• 제목/요약/키워드: Servo Actuator

검색결과 259건 처리시간 0.035초

비접촉 평면 구동기의 자기력 조합 방식 구동 원리 (A Study on the Driving Principles of a Novel Non-contact Surface Actuator Using Combination of Magnetic Force)

  • 정광석;백윤수
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.115-121
    • /
    • 2001
  • In micro automation technology, the concurrent realization of a high resolution and a large operating rage has been achieved by a dual actuator, usually called by piggy-back system, conventionally. But, because of its manufacturing cost, the complexity of control, and the limit of overall bandwidth, the contract-free and single servo actuators have been suggested with specific applications. In this paper, we suggest a novel non-contact surface actuator suing combination of the Lorentz force and the magnetized force, and discuss the actuating principles including an analytical approach. Differently from the existing planar system, an operating range of the suggested system can be expanded by an additional attachment of active elements. Therefore, it is estimated to be suitable for the next-generation moving system.

  • PDF

전력설비 대용량 보일러 통풍기 날개각 제어 작동기 모델링 (Modelling of Power Plant Fan Pitch Blade Control Actuator)

  • 허준영;손태하
    • 유공압시스템학회논문집
    • /
    • 제4권2호
    • /
    • pp.28-33
    • /
    • 2007
  • In the power plant facility which use soft coal as a power source the fan pitch blade control hydraulic actuator is used to control the inlet and outlet gas to regulate the internal pressure of the furnace and control the frequence. Sometimes malfunctions of this equipment lead to the decline of boiler thermal efficiency and unexpected power plant trip. In order to localize the fan pitch blade control hydraulic actuator specially for the 500MW large scale boiler, Analysis and modelling of the system is carried out mathematically. The responses of the system are examined by using matlab simulation fur the variation of the major parameters in view of reverse engineering. Consequently the validity of the established parameters are examined.

  • PDF

디젤엔진 위치서보시스템을 위한 고장 식별 (Fault Isolation for a Diesel Engine Actuator)

  • 박태건;허학범;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.417-419
    • /
    • 1998
  • In a large diesel engine actuator position servo system, it is impossible to isolate an actuator fault from a load torque with conventional fault detection isolation (FDI) schemes because they are propagated through a channel. This paper deals with a parity equation based residual generation to isolate them in the system. The actuator fault is modelled by a multiplicative type fault that can be characterized as discrepancies between the nominal and actual plant parameters, whereas the load torque is modelled by an additive disturbance. The transformation implemented in the residual generator should be determined on-line to achieve the isolation. Simulation studies show the practical applicability of the FDI scheme.

  • PDF

디스크 형 홀로그램 정보저장장치를 위한 광축상 서보 컨트롤 (On-axis servo control in pickup actuator for disk type holographic data storage)

  • 김성필;송석호;오차환;김필수;김지덕;이홍석
    • 한국광학회지
    • /
    • 제14권1호
    • /
    • pp.58-64
    • /
    • 2003
  • 대용량 홀로그램 정보저장장치를 현재의 CD-ROM과 같이 디스크 형으로 구현하는데 있어서, 저장된 데이터를 정확하게 읽어내기 위한 픽업 모듈의 서보 컨트롤은 매우 중요하다 디스크 및 회전 모터의 요동에서 오는 기계적 오차를 보정하기 위해, 데이터 재생 시 광축상에 한 장의 평판유리를 사용하는 새로운 서보 컨트롤 방식을 제안하였다. 평판유리를 $\pm$$10^{\circ}$이내에서 회전시킴으로써, $\pm$200 $\mu\textrm{m}$ 정도의 오차범위를 $\pm$150 $\mu\textrm{m}$ 이내로 컨트롤하여 재생오차를 92.5% 이상 줄일 수 있었다.

