• Title/Summary/Keyword: Set up error

Search Result 330, Processing Time 0.027 seconds

The Impact of Stock-to-Flow Price Ratio on Housing Starts (재고-신규주택 상대가격이 주택공급에 미치는 영향)

  • Ji, Kyu Hyun;Choi, Sung Ho
    • Land and Housing Review
    • /
    • v.11 no.1
    • /
    • pp.59-66
    • /
    • 2020
  • This thesis investigates relationship between Stock-to-Flow price and housing starts in Seoul metropolitan form 2008 year to 2019 year. The paper tests the relationship through two time-series models such as a vector error correction model and Dynamic Panel regression model. The model results show evidence of positive correlation between Stock-to-Flow price and housing starts in the long run. By transforming the regional data into a panel data set and running a fixed effects model, we test the explanatory power of PBR on housing starts. The result of VECM confirms that one unit uprising PBR raises up apartment construction by 7.4%. This result supports that PBR is a major factor in choosing a start of housing construct. Base on the result of empirical model, We also suggest that the market self-regulation function of housing providers is operating in the entire metropolitan area market.

A Quality Comparison of English Translations of Korean Literature between Human Translation and Post-Editing

  • LEE, IL-JAE
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.165-171
    • /
    • 2018
  • As the artificial intelligence (AI) plays a crucial role in machine translation (MT) which has loomed large as a new translation paradigm, concerns have also arisen if MT can produce a quality product as human translation (HT) can. In fact, several MT experimental studies report cases in which the MT product called post-editing (PE) as equally as HT or often superior ([1],[2],[6]). As motivated from those studies on translation quality between HT and PE, this study set up an experimental situation in which Korean literature was translated into English, comparatively, by 3 translators and 3 post-editors. Afterwards, a group of 3 other Koreans checked for accuracy of HT and PE; a group of 3 English native speakers scored for fluency of HT and PE. The findings are (1) HT took the translation time, at least, twice longer than PE. (2) Both HT and PE produced similar error types, and Mistranslation and Omission were the major errors for accuracy and Grammar for fluency. (3) HT turned to be inferior to PE for both accuracy and fluency.

A Study on Deep Reinforcement Learning Framework for DME Pulse Design

  • Lee, Jungyeon;Kim, Euiho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2021
  • The Distance Measuring Equipment (DME) is a ground-based aircraft navigation system and is considered as an infrastructure that ensures resilient aircraft navigation capability during the event of a Global Navigation Satellite System (GNSS) outage. The main problem of DME as a GNSS back up is a poor positioning accuracy that often reaches over 100 m. In this paper, a novel approach of applying deep reinforcement learning to a DME pulse design is introduced to improve the DME distance measuring accuracy. This method is designed to develop multipath-resistant DME pulses that comply with current DME specifications. In the research, a Markov Decision Process (MDP) for DME pulse design is set using pulse shape requirements and a timing error. Based on the designed MDP, we created an Environment called PulseEnv, which allows the agent representing a DME pulse shape to explore continuous space using the Soft Actor Critical (SAC) reinforcement learning algorithm.

Broadband Instantaneous Frequency Measurement System Based on the Dual Paths of the Stimulated Brillouin Scattering Effect

  • Jiahong Zhang;Weijie Liao
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.378-386
    • /
    • 2023
  • A wideband instantaneous frequency measurement (IFM) system is been proposed, designed and analyzed. Phase modulation to intensity modulation conversion is implemented based on the stimulated Brillouin scattering (SBS) effect, and the microwave frequency can be measured by detecting the change in output power. Theoretical analysis shows that the frequency measurement range can be extended to 4fb by adjusting the two sweeping signals of the phase modulators with a difference of 2fb. The IFM system is set up using VPI transmission maker software and the performances are simulated and analyzed. The simulation results show that the measurement range is 0.5-45.96 GHz with a maximum measurement error of less than 9.9 MHz. The proposed IFM system has a wider measurement range than the existing SBS-based IFM system.

