• 제목/요약/키워드: Serum samples

검색결과 1,272건 처리시간 0.026초

Harmonization of laboratory results by data adjustment in multicenter clinical trials

  • Lee, Sang Gon;Chung, Hee-Jung;Park, Jeong Bae;Park, Hyosoon;Lee, Eun Hee
    • The Korean journal of internal medicine
    • /
    • 제33권6호
    • /
    • pp.1119-1128
    • /
    • 2018
  • Background/Aims: In multicenter clinical trials, laboratory tests are performed in the laboratory of each center, mostly using different measuring methodologies. The purpose of this study was to evaluate coefficients of variation (CVs) of laboratory results produced by various measuring methods and to determine whether mathematical data adjustment could achieve harmonization between the methods. Methods: We chose 10 clinical laboratories, including Green Cross Laboratories (GC Labs), the central laboratory, for the measurement of total cholesterol, high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), serum triglycerides, creatinine, and glucose. The serum panels made with patient samples referred to GC Labs were sent to the other laboratories. Twenty serum samples for each analyte were prepared, sent frozen, and analyzed by each participating laboratory. Results: All methods used by participating laboratories for the six analytes had traceability by reference materials and methods. When the results from the nine laboratories were compared with those from GC Labs, the mean CVs for total cholesterol, HDL-C, LDL-C, and glucose analyzed using the same method were 1.7%, 3.7%, 4.3%, and 1.7%, respectively; and those for triglycerides and creatinine analyzed using two different methods were 4.5% and 4.48%, respectively. After adjusting data using Deming regression, the mean CV were 0.7%, 1.4%, 1.8%, 1.4%, 1.6%, and 0.8% for total cholesterol, HDL-C, LDL-C, triglyceride, creatinine, and glucose, respectively. Conclusions: We found that more comparable results can be produced by laboratory data harmonization using commutable samples. Therefore, harmonization efforts should be undertaken in multicenter trials for accurate data analysis (CRIS number; KCT0001235).

Incidence of exercise-associated hyponatremia during a high-altitude 161-km ultramarathon

  • Khodaee, Morteza;Saeedi, Anahita;Harris-Spinks, Christine;Hew-Butler, Tamara
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.16-22
    • /
    • 2021
  • [Purpose] Exercise-associated hyponatremia (EAH) is a well-known condition among endurance athletes at low altitudes. The incidence of EAH during ultramarathons at high altitudes warrants further investigation. This prospective observational study was conducted on the participants of the Leadville Trail 100 run, a 161-km race held at a high altitude (2,800 m-3,840 m). [Methods] Venous blood samples were collected before and immediately after the race. The participants completed an electronic survey after the race. Our main outcome measure was the post-race serum sodium ([Na+]) level. [Results] Of the 672 athletes who started the race, 351 (52%) successfully completed the event within the 30-hour cut-off. Post-race blood samples were collected from 84 runners (66 finishers). Both pre- and post-race blood samples were collected from 37 participants. Twenty percent of the post-race participants had EAH. Only one post-race participant had a [Na+] level of <130 mmol/L. All participants with EAH were asymptomatic. One participant had an abnormal pre-race [Na+] level (134 mmol/L). Female participants had a significantly higher rate of EAH than male participants (40% vs. 16%; p=0.039). Age, body mass index, weight changes, race completion status, nonsteroidal anti-inflammatory drug use, and urine specific gravity were not associated with the development of EAH. Lower postrace [Na+] levels were associated with higher serum creatine kinase values (R2=0.1, p<0.005). [Conclusion] High altitude (3,840 m peak) does not appear to enhance the incidence of EAH after an ultramarathon footrace. This suggests that ambient temperature (low temperatures reduce risk), sex (female predilection), endurance running, and overhydration are more prominent risk factors for EAH than high altitude.

Effects of Dietary Lysine Levels on Apparent Nutrient Digestibility and Serum Amino Acid Absorption Mode in Growing Pigs

