• Title/Summary/Keyword: Set Building

Search Result 1,449, Processing Time 0.026 seconds

APPLICATION OF SPACE SYNTAX FOR PARTITION SEQUENCING OF WORKING SPACE IN BUILDING CONSTRUCTION

  • Li-Wen Wu;Sy-Jye Guo
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.573-582
    • /
    • 2007
  • Working spaces in the construction site are much more complicated than completed spaces in the building. There are many researches focus on partition of building spaces. However, few discussed partition sequencing in building construction sites. Space syntax is a set of techniques for analyzing spatial configurations. It has become a useful tool in a variety of researches. Partition sequencing of working spaces should be related to the working direction. However, with convex space and axial line, the partition sequencing became unrelated to the working direction. When critical space is blocked, the partition sequencing with axial line will be changed. It is significant to reveal the impact of the entire spatial structure when some of the working spaces are blocked. This paper discussed the improved partition sequencing theory and highlighted the importance of critical space and analyzed the spatial structure of working space. A real case project was demonstrated in this paper.

  • PDF

A Study on the Legislation Types and Prescriptions of American Earth Building Codes (미국 흙건축 법규의 법제화 유형 및 규제내용 분석)

  • Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.19-26
    • /
    • 2008
  • The purpose of this study is to analyze the legislation types and prescriptions of American earth building codes. The process of this study is as follows: (1) To understand the legislation background of American earth building codes, this study investigated the history and present state of earth building techniques which is used in USA. (2) To understand the legislation method and procedure of American earth building codes, this study investigated the legislation system of American building codes and the process of model building codes development and adoption. (3) To provide basic data for the legislation of Korean earth building codes or guidelines, this study analyzed American earth building codes about adobe, compressed earth block and rammed earth. The result of this study is as follows: (1) To meet need of a single coordinated set of national model building codes in the United States, the nation's three model code groups decided to form the International Code Council and the first edition of the International Building Code was published in 1997. In the International Building Code there are prescriptions on adobe construction. (2) There are three legislation types of earth building codes in USA. First is to use prescriptions of International Building Code on adobe construction. Second is that State governments establish and issue a separate document under its own title. The last is that local jurisdictions adopt International Building Code with amendments or additional rules. (3) On the base of analysis of American earth building codes, this study proposed the legislation process and direction of Korean earth building codes and guidelines.

Urban Area Building Reconstruction Using High Resolution SAR Image (고해상도 SAR 영상을 이용한 도심지 건물 재구성)

  • Kang, Ah-Reum;Lee, Seung-Kuk;Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.4
    • /
    • pp.361-373
    • /
    • 2013
  • The monitoring of urban area, target detection and building reconstruction have been actively studied and investigated since high resolution X-band SAR images could be acquired by airborne and/or satellite SAR systems. This paper describes an efficient approach to reconstruct artificial structures (e.g. apartment, building and house) in urban area using high resolution X-band SAR images. Building footprint was first extracted from 1:25,000 digital topographic map and then a corner line of building was detected by an automatic detecting algorithm. With SAR amplitude images, an initial building height was calculated by the length of layover estimated using KS-test (Kolmogorov-Smirnov test) from the corner line. The interferometric SAR phases were simulated depending on SAR geometry and changable building heights ranging from -10 m to +10 m of the initial building height. With an interferogram from real SAR data set, the simulation results were compared using the method of the phase consistency. One of results can be finally defined as the reconstructed building height. The developed algorithm was applied to repeat-pass TerraSAR-X spotlight mode data set over an apartment complex in Daejeon city, Korea. The final building heights were validated against reference heights extracted from LiDAR DSM, with an RMSE (Root Mean Square Error) of about 1~2m.

Effect of Wave Load on the Member Force of Steel Structure of Floating Buildings

  • Lee, Young-Wook;Park, Tae-Jun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1431-1439
    • /
    • 2018
  • For floating buildings may fl oat on the water for a long time, they are constantly affected by various environmental loads such as wind and wave loads. In this study to find the wave effect on the floating building, five models are designed using steel moment resisting frame. It is assumed that the lower part of the floating building is a reinforced concrete pontoon, while the upper part is a three-story steel frame. To analyze floating buildings affected by wind and wave loads, hydro-dynamic and substructure analysis are performed. As input loads, this study set limits that the mean wind velocity is 35 m/s and the significant wave height is 0.5 m for the residential building. From the hydrodynamic analysis, the time-history acceleration of building is obtained and transformed into a base ground input for a substructure analysis of the superstructure of the building. Finally the mean of the maximum from 30 dynamic analysis of the floating buildings are used to be compared with the results of the same model on the ground. It was shown that the dynamic results with wind and wave loads are not always lesser than the static results which are calculated with static equivalent wind load for a building that is located on the ground.

