• Title/Summary/Keyword: Setting Depth

Search Result 315, Processing Time 0.027 seconds

A Effect of Cutting Resistance by Setting Angle According to the Cutting Condition in Turning (선삭에서 절삭조건에 따라 설치각이 절삭저항에 미치는 영향)

  • 신근하
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.88-95
    • /
    • 1997
  • This study provides the useful actual data instead of the experience data using in industrial fields. Especially, values of each components of cutting force are effective in the rake angle, setting angle and cutting area. Many researches have been made on the work piece materials, kinds of bite materials, rake angle, nose radius and depth of cut, but a few on the bite setting angle. In order to select optimal cutting speed, it was summarized the following results are achieved; A chieved that an affect of cutting resistance on the setting angle is a little under giving experimental conditions and therefore a worker can be choose the value of it randomly.

  • PDF

A Effect of Cutting Resistance by Setting Angle According to the Cutting Condition in Turning (선삭에서 절삭조건에 따라 설치각이 절삭저항에 미치는 영향)

  • 신근하
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 1997
  • This study provides the useful actual data instead of the experience data using in industrial fields. Especially, values of each components of cutting force are effective in the rake angle, setting angle and cutting area. Many researches have been made on the work piece materials, kinds of bite materials, rake angle, nose radius and depth of cut, but a few on the bite setting angle. In order to select optimal cutting speed, it was summarized the following results are achieved; A chieved that an affect of cutting resistance on the setting angle is a little under giving experimental conditions and therefore a worker can be choose the value of it randomly.

  • PDF

Durability of High-Fluidity Polymer-Modified Mortar (고유동 폴리머 시멘트 모르타르의 내구성)

  • Yoon Do Yong;Lee Youn Su;Joo Myung Ki;Jung In Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.691-694
    • /
    • 2004
  • The effects of polymer-cement ratio and antifoamer content on the setting time and durability of high-fluidity polymer-modified mortars using redispersible polymer powder are examined. As a result, the setting time of the polymer-modified mortars using redispersible polymer powder tend to delayed with increasing polymer-cement ratio, regardless of the antifoamer content. The water absorption and chloride ion penetration depth of the high-fluidity polymer-modified mortars using redispersible polymer powder decrease with increasing polymer-cement ratio and antifoamer content. The water absorption and chloride ion penetration improvement is attributed to the improved bond between cement hydrates and aggregates because of the incorporation of redispersible polymer powder.

  • PDF

An Experimental Study on the Properties of Concrete using High Volume of Coal Ash

  • Kim, Moo Han;Choi, Se Jin
    • Architectural research
    • /
    • v.4 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, the coal-ash production has been increased by increase of consumption of electric power. So it is important to secure a reclaimed land from pollution and develop practical application of coal ash. This is an experimental study to compare and analyze the properties of concrete using high volume of coal ash (including fly ash and bottom ash) as a part of fine aggregate. For this purpose, the mix proportions of concrete according to replacement ratio of coal ash (10, 20, 35, 50%) were selected. And then air content, slump, setting time, bleeding content, chloride content, compressive strength and carbonation test were performed. According to test results, it was found that the bleeding content of concrete using the coal ash decreased according to increase of replacement ratio. And the chloride content of concrete using the bottom ash as a part of fine aggregate increased as the replacement ratio of bottom ash increased, but it is satisfied with the total chloride content of concrete recommended by KCI - $0.3kg/m^3$ below. Also, the compressive strength of concrete using the bottom ash was similar to that of plain concrete(BA 0) after 28days of curing and the carbonation depth of concrete increased as the replacement ratio increased. However, the carbonation depth of concrete using the fly ash decreased as the replacement ratio of fly ash increased.

A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy (압전방식초음파치석제거기의작업조건에따른치과주조용합금의삭제결손부 양상에 관한 고찰)

  • Kim, Young-Sung;Kim, Soo-Hwan;Kim, Won-Kyung;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.385-390
    • /
    • 2009
  • Purpose: In this study we evaluated the morphologic aspects of defects created by a piezoelectric ultrasonic scaler with scaler tip on casting gold alloy using scanning electron microscope (SEM) images and defect surface profiles. Methods: 54 blocks of type III casting gold alloy (Firmilay, Jellenko Inc, CA, USA) were scaled by a piezoelectric ultrasonic scaler (P-MAX, Satelec, France) with scaler tip (No. 1 tip) on a sledge device. 2-dimensional profiles of defects on all samples were investigated by a surface profilometer (a-Step 500, KLA-Tencor, CA, USA). The selected working parameters were lateral force (0.5 N, 1.0 N, 2.0 N), mode (P mode, S mode), and power setting (2, 4, 8). SEM images were obtained. Defect surface profiles were made on Microsoft Excel program using data obtained by a surface profilometer. Results: Among P mode samples, there were similarities on defect surface profiles and SEM images regardless of lateral force. The defects created in P mode were narrow and shallow although the depth and the width increased as power setting changed low (2) to high (8). In P mode samples, the defect depth was the greatest when lateral force of 0.5 N was applied. However all the depths were smaller than 1 m. SEM images of Lateral force of 0.5 N, S mode, power setting 2 and 4 were similar to that of P mode, but the other SEM images of S mode showed discernible changes. Defect depth of S mode samples was the greatest when lateral force of 1.0 N was applied. Conclusions: Within the limitations of this study, it can be concoluded that removing capability of piezoelectric scaler with scaler tip becomes maximized as power level becomes higher but the capability is restricted when excessive lateral force is applied on scaler tip.