  • Zeng, P.L.;Yan, H.C.;Wang, X.Q.;Zhang, C.M.;Zhu, C.;Shu, G.;Jiang, Q.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권7호
    • /
    • pp.1003-1011
    • /
    • 2013
  • Two experiments were conducted to determine the effects of different dietary lysine levels on the apparent nutrient digestibility, the serum amino acid (AA) concentration, and the biochemical parameters of the precaval and portal vein blood in growing pigs. In Experiment 1, 15 noncannulated pigs received diets with different lysine densities (0.65%, 0.95%, and 1.25% lysine) for 13 d. A total collection digestion test was performed, and blood samples were collected from the precaval vein at the end of the experiment. In Experiment 2, four cannulated pigs were fed the same diets of Experiment 1. The experiment used a self-control experimental design and was divided into three periods. On d 5 of each period, at 0.5 h before feeding and hourly up to 8 h after feeding, single blood samples were collected from catheters placed in the portal vein. In Experiment 1, some serum AAs (including lysine), serum urinary nitrogen (SUN), and total protein (TP) concentrations were significantly affected by the dietary lysine levels (p<0.05). Moreover, the 0.65% lysine treatment showed a significant lower apparent digestibility of gross energy, dry matter, crude protein, and phosphorus than the other treatments (p<0.05). In Experiment 2, serum lysine, histidine, phenylalanine, threonine, valine, isoleucine (p = 0.0588), triglyceride, and SUN (p = 0.0572) concentrations were significantly affected by the dietary lysine levels (p<0.05). Additionally, almost all of the determined serum AA and total AA concentrations reached their lowest values at 0.5 h before feeding and their highest values at 2 h after feeding (p<0.05). These findings indicate that the greatest absorption of AA occurred at 2 h after feeding and that the dynamic profile of serum AA is affected by the dietary lysine levels. Moreover, when the dietary lysine content was 0.95%, the growing pigs achieved a better nutrient digestibility and serum metabolites levels.

부산지역 바이러스성 성병 감염양상 연구 (Distribution of Sexually Transmitted Viral Diseases in Busan)

  • 조경순;나영란;조현철;이정희;정명주
    • 미생물학회지
    • /
    • 제42권3호
    • /
    • pp.177-184
    • /
    • 2006
  • 항구 도시인 부산의 바이러스성 성병 감염 현황과 고위험군 지표로서 HPV, HSV 및 HBV 감염자의 성별, 연령대별 유형율 조사 등 기초자료를 확보하여 성매개감염증 사업관리 및 전파방지에 중요한 자료를 제공하고자 한다. 자궁경부도찰물 674건 중 HPV 23건(3.4%)과 HSV 1 2형 3건(0.4%) 9건(1.3%)이 각각 분리되었으며, 혈청 586건 중 HSV IgM 121건(3.6%), HSV-1 IgG 487건(83.1%), HSV-2 IgG 135건(23.0%), HBsAg 26건(4.4%), HBeAg 7건 (1.2%) 등이 검출되었다. HPV 유전자형별 분포도는 고위험군이 15종(13명), 저위험군이 6종(3명)으로 나타났으며, 복합감염은 7명이었다. 연령별 발생분포는 자궁경부도찰물의 경우 20대 이하가 24건(7.2%), 혈청의 경우 40대 이상이 101건(100%)으로 가장 높았다. 그리고 업소별 분포도는 자궁경부도찰물에서 보건소의 검진대상자(유흥업소종사자)들이 감염율이 가장 높았고, 혈청에서는 대용성병진료소의 검진대상자(특수업태부)가 감염율이 가장 높았다.

Urinary Estrone Sulfate for Monitoring Pregnancy of Dairy Cows

  • Yang, C.J.;Wu, L.S.;Tseng, C.M.;Chao, M.J.;Chen, P.C.;Lin, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권9호
    • /
    • pp.1254-1260
    • /
    • 2003
  • The purpose of this study firstly was conducted to establish a radioimmunoassay (RIA) of estrone sulfate ($E_1S$), secondly to monitor the reproductive status of dairy cows using their urine samples. Urine and blood samples were collected in series within a day from four pregnant Holstein-friesian cows to evaluate the relationship between $E_1S$ levels in blood and urine with or without urinary creatinine basis. The urine was then collected biweekly from three cows in estrous and those artificially inseminated; collection from pregnant cows was made on a monthly basis. Results indicated that sensitivity for the $E_1S$ RIA was 5 pg/tube and the recovery rate was 100%. The daily urinary creatinine concentrations fluctuated within a day, but changes were slighter in midday, whereas the changes of concentrations of $E_1S$ in urine were relatively smaller. The concentrations of serum $E_1S$ during the estrous cycle were undetectable due to the limitation of assay, but the urinary $E_1S$ level could be measured with no obvious changes during the cycle. The urinary $E_1S$ levels increased remarkably around 7.7 to 8.3 ng/ml, 80 to 100 days after pregnancy but the serum $E_1S$ levels did not elevate until 120 to 150 days. The level of $E_1S$ increased gradually during pregnancy and eventually reached its peak before parturition at around 40 ng/ml and finally decreased to its basal level 2 days postparturition. During pregnancy, $E_1S$ concentrations of urine increased earlier than those in blood. The correlation coefficients between urinary and serum $E_1S$ concentration during pregnancy and postparturm were higher than those adjusted with creatinine (creatinine ratio). The concentrations of $E_1S$ in urine could be maintained unchanged for 8 days storing the samples in room temperature, which was extended to 8 days when the samples were pretreated by boiling for 30 minutes or treated with autoclave. In conclusion urinary $E_1S$ concentrations can be used directly for monitoring the pregnant status and fetal viability of dairy cows and can assist accurate confirmation of pregnancy in cows at least 80 to 100 days after insemination much earlier than by serum $E_1S$.

