• 제목/요약/키워드: Series Reactor

검색결과 257건 처리시간 0.031초

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식 (Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Serise Active Filter)

  • 지준근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.201-203
    • /
    • 2005
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently, In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

A Three-Dimensional Calculation of the Reactor Impedance for Planar-Type Cylindrical Inductively Coupled Plasma Sources

  • Kwon, Deuk-Chul;Yoon, Nam-Sik
    • Applied Science and Convergence Technology
    • /
    • 제24권6호
    • /
    • pp.237-241
    • /
    • 2015
  • The reactor impedance is calculated for a planar-type cylindrical inductively coupled plasma source by expanding the electromagnetic fields into their Fourier-Bessel series forms including the three-dimensional shape of the antenna. The mode excitation method is utilized to determine the electromagnetic fields based on a Poynting theorem-like relationship. From the obtained electromagnetic fields, a tractable form of the reactor impedance is obtained as a function of various plasma and geometrical parameters and applied to carry out a parametric study.

유도형 고온초전도 한류기용 Prototype 직류 리액터의 설계와 제작 (Optimal Design and fabrication of Prototype DC Reactor for Inductive Superconducting fault Current Limiter)

  • 김태중;강형구;고태국
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1292-1298
    • /
    • 2003
  • In this paper, dc reactor lot the inductive high-Tc superconducting fault current limiter (SFCL) was optimally designed by finite element method(FEM). The Prototype high-Tc do reactor was manufactured and compared to the results of design. This dc reactor consists of 4∼stacked double pancake coils which are wounded with Bi-2223 wire coated with SUS315L. Kapton tape is used for the insulation of turn to turn and layer to layer. Each pancake is connected in series by soldering Finally, optimal design and manufacture method lot the dc reactor is suggested in this paper. Through the comparison of result of optimal design and experimental result of prototype high-Tc superconducting dc reactor, reliance on the design of the high-Tc dc reactor tot the 1.2 kV/80 A SFCL is proved.

Development of Acoustic Emission Monitoring System for Fault Detection of Thermal Reduction Reactor

  • Pakk, Gee-Young;Yoon, Ji-Sup;Park, Byung-Suk;Hong, Dong-Hee;Kim, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.25-34
    • /
    • 2003
  • The research on the development of the fault monitoring system for the thermal reduction reactor has been performed preliminarily in order to support the successful operation of the thermal reduction reactor. The final task of the development of the fault monitoring system is to assure the integrity of the thermal$_3$ reduction reactor by the acoustic emission (AE) method. The objectives of this paper are to identify and characterize the fault-induced signals for the discrimination of the various AE signals acquired during the reactor operation. The AE data acquisition and analysis system was constructed and applied to the fault monitoring of the small- scale reduction reactor, Through the series of experiments, the various signals such as background noise, operating signals, and fault-induced signals were measured and their characteristics were identified, which will be used in the signal discrimination for further application to full-scale thermal reduction reactor.

Thermal-hydraulic simulation and evaluation of a natural circulation thermosyphon loop for a reactor cavity cooling system of a high-temperature reactor

  • Swart, R.;Dobson, R.T.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.271-278
    • /
    • 2020
  • The investigation into a full-scale 27 m high, by 6 m wide, thermosyphon loop. The simulation model is based on a one-dimensional axially-symmetrical control volume approach, where the loop is divided into a series of discreet control volumes. The three conservation equations, namely, mass, momentum and energy, were applied to these control volumes and solved with an explicit numerical method. The flow is assumed to be quasi-static, implying that the mass-flow rate changes over time. However, at any instant in time the mass-flow rate is constant around the loop. The boussinesq approximation was invoked, and a reasonable correlation between the experimental and theoretical results was obtained. Experimental results are presented and the flow regimes of the working fluid inside the loop identified. The results indicate that a series of such thermosyphon loops can be used as a cavity cooling system and that the one-dimensional theoretical model can predict the internal temperature and mass-flow rate of the thermosyphon loop.

포화특성을 고려한 리액터의 특성 분석 (Characteristics Analysis of Reactor Considering Magnetization Saturation)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.92-98
    • /
    • 2012
  • As the increasing of non-linear load, filter is coming to be high gradually in order to reduce the harmonic which occurs from the power conversion. The maintenance of passive filter is easier than active filter and it has been widely used in the industrial site. This passive filter is connected with condenser and reactor by series and parallel and it is installed at the front of nonlinear load. The breakdown of passive filter occurs frequently at the reactor side rather than capacitor. So the breakdown cause close examination is necessary. In this paper, we analyzed that the electric stress of reactor which is considered magnetization saturation at the passive filter. We confirm that the reduction of harmonics and the electric stress of reactor is influenced by the linear and non-linear element of reactor.

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식 (Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter)

  • 지준근;김장환;설승기
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

직렬접속형 다이오드 정류기 시스템의 전류주입에 의한 고조파 저감 (Drawing Sinusoidal Input Currents of Series-Connected Diode Rectifiers by A Current Injection Technique)

  • 오준용;최세완;김영석;원충연
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.640-645
    • /
    • 1999
  • This paper proposes a new series-connected diode rectifier which draws sinusoidal input currents. The proposed rectifier system is configured by adding an auxiliary circuit to the conventional 12-pulse series-connected diode rectifier and employing a current injection technique. A low kVA($0.02P_{\circ}$(PU) ) active current source injects a triangular current into the interphase reactor of the diode rectifier. The current injection results in near sinusoidal input current from the utility with less than 1% THD. The resulting system is suitable for high voltage and high power applications. Experimental and simulation results are provided from a 220V, 3kVA prototype rectifier system.

  • PDF

A simple method for estimating the major nuclide fractional fission rates within light water and advanced gas cooled reactors

  • Mills, R.W.;Slingsby, B.M.;Coleman, J.;Collins, R.;Holt, G.;Metelko, C.;Schnellbach, Y.
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2130-2137
    • /
    • 2020
  • The standard method for calculating anti-neutrino emissions from a reactor involves knowing the fractional fission rates for the most important fissioning nuclides in the reactor. To calculate these rates requires detailed reactor physics calculations based upon the reactor design, fuel design, burnup dependent fuel composition, location of specific fuel assemblies in the core and detailed operational data from the reactor. This has only been published for a few reactors during specific time periods, whereas to be of practical use for anti-neutrino reactor monitoring it is necessary to be able to predict these on the publicly available information from any reactor, especially if using these data to subtract the anti-neutrino signal from other reactors to identify an undeclared reactor and monitor its operation. This paper proposes a method to estimate the fission fractions for a specific reactor based upon publicly available information and provides a database based upon a series of spent fuel inventory calculations using the FISPIN10 code and its associated data libraries.

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF