• Title/Summary/Keyword: Serial discontinuity

Search Result 4, Processing Time 0.021 seconds

Spatial and Temporal Variations of δ13C and C/N in Suspended Particulate Organic Matter in the Gangneung Namdae Stream, Korea (강릉 남대천 부유입자유기물의 탄소안정동위원소 비와 C/N 비의 시·공간 변동)

  • Kwak, Jung Hyun;Park, Hyun Je
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.531-539
    • /
    • 2020
  • To understand the composition, quantity, and quality of Suspended Particulate Organic Matter (SPOM) in the Gangneung Namdae Stream, Korea, we examined spatiotemporal variations in water temperature, salinity, chlorophlly a (Chl a), Particulate Organic Carbon (POC) and nitrogen (PON), and carbon stable isotope (δ13C) of SPOM at six stations in June (pre-monsoon), July (monsoon), and September (post-monsoon) 2017. With increasing precipitation, the average POC and C/N values increased significantly in July than in June. In September, the values decreased with decreasing precipitation. The δ13C values showed irregular spatiotemporal fluctuations among the stations and periods, thereby suggesting a greater contribution of autochthonous organic matter to the pool of SPOM than that of allochthonous organic matter derived from upstream. In addition, the large and irregular changes in POC, C/N ratio, C:Chl a, and δ13C compared to that of PON were observed for all periods among the stations, indicating a serial discontinuity of the stream. Our results suggest that the Gangneung Namdae Stream is significantly influenced by the increase in freshwater discharge caused by heavy rainfalls during the summer monsoon and post-monsoon periods.

A Study of Design and Analysis on the High-Speed Serial Interface Connector (고속 직렬 인터페이스 커넥터의 설계 및 분석에 대한 연구)

  • Lee, Hosang;Shin, Jaeyoung;Choi, Daeil;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1084-1096
    • /
    • 2016
  • This paper presents method of design and analysis of a high-speed serial interface connector with a data rate of 12.5 Gbps. A high-speed serial interface connector is composed of various material and complex structures. It is very difficult to match the impedance of each discontinuous portion of connector. Therefore, this paper proposes the structure of a connector line that be simplified a connector. In the structure of proposed connector line, this research presents a method for extracting R, L, C and G parameters, analyzing the differential mode impedance, and minimizing the impedance discontinuity using time domain transmissometry and time domain reflectometry. This paper applies the proposed methods in the connector line to the high-speed serial interface connector. The proposed high-speed serial interface connector, which consists of forty-four pins, is analyzed signal transmission characteristics by changing the width and spacing of the four pins. According to the analysis result, as the width of the ground pin increases, the impedance decreases slightly. And as the distance between the ground pin and the signal pin increases, the impedance increases. In addition, as the width of the signal pin increases, the impedance decreases. And as the distance between the signal pin and the signal pin increases, the impedance decreases. The impedance characteristic of initial connector presents ranges from 96 to $139{\Omega}$. Impedance characteristic after applying the structure of proposed connector is shown as a value between 92.6 to $107.5{\Omega}$. This value satisfies the design objective $100{\Omega}{\pm}10%$.

Ultrasonographic Guidance in Acute Achilles Tendon Rupture (급성 아킬레스 건 파열에서의 초음파 이용)

  • Lee, Tae-Hoon;Lee, Hee-Dong;Kim, Hak-Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • There are many traumatic foot and ankle problems in orthopaedic fields. Though it is not life-threatening problems, a delay in accurate diagnosis and treatments can danger limb function and therefore correct diagnosis can prevent long-term complications. Achilles tendon rupture is relatively common injury for active sports people. Ultrasonography is cost-effective, irradiation -free, effective for evaluation of soft tissues and dynamic analysis. It has been growing importance in Achilles tendon rupture. Ultrasonography is a diagnostic tool in Achilles tendon rupture. Physical examination and patient history is needed to diagnose Achilles tendon without image, but it is missed up by 20% in private clinic. Discontinuity of normal fibrillar architecture seen on an ultrasonographic image is diagnostic for Achilles tendon rupture, and can be accentuated by the performance of dorsi-flexion and plantar flexion, while observing in real time. And ultrasonography is a reliable method for serial observation after surgical treatment or conservative treatment.

  • PDF

A Study on the Water Quality Relationship between Continuous Dam Discharge and Downstream in North Han River (북한강에 연속된 댐 구간 방류수와 하류 하천간 수질 관계 분석 연구)

  • Kim, Ji Won;Lee, Hye Won;Lee, Yong Seok;Choi, Jung Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.89-97
    • /
    • 2020
  • North Han River is a very unique type of water system, where Hwacheon, Chuncheon, Soyanggang, Euiam and Cheongpyeong Dams are located consecutively. These dams are operated differently in the amount of discharge and release schedule according to their structure and purpose of use. They have different water quality characteristics depending on external pollutant inflow and internal mixing condition. Therefore, this study investigated the relationship between the upper dam and down stream river with respect to water quality indicators, such as water temperature, electrical conductivity, BOD, COD, TN and TP of the North Han River. The similarities and correlations representing the relationship were analyzed by Pearson's correlation r and t-test. The data was taken from the Ministry of Environment's water quality monitoring from 1999 to 2018. The results show that water temperature and electrical conductivity of the dam and river are similar and correlated. However, it turned out that there was no similarities and correlations in BOD, COD, TN and TP that are significantly affected by subaqueous reaction mechanism. The results of this study present the impact of the dam on the water quality of North Han River, which can be used as useful data for management of water quality.