Visual Fatigue Reduction Based on Depth Adjustment for DIBR System

  • Liu, Ran;Tan, Yingchun;Tian, Fengchun;Xie, Hui;Tai, Guoqin;Tan, Weimin;Liu, Junling;Xu, Xiaoyan;Kadri, Chaibou;Abakah, Naana
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.4
    • /
    • pp.1171-1187
    • /
    • 2012
  • A depth adjustment method for visual fatigue reduction for depth-image-based rendering (DIBR) system is proposed. One important aspect of the method is that no calibration parameters are needed for adjustment. By analyzing 3D image warping, the perceived depth is expressed as a function of three adjustable parameters: virtual view number, scale factor and depth value of zero parallax setting (ZPS) plane. Adjusting these three parameters according to the proposed parameter modification algorithm when performing 3D image warping can effectively change the perceived depth of stereo pairs generated in DIBR system. As the depth adjustment is performed in simple 3D image warping equations, the proposed method is facilitative for hardware implementation. Experimental results show that the proposed depth adjustment method provides an improvement in visual comfort of stereo pairs as well as generating comfortable stereoscopic images with different perceived depths that people desire.

Influence of Depth Differences by Setting 3D Stereoscopic Convergence Point on Presence, Display Perception, and Negative Experiences (스테레오 영상의 깊이감에 따른 프레즌스, 지각된 특성, 부정적 경험의 차이)

  • Lee, SangWook;Chung, Donghun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.1
    • /
    • pp.44-55
    • /
    • 2014
  • The goal of 3D stereoscopy is not only to maximize positive experiences (such as sense of realism) by adding depth information to 2D video but to also minimize negative experiences (such as fatigue). This study examines the impact of different depth levels induced by adjusting 3D camera convergences on positive and negative experiences and finds an optimal parameter for viewers. The results show that there are significant differences among depth levels on spatial involvement, realistic immersion, presence, depth perception, screen transmission, materiality, shape perception, spatial extension and display perception. There are also significant differences for fatigue and unnaturalness. This study suggests that reducing the camera convergence angle of an object by $0.17^{\circ}$ behind the object is the optimal parameter in a 3D stereoscopic setting.

The Effect of Goal Setting Training on Actor's Feeling of Happiness:Single Case Study (목표설정 훈련이 배우의 행복감에 미치는 효과:단일사례연구)

  • Yoo, Hyun-Mee
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.3
    • /
    • pp.345-355
    • /
    • 2020
  • This study examines the effect of goal setting training during psychological skills training on improving the happiness of actors using a single case study design. The subject of this study was a famous actor in his late 40s who had received personal psychological training from this researcher, a sports psychological counselor, to strengthen his psychological capabilities. The goal setting training program consisted of 8 sessions of 60~90 minutes each. For the purpose of this study, pre and post tests were conducted using the Oxford Happiness Scale developed by Argyle (2005), and in-depth interviews were also conducted. As a result, goal setting training had a positive effect on improving the happiness of actors.

Form grinding characteristics of Sr ferrite (Sr 페라이트의 총형연삭특성)

  • 김성청;이재우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.21-27
    • /
    • 1997
  • This paper aims to clarify the effects of grinding conditions in form grinding of Sr-ferrite with the electro-plated diamond wheel. The main conclusions obtained were as follows. (1) The flexural strength and surface roughness of ferrite became the best at the peripheral wheel speed of 1700 m/min. (2) In the case of the depth of cut larger than 0.4mm, crack layers is induced in the ground surface, and the fracture type of chips exhibits slight ductile mode in the depth of cut smaller than 0.2mm. (3) Whe the depth of cut exceeds 0.6mm, the wheel life becomes extremely severe due to the large chipping and brack- age in the diamond grains. However, at the depth of cut .leq. 0.05mm, the diamond grain shows abrasive wear. (4) The decrease of flexural strength and the increase of surface roughness is in proportion to the increase of the feed rate. (5) Most effective nozzle setting angles with various delivery conditions of the grinding fluid, such as nozzle position .PHI. , flow rate Q, etc., were made clear.

  • PDF

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro (큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF