γ in MOLT-4 cells. Thus, BITB may have therapeutic value in generating or enhancing immune function in a clinical setting.

A study on the characteristics of tunnel deformation and support system according to tunnel portal reinforcement method (터널 갱구부 보강방법에 따른 터널 변형 및 지보재 응력특성에 관한 연구)

  • Moon, Kyoung-Sun;Seo, Yoon-Sic;Kang, Si-On;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.625-639
    • /
    • 2018
  • This study is about the reinforcing type of reinforcement method which is reinforced in tunnel portal of tunnel with bad ground condition. Generally, it is known that the horizontal reinforcement method is more effective than the conventional reinforcement method. However, as a limitation of the tunnel construction technology, it is being constructed by the superposition reinforcement method. In recent years, high-strength large-diameter steel pipes and horizontally oriented longitudes (L = 30.0~50.0 m) construction technology have been developed. Therefore, it is required to study reinforcement method of tunnel portal reinforcement method. Therefore, 3-D numerical analysis (Midas GTS NX 3D) was performed by setting the reinforcement method (No reinforcement type, overlap reinforcement type and horizontal reinforcement type) and ground condition as parameters. As a result, it was considered that the reinforcement effect was the largest as the horizontal reinforcement type of the reinforcement method was the smallest in the displacement and the support material stress. Based on the results of the numerical analysis, horizontal steel pipe grouting was applied to the actual tunnel site. The displacement of the tunnel portal and the stress of the support material occurred within the allowable values and were considered to ensure sufficient stability.

Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources (국악음원의 방사특성을 고려한 국악원의 음향 성능 예측)

  • 정철호;이정권;연철호;한찬훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.146-161
    • /
    • 2004
  • There have been always some difficulties in target setting and conditioning of acoustic performances of the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. In this study, the radiation characteristics of four typical Korean traditional musical sources were investigated in precision and their usage was demonstrated: The selected musical sources were Gayageum (string), Daegeum (woodwind), Jango (drum), and Pansori Chang (vocal performance). Each sound source was located at the center of a semi-anechoic chamber and the directivity was determined by the measured sound pressure levels in every 10° angular position, for both vertical and horizontal directions. The directivity pattern of Gayageum varies from a uniform to a complex pattern having many side lobes with the increase of frequency. The main radiation of Daegeum is toward the upward direction. The directivity pattern of Jango is clearly a side-oriented one and the left direction intensity is sharper than its right side at low frequencies. For the Chang, the directivity pattern change from a uniform pattern to a frontally directed one as the frequency goes high. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures for the Busan National Korean Traditional Music Hall which is under construction. Parameters such as RT, SPL, C80, IE, STI were calculated at two receiver positions by using a ray tracing technique. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

Image Analysis of Computer Aided Diagnosis using Gray Level Co-occurrence Matrix in the Ultrasonography for Benign Prostate Hyperplasia (전립선비대증 초음파 영상에서 GLCM을 이용한 컴퓨터보조진단의 영상분석)

  • Cho, Jin-Young;Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin;Ye, Soo-Young
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.184-191
    • /
    • 2015
  • Prostate ultrasound is used to diagnose prostate cancer, BPH, prostatitis and biopsy of prostate cancer to determine the size of prostate. BPH is one of the common disease in elderly men. Prostate is divided into 4 blocks, peripheral zone, central zone, transition zone, anterior fibromuscular stroma. BPH is histologically transition zone urethra accompanying excessive nodular hyperplasia causes a lower urinary tract symptoms(LUTS) caused by urethral closure as causing the hyperplastic nodule characterized finding progressive ambient. Therefore, in this study normal transition zone image for hyperplasia prostate and normal transition zone image is analyzed quantitatively using a computer algorithm. We applied texture features of GLCM to set normal tissue 60 cases and BPH tissue 60cases setting analysis area $50{\times}50pixels$ which was analyzed by comparing the six parameters for each partial image. Consequently, Disease recognition detection efficiency of Autocorrelation, Cluster prominence, entropy, Sum average, parameter were high as 92~98%.This could be confirmed by quantitative image analysis to nodular hyperplasia change transition zone of the prostate. This is expected secondary means to diagnose BPH and the data base will be considered in various prostate examination.

A Study on the Multi-Carrier System for Throughput Enhancement in Underwater Channel Environments (수중 채널 환경에서 전송량 증대를 위한 다중반송파 시스템에 관한 연구)

  • Kim, Min-sang;Cho, Dae-young;Ko, Hak-lim;Hong, Dae-Ki;Kim, Seung-geun;Im, Tae-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1193-1199
    • /
    • 2015
  • Studies applying multiple carrier method such as OFDM(Orthogonal Frequency Division Multiplexing) or FMT(Filtered Multi-Tone) to Underwater acoustic communication(UAC) system are actively under way as UAC is utilized in the various fields and the demand of high speed data transmission increases. In the existing OFDM method, the use of virtual carrier, which is inserted not to affect the adjacent channel in the frequency domain, and the cyclic prefix, which is used to reduce the impact of Inter Symbol Interference and Inter Channel Interference, decrease the throughput. In particular, the length of cyclic prefix to be used becomes longer under water since underwater has a rapidly changing channel characteristic, and the data throughput diminishes because it has to allocate more subcarrier on virtual carrier. This study therefore suggests FMT-OFDM system, a combination of OFDM and FMT, for the purpose of enhanced throughput in the underwater channel environment. Besides, in this study, channel is modeled based on data measured in real sea and the performance is analyzed after setting system parameters.