Significant Correlation between Salivary and Serum Ca 15-3 in Healthy Women and Breast Cancer Patients

  • Laidi, Fatna;Bouziane, Amal;Lakhdar, Amina;Khabouze, Samira;Amrani, Mariam;Rhrab, Brahim;Zaoui, Fatima
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4659-4662
    • /
    • 2014
  • The tumor marker CA 15-3 is one of the most import reliable for metastatic breast cancer monitoring. While it is generally assessed in serum of patients, blood sampling is an invasive method compared to saliva sampling which is simple and could be an alternative to blood according to many studies. The aim of this investigation was to assess the relationship between serum and salivary concentrations of the protein CA 15-3 in patients with breast cancer and healthy asymptomatic volunteers. A case-control study was conducted with 60 women: 29 breast cancer patients from the Maternity Hospital Souissi Rabat (Morocco) and 31 healthy asymptomatic women. The CA 15-3 concentrations in saliva and serum samples were assessed using an enzyme immune assay (EIA kits) and comparison between cases and controls was made by the Mann-Whitney test. The correlation between serum and saliva CA 15-3 concentration was tested using Pearson correlation. The comparison result of CA15-3 concentration in saliva and serum level in cases and controls was not statistically significant (p>0.05). However, the correlation between salivary and serum CA 15-3 concentration was positive and statistically significant (r=0.27, p=0.03). In conclusion, the positive correlation between salivary and serum expression found in our study suggests that saliva could be an alternative to blood sampling to help breast cancer monitoring.

임신부와 신생아의 철분 영양상태에 관한 연구 (Iron Status in Pregnant Women and Their Newborn Infants)

  • 김은경
    • Journal of Nutrition and Health
    • /
    • 제32권7호
    • /
    • pp.793-801
    • /
    • 1999
  • The purposes of this study are to assess iron status in mothers and their newborn infants at birth and to analyze the influence of maternal iron status on their newborn babies. Venous bloods samples were drawn from 144 pregnant women just before delivery and cord bloods of their newborn babies were collected immediately after birth for measurement of hemoglobin, hematocrit, serum iron, ferritin, total binding capacity and transferrin saturation. The values of hemoglobin and hematocrit were significantly lower in the mothers(10.9$\pm$1.43g/dl and 33.7$\pm$3.67%) than in their newborn infants(14.7$\pm$1.43g/dl and 45.3$\pm$4.76%)(p<0.0001). At delivery, serum iron levels in cord blood were about twice as high as those in the maternal blood, and serum ferritin levels in the cord blood were about four times higher than those in the maternal blood. The serum ferritin levels of multigravidas were higher than those of primigravidas,. but there was no difference between the serum ferritin levels of their infants. The serum ferritin levels of the mothers and their infants were higher in maternal group with iron supplement regularly than in other maternal group without iron supplement during pregnancy. Among the mothers, 26.4% had a serum ferritin levels below 12ng/ml(i.e. depleted iron stores)and 78.9% had a hemoglobin below 12g/dl(i.e.iron deficient anemia). When the maternal group was classified according to their serum ferritin levels by 9ng/ml, 12ng/dl or 20ng/ml, there was no significant difference in the iron status of their newborn infants among the three groups. The hemoglobin and serum ferritin levels of the mothers were well correlated with those of their babies. The maternal hemoglobin values negatively correlated with infant birth weight. It is possible that the demands of iron of the mother might be increased in the case of a newborn infant of greater size. The results of this study provide useful information regarding establishment of RDA for iron in pregnant women and guidance about the need for iron supplement during pregnancy.

  • PDF

닭혈청(血淸)에 의한 면양적혈구(緬羊赤血球)의 용혈(溶血)에 관한 연구(硏究) (Studies on hemolytic reaction of normal chicken serum and sheep erythrocytes)