The Study for Establishment of Protocol with Quality Assurance (QA) of Hyperthermia Cancer Therapy System in Korea (국내 온열 암 치료 시스템의 품질관리 프로토콜 확립에 대한 연구)

  • Hwang, Jinho;Kay, Chul-Seung
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.1
    • /
    • pp.668-674
    • /
    • 2020
  • Quality Assurance (QA) is essential to provide effective hyperthermia, but in the case of a problem with a hyperthermia cancer therapy system in Korea, the manufacturers or venders are repairing and maintaining the system. In Korea, if an error occurs in the hyperthermia system, the manufacturer and sales agent are repairing and maintaining it. There is no QA protocol suitable for the domestic situation. This study is based on the QA guidelines recommended by institutions such as European Society for Hyperthermia Oncology (ESHO), Hellenic Society of Oncologic Hyperthermia (HSOH), and the results of questionnaires to hospitals that have hyperthermia cancer therapy systems in Korea. By developing an optimized QA protocol, we aim to reduce the errors and inaccuracies that can occur in during hyperthermia such as measurement of temperature, instrumentation, and heat transfer. In addition, we will visit a hospital with a hyperthermia cancer therapy system in Korea to perform a QA based on this study, and study to specify tolerances and accurate QA set-up parameters using the measured QA results.

Transient Voltage Measuring System Using the Capacitive Electric Field Sensor (용량성 전장센서를 이용한 과도전압측정계)

  • Lee, Bok-Hee;Kil, Gyung-Suk;Ju, Mun-No;Lee, Sung-Heon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.9-16
    • /
    • 1996
  • This paper deals with the capacitive voltage divider which can measure a transient voltages generated by operating a high voltage impulse generator. The transient voltage measuring system using the capacitive electric field sensor consists of the planar-type electric field sensor having a fast response characteristic and the wide-bandwidth voltage follower, and the input impedance of which is extremely high, about $10^{12}{\Omega}$. In order to analyze the response characteristics to a step input, the newly developed calibration method is proposed, and the error of voltage dividing ratio associated with set-up condition is investigated. Also the optimal set-up condition that is to be maintained within the range of 0.5 % is taken. From the calibration experiment, the frequency bandwidth of the transient voltage measuring system whose response time to a step input is about 15.8 ns, is from 6.37 Hz to 27.3 MHz. Therefore it is possible to measure the commercial frequency voltages as well as the transient over voltages without signal distortions.

  • PDF

The Application of a Microwave Sensor for Traffic Signal Control on Urban Arterial (도시간선도로상에서 교통신호제어를 위한 초단파 검지기(RTMS)의 적용성에 관한 연구)

  • 오영태;오영태
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.4
    • /
    • pp.133-151
    • /
    • 1995
  • The collective of highly reliable traffic data is necessary for traffic signal control. This study is to test application of RTMS sensor to traffic signal control. In order to find out the possibility of its application th traffic signal control, 5 types of experiments were performed. The major findings are as follows ; -The detection are a has been changing according to degree and gain. -At the results of experiments for interference are a measure, Degree 60 is stable condition. -At the results of reliability test for volume and speed. the error rate decreases as speed increases and that of Zone 1 is lower than that of Zone 3. -Two modes are set up for reliability test of traffic volume. It founds that the detection reliability of the stopped vehicles are higher than that of the passing vehicles at sidefire-intersection mode. It founds that the results are vice-versa at sidefire-highway mode. Conclusively, this sensor cannot directly apply to colection of traffic data for traffic signal control. However, this sensor can be substituted for a loop detector which is used popularly for signal control, and freeway traffic control if above faults are made up.

  • PDF

Discrete Multiwavelet-Based Video Watermarking Scheme Using SURF

  • Narkedamilly, Leelavathy;Evani, Venkateswara Prasad;Samayamantula, Srinivas Kumar
    • ETRI Journal
    • /
    • v.37 no.3
    • /
    • pp.595-605
    • /
    • 2015
  • This paper proposes a robust, imperceptible block-based digital video watermarking algorithm that makes use of the Speeded Up Robust Feature (SURF) technique. The SURF technique is used to extract the most important features of a video. A discrete multiwavelet transform (DMWT) domain in conjunction with a discrete cosine transform is used for embedding a watermark into feature blocks. The watermark used is a binary image. The proposed algorithm is further improved for robustness by an error-correction code to protect the watermark against bit errors. The same watermark is embedded temporally for every set of frames of an input video to improve the decoded watermark correlation. Extensive experimental results demonstrate that the proposed DMWT domain video watermarking using SURF features is robust against common image processing attacks, motion JPEG2000 compression, frame averaging, and frame swapping attacks. The quality of a watermarked video under the proposed algorithm is high, demonstrating the imperceptibility of an embedded watermark.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF