An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System (지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구)

  • Ahn, Byung-Chun;Kim, Jae-Wan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

A Study on the Segregation Reduction of Self-Leveling Color Mortar by Using Variable Composition Set of Plasticizer and Thickener (유동화제와 증점제의 조성비가 자기수평 칼라 모르타르의 재료분리저감에 미치는 영향에 관한 실험적 연구)

  • Chae, Woo-Byung;Seon, Yun-Suk;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.101-106
    • /
    • 2009
  • We study on the segregation reduction effect of Self-Leveling Color Mortar by using variable composition set of plasticizer and thickener, Naphthalene, melamine and polycarbonate-based dispersants were employed as plasticizers for examining on fluidity of mortar mixtures. For enhancement of mortar stability without loss of it's fluidity, two types of thickener were used such as polysaccharide(PS) and hydroxyethylcellulose(HEC). As a result, the most effective mortar was composed by feeding 0.519% of polycarbonate-based dispersant with 0.002587% of PS and 0.155844% of HEC on amount of basic mortar.

  • PDF

Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정값 비교)

  • Lee, Snag-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

A Study on the Current Status and the Problem of Classification System in Agricultural Facilities (농업건축물 분류체계 현황 및 문제점 파악에 관한 연구)

  • Choi, Oh-Young;Kim, Tae-Hui;Kim, Jae-Yeob;Kim, Gwang-Hee;Cho, Hyung-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.253-257
    • /
    • 2009
  • General technique and management technology of agriculture have development in every year to ensure the competitiveness of agriculture. Accordingly, Interested in using information systems management technology is improving. For information system, the first system of rural buildings category should be established. Classification system is set up through each specific code. and it takes advantage of the information system is to achieve the computerization of agricultural society. Therefore, in this study construction information classification system, quantity of output category, got to the standard classification system architecture, apply to agricultural buildings to review the situation and saw a problem. The result, it is the complexity and broad scope, and it is set to inappropriate setting of the Category item.

  • PDF

Analysis of the Possibility of Using the Durometer A Type when Estimating the Specific Setting Time Using CGS for Fine Aggregate (CGS를 잔골재로 활용하는 콘크리트의 응결시간 추정시 고무경도계 A타입 사용 가능성 분석)

  • Lee, Hyuk-Ju;Han, Jun-Hui;Baek, Seung-Bok;Shin, Yong-Sub;Han, Min-Choel;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.116-117
    • /
    • 2019
  • In this research, Proctor insertion resistance test values and Durometer A type hardness values were compared and analyzed between the setting times of the concrete using CGS for Fine Aggregate, and the results are summarized as follows. 1) The Proctor penetration resistance test value and the hardness value of Durometer A type showed a high correlation in the form of a curve. 2) About surface finish The resolution exceeding the hardness value of the Durometer A type uses about 25 HD, and in the case of termination, about 35 HD, and is considered to be effective for determining the surface finishing work time. The possibility to do is expected.

  • PDF

Blast-load-induced interaction between adjacent multi-story buildings

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • v.17 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • The present study aims to present a comprehensive understanding of the performance of neighboring multi-story buildings with different dynamic characteristics under blast loads. Two different scenarios are simulated in terms of explosion locations with respect to both buildings. To investigate the effect of interaction between the neighboring buildings in terms of the induced responses, the separation gap is set to be sufficiently small to ensure collisions between stories. An adequately large separation gap is set between the buildings to explore responses without collisions under the applied blast loads. Several blast loads with different peak pressure intensities are employed to perform the dynamic analysis. The finite-element toolbox Computer Aided Learning of the Finite-Element Method (CALFEM) is used to develop a MATLAB code to perform the simulation analysis. The dynamic responses obtained in the scenarios considered herein are presented comparatively. It is found that the obtained stories' responses are governed mainly by the location and intensity of the applied blast loads, separation distances, and flexibility of the attacked structures. Moreover, explosions near a light and flexible building may lead to a significant decrease in blast resistance because explosions severely influence the dynamic responses of the building's stories.

A Study on the Pingzuo Structure of the Two-Story Building with One Roof in the Early Period of Tang Dynasty (당 전기 단첨누각의 평좌 구조 연구)

  • Baik, So-Hun
    • Journal of architectural history
    • /
    • v.30 no.3
    • /
    • pp.21-31
    • /
    • 2021
  • This paper studied the Pingzuo(平坐) platform structure of the two story building covered with one roof during the early period of Tang dynasty, based on wall paintings, stone pagodas, brick buildings and wooden buildings might be influenced by the Tang style. Instead of Chazhuzao(叉柱造), the typical column linkage in the Song, Liao and Jin buildings, it put the boundary column just behind the wall of a bracket set. Otherwise, the column root might be seen from outside, because its bracket set was still using Touxinzao(偸心造) which did not have a lateral arm on it. And its flooring structure was also different from the Song style, it used cantilever beams instead of lateral beams supported by bracket sets.

MAINTENANCE PERFORMANCE EVALUATION OF THE BUILDINGS IN THE DESIGN PHASE

  • Hakyu Baeck;Chansik Lee
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.1138-1143
    • /
    • 2005
  • As the importance of building maintenance is being emphasized, studies regarding the efficient building maintenance focus on the evaluation of the maintenance plan, implementation and its cost only while the evaluation of the maintenance performance is nearly ignored. At this point when the importance is placed on the performance design we need to have methods to improve maintenance performance of the buildings in Design Phase. The purpose of this study was to set the design evaluation items to improve the maintenance performance of the buildings. Through the review of the existing literature, we set the concept of the maintenance performance and suggested evaluation items to evaluate the maintenance performance through the analysis of domestic and overseas certification and design guidelines.

  • PDF

Comparison of Quality Standards for Aggregates of Concrete between Korea and China (한국과 중국간 콘크리트용 골재의 품질 규정 비교)

  • Hu, Yun-Yao;Han, Soo-Hwan;Lim, Gun-Su;Han, Jun-Hui;Yoon, Chi-Whan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.105-106
    • /
    • 2022
  • In this study, the classification, particle size, physical properties, and harmful substance contents of aggregates were compared in the standards between Korea and China. As a result of the analysis, although Korea and China are geographically adjacent from a global perspective, there are many differences in standards. In other words, it is analyzed that the standard was set due to the influence of the United States and Japan in Korea, while the standard was set due to the influence of Europe and Russia in China.

  • PDF

Prediction of concrete mixing proportions using deep learning (딥러닝을 통한 콘크리트 강도에 대한 배합 방법 예측에 관한 연구)

  • Choi, Ju-hee;Yang, Hyun-min;Lee, Han-seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.30-31
    • /
    • 2021
  • This study aims to build a deep learning model that can predict the value of concrete mixing properties according to a given concrete strength value. A model was created for a total of 1,291 concrete data, including 8 characteristics related to concrete mixing elements and environment, and the compressive strength of concrete. As the deep learning model, DNN-3L-256N, which showed the best performance on the prior study, was used. The average value for each characteristic of the data set was used as the initial input value. In results, in the case of 'curing temperature', which had a narrow range of values in the existing data set, showed the lowest error rate with less than 1% error based on MAE. The highest error rate with an error of 12 to 14% for fly and bfs.

  • PDF