Robust motion control of a flexible micro-actuator using $H_{\infty}$ control method

  • Okugawa, Masayuki;Sasaki, Minoru;Fujisawa, Fumio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.397-400
    • /
    • 1996
  • In this paper, robust motion control of a flexible micro-actuator is presented. The actuator is made of a bimorph piezoelectric high-polymer material (PVDF). No mathematical model system can exactly model a physical system such a flexible micro-actuator. For this reason we must be aware of how modeling errors might adversely affect the performance of a control system for such a model. The H method addresses a wide range of the control problems, combining the frequency and time domain approaches. The design is an optimal one in the sense of minimization of the maximum of the closed-loop transfer function. It includes colored measurement and process noise. It also addresses the issues of robustness due to model uncertainties, and is applicable to the, flexible micro-actuator control problem. Therefore, we adopt the H control problem to the robust motion control of the flexible micro-actuator. Theoretical and experimental results demonstrate the satisfactory performance and the effectiveness of the designed controller. the effectiveness of the designed controller.

  • PDF

가동 자석형 3 축 구동 엑츄에이터 (3-axis Moving Magnet Type Actuator)

  • 허영준;송명규;박노철;유정훈;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1033-1036
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to equip 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added tilting mechanism to 2-axis moving magnet actuator which is designed in previous research. Addition of the tilting mechanism cuts down the focusing sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

Vibration Analysis of HDD Actuator with Equivalent Finite Element Model of VCM Coil

  • Kim, Dong-Woohn;Lee, Jin-Koo;Park, No-Cheol;Park, Young-Pil
    • Journal of Mechanical Science and Technology
    • /
    • 제17권5호
    • /
    • pp.679-690
    • /
    • 2003
  • As the rate of increase in areal density of the HDD has accelerated, dynamic characteristics of the HDD actuator need to be improved with respect to the performance of the tracking servo and shock transmission. Therefore, it is important to analyze the vibration characteristic of the HDD actuator that consists of the VCM part, E-block and pivot bearing. In this paper, vibration modes of the HDD actuator are investigated the using finite element and experimental modal analyses methods. To develop a detailed finite element model, finite element models of each components of the actuator assembly are constructed and tuned to the results of the EMA. The VCM coil is modeled as an equivalent finite element model that has an orthotropic material property using auto-model updating program. Auto-model updating program with improved sensitivity based iterative method is applied to build a detailed finite element model using the result of the EMA. A detailed finite element model of the HDD actuator is then constructed and analyzed.

가동 자석형 3 축 구동 엑츄에이터 개발 (Development of 3-axis Moving Magnet Type Actuator)

  • 송명규;허영준;박노철;유정훈;박영필
    • 정보저장시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.191-195
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to be equipped with 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added a tilt mechanism to the 2-axis moving magnet actuator which is designed in previous research. Addition of the tilt mechanism cuts down the focus sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정 (Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit)

  • 장지팡;김춘택;정헌술
    • 유공압시스템학회논문집
    • /
    • 제4권4호
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

고밀도 디스크 드라이브의 안착시간 최소화 제어 (Control For Minimizing Settling Time in High-Density Disk Drives)

  • 강창익;김창환;임충혁
    • 제어로봇시스템학회논문지
    • /
    • 제9권1호
    • /
    • pp.10-21
    • /
    • 2003
  • During seek operation in disk drives, the recording head is moved toward desired track by seek servo controller and then is settled onto the center of the desired track by settling servo controller. If the head speed at the start of settling servo control is not slow, it may produce overshoot relative to the center of track and thus extend the settling time. The degradation in settling performance will be more severe as the track width becomes smaller for higher density of data storage. We design a new settling servo controller for minimizing settling time based on the pole-zero cancellation. In order to cancel slow poles in settling response, we apply discrete pulse signals to the system in addition to the state feedback control. For exact pole-zero cancellation, we consider the dynamics of power amplifier used for actuator current regulation and the effects of delay in control action. In addition, we present system parameter identification algerian for the robustness of our controller to system parameter variation. In order to demonstrate the practical use of our controller, we present experimental results obtained by using a commercially available disk drive.