• Title/Summary/Keyword: Series-Parallel

Search Result 968, Processing Time 0.034 seconds

Performance Analysis of New Working Solution for Absorption Refrigeration Machine using Treated Sewage (하수처리수이용 신용액 흡수식 냉동기의 성능해석)

  • 권오경;유선일;윤정인
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.231-240
    • /
    • 1998
  • The global environmental problems such as CFC, energy losses in heat recovery system as well as summer peak time power demands, the development of high efficiency absorption refrigeration systems is one of the most promising method in this problems. The absorption refrigeration system to utilize treated sewage is available for environmental protection and energy conservation. Simulation analysis on the double-effect absorption refrigeration cucles with parallel or series flow type has been performed. LiBr+LiI+LiCl+LiNO$_3$ solution was selected as the new working fluid. The main purpose of this study is evaluating the possibilities of effective utilization of treated sewage as a cooling water for the absorber and condenser. The other purpose of the present study is to determine the optimum designs and operating conditions based on the operating constraints and the coefficient of performance in the parallel or series flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared LiBr solution to evaluate. The absorption refrigeration machine using the new working fluid was obtained better results COP rise and compactness of system by comparison with LiBr solution.

  • PDF

Sludge Pre-Treatment by Hydrodynamic Cavitation-I: Optimization of Pre-Treatment System (수리동력학적 캐비테이션을 이용한 하수 슬러지의 전처리-I: 전처리 시스템의 최적화)

  • Maeng, Jang-Woo;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.12
    • /
    • pp.1119-1125
    • /
    • 2010
  • Most of the sludge pre-treatment methods to improve the anaerobic digestibility of sludge are not practied in the fields with low economical efficiency. The venturi cavitation system (VCS) adopting hydrodynamic cavitation is simple and requires low energy. This research was conducted to investigate the optimum design and operating conditions of the VCS. The experimental results indicated that the optimum number of venturi in series was three, and the suction mode operation of the pump yielded 1.6 times higher pre-treatment efficiency per unit energy consumption than the discharge mode. The combination of venturies with different throat sizes did not affect the pre-treatment efficiency. Also, the parallel installation of the three in series venture unit yielded 30% higher pre-treatment efficiency per unit energy consumption than the single unit. Under parallel conditions, the solubilization efficiency was 5.6 mg ${\Delta}SCOD/g$ TS/kWh, which is higher than the previously reported value.

Application of Multi-Level Inverter for Improvement of Power Quality in AC 25[kV] Electrified Railway System (교류전기철도 전력품질 향상을 위한 직.병렬 보상장치 적용에 관한 연구)

  • Park, Soo-Cheol;Song, Joong-Ho;Chang, Sang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.131-141
    • /
    • 2007
  • This paper proposes analysis on new equipment for power quality in electric railway. The proposed equipment consists of series inverter and parallel inverter. Each inverter is connected by capacitor as dc link. This structure can be compensated for active and reactive power in catenary through transformer. We verified the proposed equipment using the PSCAD/EMTDC and the calculation results from the proposed approach are widely described in the paper.

Study on the Effect of Membrane Module Configuration on Pervaporative Performance through Model Simulation (모델모사를 이용한 막모듈 연결 및 배열이 투과증발 막성능에 끼치는 영향에 관한 연구)

  • Yeom, Choong-Kyun;Yoon, Seok-Bok;Park, You-In
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.294-305
    • /
    • 2008
  • This study was focused on the investigation of the effects of membrane module configuration and the temperature of feed retentate flowing along with module length on membrane performance through model simulation. A simulation model of pervaporative dehydration through membrane module assemble in which a number of unit modules are connected in parallel or in series has been established. In this study, ethanol/water mixture was used as model mixture. Some of permeation parameters in the model were quantified directly from the real dehydration pervaporation of ethanol through a lab-made membrane. By adopting the coefficients determined empirically the simulation model could be of more practical value. The simulation of pervaporation with two basic module configurations, that is, parallel connection and series connection, could present the importance of process parameters such as feed rate, module connection mode, number of stages, and inter-stage heating.

