• Title/Summary/Keyword: Setting parameters

Search Result 510, Processing Time 0.053 seconds

Modeling Framework for Continuous Dynamic Systems Using Machine Learning of Hypothetical Model (가설적 모델의 기계학습을 이용한 연속시간 동적시스템 모델링 프레임워크)

  • Hae Sang Song;Tag Gon Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.32 no.1
    • /
    • pp.13-21
    • /
    • 2023
  • This paper proposes a method of automatically generating a model through a machine learning technique by setting a hypothetical model in the form of a gray box or black box with unknown parameters, when the big data of the actual system is given. We implements the proposed framework and conducts experiments to find an appropriate model among various hypothesis models and compares the cost and fitness of them. As a result we find that the proposed framework works well with continuous systems that could be modeled with ordinary differential equation. This technique is expected to be used well for the purpose of automatically updating the consistency of the digital twin model or predicting the output for new inputs using recently generated big data.

Using Mean Shift Algorithm and Self-adaptive Canny Algorithm for I mprovement of Edge Detection (경계선 검출의 향상을 위한 Mean Shift 알고리즘과 자기 적응적 Canny 알고리즘의 활용)

  • Shin, Seong-Yoon;Pyo, Seong-Bae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.7
    • /
    • pp.33-40
    • /
    • 2009
  • Edge detection is very significant in low level image processing. However, majority edge detection methods are not only effective enough cause of the noise points' influence, even not flexible enough to different input images. In order to sort these problems, in this paper an algorithm is presented that has an extra noise reduction stage at first, and then automatically selects the both thresholds depending on gradient amplitude histogram and intra class minimum variance. Using this algorithm, can fade out almost all of the sensitive noise points, and calculate the propose thresholds for different images without setting up the practical parameters artificially, and then choose edge pixels by fuzzy algorithm. In finally, get the better result than the former Canny algorithm.

Applying the ANFIS to the Analysis of Rain and Dark Effects on the Saturation Headways at Signalized Intersections (강우 및 밝기에 따른 신호교차로 포화차두시간 분석에의 적응 뉴로-퍼지 적용)

  • Kim, Kyung Whan;Chung, Jae Whan;Kim, Daehyon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4D
    • /
    • pp.573-580
    • /
    • 2006
  • The Saturation headway is a major parameter in estimating the intersection capacity and setting the signal timing. But Existing algorithms are still far from being robust in dealing with factors related to the variation of saturation headways at signalized intersections. So this study apply the fuzzy inference system using ANFIS. The ANFIS provides a method for the fuzzy modeling procedure to learn information about a data set, in order to compute the membership function parameters that best allow the associated fuzzy inference system to track the given input/output data. The climate conditions and the degree of brightness were chosen as the input variables when the rate of heavy vehicles is 10-25 %. These factors have the uncertain nature in quantification, which is the reason why these are chosen as the fuzzy variables. A neuro-fuzzy inference model to estimate saturation headways at signalized intersections was constructed in this study. Evaluating the model using the statistics of $R^2$, MAE and MSE, it was shown that the explainability of the model was very high, the values of the statistics being 0.993, 0.0289, 0.0173 respectively.

Morphological and Textural Characteristics of the Beach-dune System in South Korea, with the Possibility of a Dune Type Scheme Based on Grain-size Trend (국내 해안의 해빈-해안사구 지형 및 퇴적물 특성과 입도기반 사구유형 분석)

  • Rhew, Hosahng;Kang, Jihyun
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.3
    • /
    • pp.53-73
    • /
    • 2020
  • Morphology and grain size distribution of coastal dunes should be well documented because they are critical to dune's buffering capacity and resilience against storm surges. The nationwide coastal dune survey produced the dataset, including beach-dune topographic profiles and grain size parameters for frontal beaches, foredunes, and inland dunes. This research investigated the dataset to describe geomorphic and textural properties of coastal dunes: foredune slopes, dune heights above approximately highest high water, mean size, and sorting, together with associated variables of coastal setting that influence coastal dunes. It also explores the possibility of a dune type scheme based on gran size trends. The results are as follows. First, the coast in which dunes are developed is the primary control on foredune morphology and sediment texture. Coastal dunes on the east coast were developed more alongshore rather than inland, with gentler slopes on the higher ground and out of coarser sand. The shore aspect contributes to this pattern because the east coast cannot benefit from prevailing northwesterly. Second, grain size trends from beaches through foredunes to inland dunes were little identified. Third, 12 dune types were identified from 69 dunes, showing the indicative capability for the status of beaches and dunes. We confirmed that the dataset could increase our understanding of the overall characteristics of coastal dune morphology and texture, though there is something to be improved, for example, establishing the refined and comprehensive field survey protocol.