  • 서익수
    • 대한수의학회지
    • /
    • 제14권1호
    • /
    • pp.77-90
    • /
    • 1974
  • Hemolytic reaction of normal fresh chicken serum on sheep erythrocytes was studied and the following experimental results were obtained and summarized. 1. Chicken sera, 258 (78%) out of 344 samples showed hemolytic activity on sheep erythrocytes. 2. Distribution of a different hemolytic titer of chicken sera was not dependent to sex and age difference of test chicken. 3. Hemolytic activity of serum component obtained from normal fresh chicken was heat inactivated at $56^{\circ}C$. 30 minutes heating. 4. The most enhanced hemolytic activity of chicken serum on sheep erythrocytes was observed at the incubation temperature of $46^{\circ}C$. 5. The most effective pH for the hemolytic reaction of chicken serum on sheep erythrocytes was observed at 7.0, and pH 6.0 or 8.5 resulted less or no hemolysis. 6. Hemolytic reaction of chicken serum and sheep erythrocytes required Mg⧻ and Ca⧻ ions as, co-factor, and the former was required more compared to the latter. 7. Hemolytic activity of chicken serum was observed in ChC 2, 4 fraction but not in ChC 1, 3, ChC 3, 4, ChC 1, 2, 4 and ChC 1, 2, 3 fractions. 8. In electron micrography, morphological changes of sheep erythrocyte membrane by normal chicken serum was similar to that of immune hemolysis: that was, the hemolytic hole was circular and it was surrounded with a white ring. 9. Electron micrography of morphological changes on sheep erythrocyte membrane indicated that the size of hemolytic hole and white ring were functional to the chicken serum concentration used and reaction time.

  • PDF

한약과 양약 복용이 신장기능에 미치는 영향 -피부과치료 한약복용 환자를 중심으로- (Effects of Kidney Function in Blood of Drug Users(Herbal and Western) in Koreans)

  • 신헌태;이선동
    • 대한예방한의학회지
    • /
    • 제8권2호
    • /
    • pp.157-169
    • /
    • 2004
  • We have conducted questionnaire and measured serum kidney function tests on 156 patients whom have received a treatment at a local Oriental medicine clinic in Seoul from Sept. 1, 2002 to Dec. 31, 2002. Patients were categorized into five groups. The groups are control(10 samples), herbal extract group(41 samples), herbal pills group(5samples), western medicines(45samples), and combination group(55 samples). This study was conducted to investigate how these treatment methods can affect the kidney functions. Following results were obtained : 1) Most of the research subjects were male(103 individuals) living in large urban area, with a drinking habit, highly educated, and with normal marriage. For the treatment history, 45 individuals received western medicine treatment(28.85%), 46 with Oriental medicine(29.49%), and 55patients (35.26%) experienced both forms of the treatment. 2) For measuring Mean(SD) of serum kidney functions for all the research subjects, Bun was 12.16(3.90)g/dl, 0.51(0.19) g/dl for Creatinine, and 4.64(1.49)g/dl for Uric acid. All the measurements were within the normal range. 3) Confounding variables which may affect the kidney functions such as age, smoking, drinking, occupation, and residency were eliminated in calculation and no significant differences were witnessed between the control and experiment groups. 4) In measuring affects of treatment duration on the kidney functions, no statistical significances were shown in multiple regression's ${\beta}(SE)$ values. 5) Correlations affecting the kidney functions are duration of drinking, drinking volume per round, drinking volume per week, smoking, gender, and age difference caused significant correlations. From the above results, we can deduce that taking herbal and western medicine didn't cause significant effects between the control and experiment groups in the kidney functions. Further research is needed in this field to verify this evidence by adding odds ratios and etc.

  • PDF

경북지역 산란계에서 avian pneumovirus 에 대한 항체가조사 (Serological survey of avian pneumovirus infection in laying hens of Gyeongbuk province)

  • 김순태;김성국;조민희;김영환
    • 한국동물위생학회지
    • /
    • 제26권1호
    • /
    • pp.51-56
    • /
    • 2003
  • Avian pneumoviros(APV), also known as avian rhinotracheitis virus(ARTV), affects both turkeys and chickens and is known to be the primary causative agent of turkey rhinotracheitis (TRT). The aim of this study was to establish the presence or absence of antibodies to avian pneumovirus in the commercial poultry population of Korea. For this purpose, chicken serum samples were obtained and tested by an enzyme-linked immunosorbent assay (ELISA). The tested serum was collected in laying hens with reduction of egg production or normal in Gyeongbuk province. A total of 184 sera representing 42 different poultry farms of the Gyeongbuk region of Korea were included in this study. Laying hens of 16 different farms with reduction of egg production and laying hens of 26 different farms with clinically healthy at the time of serum sampling were considered positive to antibody against APV. In the farms with reduction of egg production, positive farm to antibody against avian pneumovirus were 11 of 16 different farms(68.8%) and positive sera were 47(58.8%) of 80 different serum. In the farms with clinically healthy flock, positive farm to antibody against avian pneumovirus were 12(46.2%) of 26 different farms and positive serum sample were 39(37.5%) of 104 different sera. According to the results tested to 42 different farms in 14 city, 8 of 14 city have flocks with antibody positive laying hens against APV, 1 of 14 city have antibody suspicious and 5 of 14 city shown antibody negative, respectively.