• Title/Summary/Keyword: Series RLC Matching

Search Result 3, Processing Time 0.018 seconds

6.2~9.7 GHz Wideband Low-Noise Amplifier Using Series RLC Input Matching and Resistive Feedback (직렬 RLC 입력 정합 및 저항 궤환 회로를 이용한 6.2~9.7 GHz 광대역 저잡음 증폭기 설계)

  • Park, Ji An;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1098-1103
    • /
    • 2013
  • A low-noise amplifier(LNA) using series RLC matching network and resistive feedback at 8 GHz is presented. Inductive degeneration is used for the input matching with which the proposed LNA shows quite a wide bandwidth in terms of $S_{21}$. An equivalent circuit model is deduced for input matching by conversion from parallel circuit to series resonant circuit. By exploiting the resistive feedback and series RLC input matching, fully integrated LNA achieves maximum $S_{21}$ of 8.5 dB(peak to -3 dB bandwidth is about 3.5 GHz) noise figure of 5.9 dB, and IIP3 of 1.6 dBm while consuming 7 mA from 1.2 V supply.

A MedRadio-Band Low Power Low Noise Amplifier for Medical Devices (의료기기용 MedRadio 대역 저전력 저잡음 증폭기)

  • Kim, Taejong;Kwon, Kuduck
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.62-66
    • /
    • 2016
  • This paper presents a MedRadio-band low power low noise amplifier for Medical Devices. A proposed MedRadio-band low power low noise amplifier adopts a current-reuse resistive feedback topology to increase overall gm and reduce power consumption. The gain of the LNA increases by the Q-factor of the additional series RLC input matching network, and its noise figure is minimized by the similar factor. Furthermore, it consumes low power because of low supply voltage and current reuse technique. By exploiting the $g_m$-booting and matching network property, the proposed MedRadio-band low noise amplifier achieves a noise figure of 0.85 dB, a voltage gain of 30 dB, and IIP3 of -7.9 dBm while consuming 0.18 mA from a 1 V supply voltage in $0.13{\mu}m$ CMOS technology.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.