• 제목/요약/키워드: Service line

검색결과 1,759건 처리시간 0.026초

송전선로의 동기페이저를 이용한 고장점 표정장치 (Fault Locator using GPS Time-synchronized Phasor for Transmission Line)

  • 이경민;박철원
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.47-52
    • /
    • 2016
  • Fault location identification in the transmission line is an essential part of quick service restoration for maintaining a stable in power system. The application of digital schemes to protection IEDs has led to the development of digital fault locators. Normally, the impedance measurement had been used to for the location detection of transmission line faults. It is well known that the most accurate fault location scheme uses two-ended measurements. This paper deals with the complete design of a fault locator using GPS time-synchronized phasor for transmission line fault detection. The fault location algorithm uses the transmitted relaying signals from the two-ended terminal. The fault locator hardware consists of a Main Processor Unit, Analog Digital Processor Unit, Signal Interface Unit, and Power module. In this paper, sample real-time test cases using COMTRADE format of Omicron apparatus are included. We can see that the implemented fault locator identified all the test faults.

ATM 기반 HDSL 개발, 동 선로 상의 성능 평가 및 서비스 구현 (A System Development, Performance Assessment, and Service Implementation of ATM-based High-rate Digital Subscriber Line (HDSL))

  • 양충열
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1562-1574
    • /
    • 1998
  • 본 논문에서는 ATM(Asynchronous Transfer Mode) 교환기 시스템에 T1, E1 및 부분적으로 E1급 속도의 중 저속 HDSL(High-rate digital subscriber line) 정합 기능을 개발하고, 근단누화(NEXT), 임펄스. 선로 잡음(power line noise) 및 접지 임피던스(longitudinal) 잡음 같은 주요 전송 손실이 존재하는 0.4 mm 및 0.5 mm의 기존 전화가입자 선로(UTP, Unshielded twisted pair)를 사용하는 CSA(Carrier serving areas) 선로 모델을 이용하여 $10^{-7}$의 BER(Bit error rates)의 전송 성능을 만족하기 위한 가입자 서비스 전송 거리 성능을 평가하였다. HDSL은 DSI, ISDN 기본 속도 접속 및 DLC 피더에 사용될 것이며 광 케이블과 인터페이스될 것이다. 또한, HDSL 시잔 전망을 제시한다.

  • PDF

송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용 (Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units)

  • 조기선;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

철도 공익서비스비용 보상기준 개선방안 연구 (A Study for Revising Compensation Criteria of Public Service Rail Transport)

  • 이장호;이상훈;강욱
    • 대한교통학회지
    • /
    • 제26권1호
    • /
    • pp.65-78
    • /
    • 2008
  • 2005년 철도구조개혁 시행에 따라 한국철도공사가 출범하였고, 철도운영자가 제공하는 공익서비스비용에 대하여는 철도산업발전기본법 제32조 및 제33조에 의해 원인제공자가 보상토록 규정하고 있다. 이에 따라 공익서비스비용의 보상은 '05년도 처음 시행되었으나, 비용 산정의 적정성 및 기준 미비 등으로 보상규모의 공정성 객관성에 대한 외부기관으로부터 문제가 제기되었다. 따라서 본 연구에서는 국내외 유사사례를 검토하고, 공익서비스비용 보상의 주요항목인 벽지노선의 적정한 선정기준 및 비용 산출, 운임감면액 보상범위 등과 관련하여 문제점과 개선방안을 살펴보았다.

송전선로의 유효전력 손실을 각 부하에 배분하는 방법 (An Approach to Allocate Real Power Losses of Transmission Lines to Individual Loads)

  • 노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.13-18
    • /
    • 2000
  • The paper proposes a simple method to calculate the portion of real power losses of transmission lines allocated to individual loads. The method is implemented by defining loss distribution factors, and analyses the loads shares in the transmission line losses. The paper also performs calculation of sensitivities of the line losses with respect to load changes so as to be easily employed in on-line applications. Effectiveness of the algorithm is verified by computer simulations and it is estimated that the results can be used to compute the cost of one ancillary service under deregulated environment in electric power industries.

  • PDF

양전원 송전선로의 고장점 표정 알고리즘 (Fault Location Algorithm in a Two-ended Sources Transmission Line)

  • 박철원
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.18-24
    • /
    • 2016
  • In order to service restoration and enhance power system reliability, a number of impedance based fault location algorithms have been developed for fault locating in a transmission line. This paper presents an advanced impedance-based fault location algorithms in a two-ended sources transmission line to reduce the DC offset error effects. This fault location algorithm uses of the GPS time synchronized voltage and current signals from the local and remote terminal. The algorithm uses an advanced DC offset removal filter. A series of test results using ATPdraw simulation data show the performance effectiveness of the proposed algorithm. The proposed algorithm is valid for a two-end sources transmission network.

가동중 정비를 위한 Risk Monitor 개발 (Risk Monitor Development for On-Line Maintenance)

  • 김길유;한상훈;김태운
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 1997
  • Korea Atomic Energy Research Institute (KAERI) developed a risk monitor called Risk Monster which supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Risk Monster can update the plant risk continuously according to the change of system/component configuration since Risk Monster reevaluates the plant risk based on the Probabilistic Safety Assessment (PSA) results. A brief description of Risk Monster is provided. The PSA model of UCN 3, 4 nuclear power plant was converted by KAERI to Risk Monster model. Using this Risk Monster model, a feasibility study of the on-line maintenance of an Essential Service Water (ESW) pump was performed. On-line maintenance of one ESW pump has been shown to be acceptably safe, and has economic benefits. In addition, it is not a violation of technical specification to continue plant operation with an out-of-service ESW pump.

  • PDF

문경선 운영 재개에 따른 이용수요 예측 연구 (A Study on forecasting of the Transportation Demand Mungyeng Line)

  • 김익희;이경태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.638-644
    • /
    • 2008
  • Mungyeng line(Jupyung${\sim}$Mungyeng) was closed due to a rapid decrease in demand in 1995. However, as the rail transportation demand is expected to increase with the plan to develop a tourist resort and a traffic network in Mungyeng area, it is required to forecast future demand to meet the change of transportation environment in this region. This study predicts the rail transportation demand and analyzes financial benefit in operator's side in case of reopening this line, based on nation-wide traffic volume data from Korean Transportation Database(KTDB). The results of this research can be applied to not only establishing a train operation plan also improving customer service. Moreover, Korail will have an opportunity to develop new business by linking train service to tourist attractions around the Mungyeng area.

  • PDF

서비스 교환기에서의 정보료수납대행 서비스 구현에 관한 연구 (A Study on the Implementation of the Premium Service in SSP)

  • 홍선미;김기령;김태일;이형호;김영시
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.473-475
    • /
    • 1993
  • Premium Service is the next service to be developed after the Freephone Service and Credit Call Service which has currently been developed and is being now tested. Premium Service is a service which provide information on a telephone line. The calls are charged with a special rate which includes service and call charge. Public telecommunication operator performs charging and accounting from the service user for the service provider and for every service provided subtracts the commission from the part of service revenue and gives the rest back to the service provider. This paper is about the study on the implementation of the Premium Service in the Service Switching Point.

  • PDF

ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.