Correlation between Reverse Voltage Characteristics and Bypass Diode Operation with Different Shading Conditions for c-Si Photovoltaic Module Package

  • Lim, Jong-Rok;Min, YongKi;Jung, Tae-Hee;Ahn, Jae-Hyun;Ahn, Hyung-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.577-584
    • /
    • 2015
  • A photovoltaic (PV) system generates electricity by installing a solar energy array; therefore, the photovoltaic system can be easily exposed to external factors, which include environmental factors such as temperature, humidity, and radiation. These factors-as well as shading, in particular-lead to power degradation. When there is an output loss in the solar cell of a PV module package, the output loss is partly controlled by the bypass diode. As solar cells become highly efficient, the characteristics of series resistance and parallel resistance improve, and the characteristics of reverse voltage change. A bypass diode is connected in parallel to the string that is connected in series to the PV module. Ideally, the bypass diode operates when the voltage is -0.6[V] around. This study examines the bypass diode operating time for different types of crystalline solar cells. It compares the reverse voltage characteristics between the single solar cell and polycrystalline solar cell. Special modules were produced for the experiment. The shading rate of the solar cell in the specially made solar energy module was raised by 5% each time to confirm that the bypass diode was operating. The operation of the bypass diode is affected not only by the reverse voltage but also by the forward bias. This tendency was verified as the number of strings increased.

Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits (전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성)

  • Hyun, Dong-Geul;Shin, Ae-Kyung
    • Journal of Science Education
    • /
    • v.38 no.2
    • /
    • pp.331-343
    • /
    • 2014
  • The types of misconceptions and their consistencies of the elementary school teachers about the characteristics of currents according to the connection methods of batteries in simple electric circuits were investigated. The misconceptions of the elementary school teachers about them could be divided into three types. Among the respondents of the 96 elementary school teachers for this study, the 2 elementary school teachers consistently understood the characteristics of currents on the basis of the misconception type of focusing only the number of batteries connected regardless of the connection methods of batteries, the 8 elementary school teachers did on the basis of the misconception type of confusing the series connection and the parallel connection of batteries, and the 4 elementary school teachers did on the basis of the misconception type of confusing the series and parallel connection of batteries with those of resistors. Also, they consistently applied these misconception types to not only the situations to use the learned concepts but the situations to use the differentiated concepts about the connection methods of batteries.

  • PDF

Design of Highly Linear Power Amplifier using Bandpass Filter based on Metamaterial Structure (Metamaterial 구조의 대역통과여파기를 이용한 WCDMA 대역 고선형 전력증폭기 설계)

  • Kim, Hyoung-Jun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.68-72
    • /
    • 2012
  • In this paper, highly linear power amplifier using bandpass filter based on metamaterial and Composite Right- / Left-Handed (CRLH) structure is proposed. The proposed bandpass filter consist of the series capacitor, series microstrip line and the parallel inductor, parallel microstrip line. The insertion loss is minimized at operation frequency and the $2^{nd}$ harmonic is suppressed by the bandpass filter using the CRLH structure. And we improved the Adjacent Channel Leakage Ratio (ACLR) using the characteristic of the proposed bandpass filter. At 2.14 GHz, we have obtained the output power of 38.83 dBm, the $2^{nd}$ harmonic of .61.33 dBc, the $3^{rd}$ IMD of .54.67 dBc, and ACLR of .51.33 dBc at 5 MHz offset, -56.50 dBc at 10 MHz offset, respectively.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

An experimental study on the operating performance of facade installed natural circulation type solar thermal system (수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구)

  • Baek, Nam-Choon;Lee, Wang-Je;Lee, Jin-Kook;Lee, Soon-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

Design of a Circular Polarization Microstrip $12\times12$ Series-Parallel Array Antenna at 10 GHz (원형 편파 마이크로스트립 $12\times12$ 직-병렬 배열 안테나 설계)

  • 이영주;정명숙;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.26-36
    • /
    • 2000
  • A circularly polarized $12\times12$ array with application in the satellite communications is designed at 10 GHz. The radiator is an aperture-coupled ring patch, which is suitable of large arrays. The element spacing of the array is chosen to be $0.7\lambda_0$to maintain the main beam in the broadside direction. The array is a sequential array constructed on a series-parallel feed network to obtain high gain and low axial ratio. Measurement results for the array, acquired by experiments in the compact range of POSTECH, showed a directivity of 27.88 dB, a high gain of 25.55 dB, an efficiency of 60%, an axial ratio of 1.74 dB, and a side-lobe level of -13 dB. The bandwidth of the array was 43% when the VSWR was 2, and the bandwidth of the axial ratio was 16%.

  • PDF