Security Analysis on TiGER KEM in KpqC Round 1 Competition Using Meet-LWE Attack (KpqC 1 라운드 TiGER KEM의 Meet-LWE 공격에 대한 안전성 분석)

  • Joohee Lee;Eun-min Lee;Jiseung Kim
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.5
    • /
    • pp.709-719
    • /
    • 2023
  • Recently, Post-Quantum Cryptography (PQC), which is secure against attacks using quantum computers, has been actively studied. In 2022, the KpqC competition, a competition for domestic PQC standardization, was launched, and a total of 16 candidate algorithms were received, and the first round is underway. In this paper, we apply Alexander May's Meet-LWE attack to TiGER, a lattice-based key encapsulation mechanism that is a candidate for the first round of the KpqC competition, and analyze its concrete attack complexity. The computational results of applying the Meet-LWE attack to each of the proposed parameters of TiGER show that the proposed TiGER192 parameter, which targets 192-bit quantum security, actually achieves 170-bit classical security. In addition, we propose a parameter setting to increase the attack complexity against the Meet-LWE attack.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

Genotoxic Effects on Gas Station Attendants in South-southeastern México due to Prolonged and Chronic Exposure to Gasoline

  • Rebeca I. Martinez-Salinas;Irene Sanchez-Moreno;Juan J. Morales Lopez;Benito Salvatierra Izaba;Everardo Barba Macias;Anahi Armas-Tizapantzi;Arturo Torres-Dosal
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.236-241
    • /
    • 2024
  • Background: Gasoline, a complex mixture of volatile organic compounds is classified as possibly carcinogenic to humans. Gasoline station attendants, consistently exposed to its hazardous components, may face genotoxic effects. This study aimed to assess the influence of varying work shift durations on DNA damage in gasoline station attendants. Methods: Ninety individuals from three locations in southern México were studied. Peripheral blood mononuclear cells (PBMCs) were isolated, and DNA damage was assessed using the comet assay. Demographic, occupational, and lifestyle data were collected. Statistical analyses included t-tests, ANOVA, and Pearson correlation. Results: Significant differences in DNA damage parameters were observed between exposed and unexposed groups. The impact of tobacco, alcohol, and exercise on DNA damage was negligible. Extended work shifts (12 and 24 hours) showed heightened DNA damage compared to 8-hour shifts and the unexposed group. A novel finding revealed a modest but significant correlation between DNA damage and job seniority. Conclusion: The study highlights the intricate relationship between occupational exposure to gasoline components, DNA damage, and work shift lengths. Extended shifts correlate with heightened genotoxic effects, emphasizing the importance of personalized safety measures. The significant correlation between DNA damage and job seniority introduces occupational longevity as a determinant in the genetic health of gasoline station attendants. This discovery has implications for implementing targeted interventions and preventive strategies to safeguard workers' genetic integrity throughout their years of service. The study calls for further exploration of unconsidered factors in understanding the multifactorial nature of DNA damage in this occupational setting.

Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

  • Soonil Kwon;Eue-Keun Choi;So-Ryoung Lee;Seil Oh;Hee-Seok Song;Young-Shin Lee;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • v.54 no.3
    • /
    • pp.140-153
    • /
    • 2024
  • Background and Objectives: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. Methods: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. Results: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). Conclusions: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise.

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory (자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가)

  • Jeong, Jee Yeon;Park, Seunghyun;Yi, GwangYong;Lee, Naroo;You, Ki Ho;Park, Junsun;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF