• Title/Summary/Keyword: Series-series configuration

검색결과 333건 처리시간 0.021초

고 입력전압 전력변환 응용에 적합한 입력직렬-출력병렬 컨버터 시스템 (Input Series-Output Parallel Connected Converter System for High Voltage Power Conversion Applications)

  • 김정원;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.455-459
    • /
    • 1998
  • In this paper input Series-Output Parallel connected converter configuration for high voltage power conversion applications is proposed and a control method to solve the problems of Input Series-Output Paralles connected converter configuration is introduced. In this configuration snubber circuit or voltage balancing controller that is necessary for the series connection of switching devices is not needed. The effectiveness of this proposed configuration is verified by simulation.

  • PDF

Xilinx 7-Series FPGA의 소프트 에러에 대한 가용성 분석 (Availability Analysis of Xilinx 7-Series FPGA against Soft Error)

  • 류상문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.655-658
    • /
    • 2016
  • 고성능 디지털 회로 구현에 매우 많이 사용되는 Xilinx사의 7-Series FPGA(Field Programmable Gate Array)는 configuration memory가 SRAM 기반으로 제작되어 configuration memory에 소프트 에러(soft error)가 발생하는 경우 FPGA는 오동작하게 된다. Xilinx사에서 제공하는 SEM(Soft Error Mitigation) Controller를 이용하면 configuration memory에서 발생하는 소프트 에러의 영향을 줄일 수 있다. SEM Controller는 FPGA의 configuration memory 영역에 추가된 ECC(Error Correction Code)와 CRC(Cyclic Redundancy Code) 기능을 이용하여 configuration memory에 발생한 소프트 에러를 감지하여 필요시 partial reconfiguration 과정을 수행하여 FPGA의 기능을 소프트 에러 발생 이전으로 복구한다. 본 논문에서는 Xilinx사의 7-Series FPGA에서 SEM Controller를 이용하여 configuration memory의 소프트 에러를 검출하고 정정할 때 FPGA의 신뢰도를 가용성(availability) 관점에서 분석한다. 이를 위해 SEM Controller의 소프트 에러 정정 성능에 따른 가용성 함수를 유도하고 그 효과를 검토한다. 연구 결과는 소프트 에러가 발생하는 환경에서 동작하는 SRAM 기반 FPGA의 신뢰성 예측에 사용할 수 있을 것으로 기대된다.

  • PDF

Input Series-Output Parallel Connected Converter Configuration for High Voltage Power Conversion Applications

  • Kim, Jung-Won;You, J.S.;Cho, B.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.201-205
    • /
    • 1998
  • In this paper, the charge control with the input voltage feed forward is proposed for the input series-output parallel connected converter configuration for high voltage power conversion applications. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input-series connected modules for all operating conditions including the transients. It also offers the robustness for the component value mismatches among the modules.

  • PDF

고속전철 보조전원 장치용 입력직렬-출력병렬 컨버터의 제어 및 설계 (Control and Design of Input Series-Output Parallel Connected Converter for High Speed Train Power System)

  • 김정원;유정식;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.282-290
    • /
    • 2000
  • In this paper, the charge control with the input voltage feedback is proposed for the input series-output series-output parallel connected converter configuration for the high speed train power system application. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input series connected modules for all operating conditions including the transients. It also offers the robustness for the input voltage sharing control according to the component value mismatches among the modules. And this configuration enables the usage of MOSFET for a high voltage system allowing a higher switching frequency for lighter system weight and smaller size. The performance of the proposed scheme is verified through the experimental results.

  • PDF

전압 강하 및 전력 전달 유연성을 위한 직렬 및 분로 통합형 인버터 (Integrated Series and Shunt Inverter for Voltage Sag and Power Transfer Flexibility)

  • ;배성진;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.141-142
    • /
    • 2017
  • In this paper, integrated series and shunt inverter is presented to solve power quality problems in distribution line system. In this configuration consists of series inverter and shunt inverter. Series inverter acts as DVR to compensate voltage during sagging occurred and shunt inverter optimize to inject balance active power from distributed power source like PV system with Maximum Power Point Tracing (MPPT). Finally, the proposed configuration is verified through the PSiM simulation.

  • PDF

그림자 영향과 태양광 어레이 구조에 따른 최대발생전력 비교 해석 및 실험 (Comparison of maximum generated power by shading effect and PV array configurations)

  • 김의종;유병규;차한주;유권종
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.8-13
    • /
    • 2009
  • In this paper, two configurations of PV array are analyzed and tested under shading condition, where two configurations are series-parallel and total-crass-tied configuration. Each photovoltaic module is emulated by two 5 inch po1y-crystalline cells in series and an array is constructed by connecting 24 of the modules to compare a generated maximum power of the two configurations. Pspice and Sun simulator. PASAN IIIb, are used for simulation and experiment to test the array under various partial shading conditions. Test results show the total-cross-tied configuration generates 7.63% higher maximum power than the series-parallel configuration, and it is well matched to the analysis and simulations of the two configurations.

화학처리(化學處理) Silica의 SBR에 대한 보강효과(補强效果)에 관(關)한 연구(硏究) (Study on the Chemical Treatment of Silica for SBR Reinforcement)

  • 박건록;유종선;최세영
    • Elastomers and Composites
    • /
    • 제29권1호
    • /
    • pp.18-29
    • /
    • 1994
  • The purpose of this study is to investigate reinforced effect between silica treated by coupling agents and rubber matrix under the configuration chemical bonds, and the effect of silica particles coated by organic polymers using aluminum chloride as the catalyst. In vulcanization characteristies were tested by Curastometer. The M-series vulcanizates were reached to the fastest optimum cure $time(t_{90})$ and R-series vulcanizates with the same formula had the shorted optimum cure times. Tensile characteristics measuring with a tensile tester revealed that the M-series vulcanizate was the best in the physical properties, such as tensile strength. In 100% modulus, however, the S-series vulcanizates appeared to be better than the other vulcanizates. Also, hardness showed the following order : S-series>R-series>M-series with the order of elongation R-series>M-series>S-series. In SEM test, shapes of chemical treated silicas were observed. The dispersion of filler in the SBR composite appeard uniformly. In RDS test for the dynamic characteristics, G' indicates that S-3 shows the highest value with the next order M-3>R-3, and the order of damping values are as followe: M-3>M-3>R-3.

  • PDF

히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구 (Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation)

  • 백영진;김민성;장기창;이영수;김현주
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.797-802
    • /
    • 2012
  • 본 연구에서는 두 대의 히트펌프를 이용하여 $60^{\circ}C$의 난방 공급을 하는 경우에 대하여, 병렬운전을 할 경우의 성능과 직렬운전을 할 경우의 성능을 서로 비교함으로써, 직렬운전에 의한 성능 향상 가능성을 연구하였다. 두 경우의 성능을 공정하게 비교하기 위하여, 히트펌프를 구성하는 열교환기의 전열면적을 고정하였으며, 부하측 및 열원측의 입구 유량 및 온도 조건을 고정하였다. 또한, 보다 현실적인 결과를 위하여 열교환기 내 열전달 및 압력강하 특성을 고려하였다. 시뮬레이션 결과, 직렬운전 시스템의 난방성능계수가 병렬운전 시스템의 난방성능계수에 비해 본 연구의 시뮬레이션 조건 하에서 약 5% 향상 될 수 있음을 관찰하였다.

Graphical Design Plane Analysis for Series-Compensated Resonant Energy Links of Inductive Wireless Power Transfer Systems

  • Jeong, Chae-Ho;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1440-1448
    • /
    • 2019
  • In wireless power transfer systems, it is important to design resonant energy links in order to increase the power transfer efficiency and to obtain desired system performances. This paper proposes a method for designing and analyzing the resonant energy links in a series-series configured IPT (inductive power transfer) system using the FOM-rd plane. The proposed FOM-rd graphical design plane can analyze and design the voltage gain and the power efficiency of the energy links while considering changes in the misalignment between the coils and the termination load condition. In addition, the region of the bifurcation phenomena, where voltage gain peaks are split over the frequency, can also be distinctly identified on the graphical plane. An example of the design and analysis of a 100 W inductive power transfer system with the proposed method is illustrated. The proposed method is verified by measuring the voltage gain and power efficiency of implemented hardware.

Buck-Boost Interleaved Inverter Configuration for Multiple-Load Induction Cooking Application

  • Sharath Kumar, P.;Vishwanathan, N.;Bhagwan, K. Murthy
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.271-279
    • /
    • 2015
  • Induction cooking application with multiple loads need high power inverters and appropriate control techniques. This paper proposes an inverter configuration with buck-boost converter for multiple load induction cooking application with independent control of each load. It uses one half-bridge for each load. For a given dc supply of $V_{DC}$, one more $V_{DC}$ is derived using buck-boost converter giving $2V_{DC}$ as the input to each half-bridge inverter. Series resonant loads are connected between the centre point of $2V_{DC}$ and each half-bridge. The output voltage across each load is like that of a full-bridge inverter. In the proposed configuration, half of the output power is supplied to each load directly from the source and remaining half of the output power is supplied to each load through buck-boost converter. With buck-boost converter, each half-bridge inverter output power is increased to a full-bridge inverter output power level. Each half-bridge is operated with constant and same switching frequency with asymmetrical duty cycle (ADC) control technique. By ADC, output power of each load is independently controlled. This configuration also offers reduced component count. The proposed inverter configuration is simulated and experimentally verified with two loads. Simulation and experimental results are in good agreement. This configuration can be extended to multiple loads.