Estimation and Feature of Greenhouse Gas Emission in Building Sector by National Energy Statistic (국가 에너지통계에 따른 건물부문 온실가스 배출량 추계 및 특성)

  • Jeong, Young-Sun;Kim, Tae-Hyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.187-195
    • /
    • 2019
  • In December 2015, The Paris Agreement was adopted to undertake ambitious efforts to combat climate change. Korean government announced its goal of reducing the country's greenhouse gas emissions by up to 37% below business as usual projections by 2030 in 2015. The purpose of this study was to set up the calculation methodology of GHG emission($CO_{2e}$) in building sector and to estimate the annual GHG emission in building sector based on national energy consumption statistic. The GHG emission from buildings is about 135.8 million ton $CO_{2e}$ as of 2015, taking up about 19.6% of Korea's entire emission and is about 144.7 million ton $CO_{2e}$ in 2017. The GHG emission of building sector is increasing at annual rate of 2.0% from 2001 to 2017. The GHG emission from electricity consumption in buildings is 91.8 million ton $CO_{2e}$ in 2017, is the highest $CO_2$ emission by energy source. The results show that the intensity of GHG emission of residential building sector is $40.6kg-CO_{2e}/m^2{\cdot}yr$ and that of commercial building sector is $68.4kg-CO_{2e}/m^2{\cdot}yr$.

Anomaly Detection and Diagnostics (ADD) Based on Support Vector Data Description (SVDD) for Energy Consumption in Commercial Building (SVDD를 활용한 상업용 건물에너지 소비패턴의 이상현상 감지)

  • Chae, Young-Tae
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.579-590
    • /
    • 2018
  • Anomaly detection on building energy consumption has been regarded as an effective tool to reduce energy saving on building operation and maintenance. However, it requires energy model and FDD expert for quantitative model approach or large amount of training data for qualitative/history data approach. Both method needs additional time and labors. This study propose a machine learning and data science approach to define faulty conditions on hourly building energy consumption with reducing data amount and input requirement. It suggests an application of Support Vector Data Description (SVDD) method on training normal condition of hourly building energy consumption incorporated with hourly outdoor air temperature and time integer in a week, 168 data points and identifying hourly abnormal condition in the next day. The result shows the developed model has a better performance when the ${\nu}$ (probability of error in the training set) is 0.05 and ${\gamma}$ (radius of hyper plane) 0.2. The model accuracy to identify anomaly operation ranges from 70% (10% increase anomaly) to 95% (20% decrease anomaly) for daily total (24 hours) and from 80% (10% decrease anomaly) to 10%(15% increase anomaly) for occupied hours, respectively.

Analysis of Window Thermal Performance according to Guidelines on the Balcony Expansion Costs (발코니 확장비용 가이드라인에 따른 창호 열성능 분석)

  • Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.863-868
    • /
    • 2008
  • In accordance with the guidelines on the balcony structure changes in December 2005, most of tenants were moving into apartment housing, expand the balcony, but some large deviation between the price construction costs set of cases, due to overuse and the cause of the dispute, and the housing law amended in 2007 due to price cap system is implemented, the cost of expansion the balcony overdose pointed out that there is set to boost the sale price has been raised. These issues in order to improve the government in January 2008, the "Note costs by the balcony expansion" suggested guidelines to protect the rights of tenants and wants to promote the settlement of the sale price cap system. This study calculated the "Note costs by the balcony expansion" window system based on double or single, high performance insulation window system of the quantitative performance analysis of each type window that purpose.

  • PDF

Building an Annotated English-Vietnamese Parallel Corpus for Training Vietnamese-related NLPs

  • Dien Dinh;Kiem Hoang
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.103-109
    • /
    • 2004
  • In NLP (Natural Language Processing) tasks, the highest difficulty which computers had to face with, is the built-in ambiguity of Natural Languages. To disambiguate it, formerly, they based on human-devised rules. Building such a complete rule-set is time-consuming and labor-intensive task whilst it doesn't cover all the cases. Besides, when the scale of system increases, it is very difficult to control that rule-set. So, recently, many NLP tasks have changed from rule-based approaches into corpus-based approaches with large annotated corpora. Corpus-based NLP tasks for such popular languages as English, French, etc. have been well studied with satisfactory achievements. In contrast, corpus-based NLP tasks for Vietnamese are at a deadlock due to absence of annotated training data. Furthermore, hand-annotation of even reasonably well-determined features such as part-of-speech (POS) tags has proved to be labor intensive and costly. In this paper, we present our building an annotated English-Vietnamese parallel aligned corpus named EVC to train for Vietnamese-related NLP tasks such as Word Segmentation, POS-tagger, Word Order transfer, Word Sense Disambiguation, English-to-Vietnamese Machine Translation, etc.

  • PDF

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF

Fuzzy Control Application Strategy for Energy Saving in HVAC System (공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF