• 제목/요약/키워드: Serial Section

검색결과 60건 처리시간 0.027초

Four-channel GaAs multifunction chips with bottom RF interface for Ka-band SATCOM antennas

  • Jin-Cheol Jeong;Junhan Lim;Dong-Pil Chang
    • ETRI Journal
    • /
    • 제46권2호
    • /
    • pp.323-332
    • /
    • 2024
  • Receiver and transmitter monolithic microwave integrated circuit (MMIC) multifunction chips (MFCs) for active phased-array antennas for Ka-band satellite communication (SATCOM) terminals have been designed and fabricated using a 0.15-㎛ GaAs pseudomorphic high-electron mobility transistor (pHEMT) process. The MFCs consist of four-channel radio frequency (RF) paths and a 4:1 combiner. Each channel provides several functions such as signal amplification, 6-bit phase shifting, and 5-bit attenuation with a 44-bit serial-to-parallel converter (SPC). RF pads are implemented on the bottom side of the chip to remove the parasitic inductance induced by wire bonding. The area of the fabricated chips is 5.2 mm × 4.2 mm. The receiver chip exhibits a gain of 18 dB and a noise figure of 2.0 dB over a frequency range from 17 GHz to 21 GHz with a low direct current (DC) power of 0.36 W. The transmitter chip provides a gain of 20 dB and a 1-dB gain compression point (P1dB) of 18.4 dBm over a frequency range from 28 GHz to 31 GHz with a low DC power of 0.85 W. The P1dB can be increased to 20.6 dBm at a higher bias of +4.5 V.

연속 대절편 제작을 이용한 후두암의 병리조직학적 연구 (Histopathologic study of laryngeal cancer with serial section)

  • 이강대;이종덕;유태현
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1993년도 제27차 학술대회 초록집
    • /
    • pp.90-90
    • /
    • 1993
  • 후두암의 치료계획에 있어 어려운 점들로는 종양의 3차원적 위치, 점막하를 통한 전파, 후두연골의 침윤 여부 등이다. 특히 후두연골 침윤은 국소재발과 경부전이의 빈도가 높아 예후가 좋지 않다. 저자들은 후두암의 전파와 후두연골에의 침윤 양상을 이해하고 술전 임상적 진단의 정확도를 높여 치료방향을 설정하는데 도움을 얻고자 1991년 4월부터 1992년 11월까지 후두암으로 혹은 전적출술을 시행했던 예중 18례의 후두표본을 대상으로 연속 대절편을 제작하여 병리조직학적 관찰을 하고 다음과 같은 결과를 얻었다. 1. 후두연골 침윤의 양상은 주로 연골의 골화된 부위를 침범하였고 골화되지 않은 연골의 침윤은 매우 드물었다. 2. 침윤된 골화연골에서는 연골막이 건전하더라도 골수를 통해 전파하였다. 3. 연골막은 종양전이의 아주 강한 방어벽이었다. 4. 후두연골 침윤의 빈도는 갑상연골, 피열연골, 윤상연골, 후두개연골 순이었고 횡성문암에서는 후두연골 침윤이 88.9 % 로 상당히 높았다. 5. 후두연골 침윤여부에 대한 술전 CT의 민감도는 100%, 특이도 62.5%, 정확도 82.3%이다.

  • PDF

MIGRATION OF THE PRIMORDIAL GERM CELLS AND GONAD FORMATION IN THE EARLY CHICKEN EMBRYO

  • Hong, Y.H.;Seo, D.S.;Jeong, D.K.;Choi, K.D.;Han, J.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제8권6호
    • /
    • pp.557-562
    • /
    • 1995
  • In this study, characteristics of chick primordial germ cells (PGCs), which is the founder cell of the germline, and gonadal development of the chick embryo between 12hrs and 6 day of incubation were investigated by transverse serial sections of chick embryos under the light microscopic observation. In embryo stage 20 (3 day of incubation), there are a lot of PGCs at the mesenchym, which were moving to the thickened epithelium (gonadal ridge). The PGCs arrive at both right and left gonad primordial in equal number prior to stage 24 (4 day of incubation), but in the following stages, the distribution of the PGCs became asymmetrical. More PGCs colonized the left than the right gonad, but the reason for the unequal distribution of PGCs is uncertain. The PGCs have mostly settled in the gonadal ridge (GR) at 6 day embryo. This study was conducted to investigate characteristics of the PGC migration and gonadal formation and observe the best condition for PGC isolation, culture and to attempt the possibility of the production for transgenic germline chimeras with manipulated PGCs.

Full Wave Cockroft Walton Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.246-252
    • /
    • 2011
  • A high-voltage power supply has been built for activation of the brain via stimulation using a Full Wave Cockroft-Walton Circuit (FWCW). A resonant half-bridge inverter was applied (with half plus/half minus DC voltage) through a bidirectional power transistor to a magnetic stimulation device with the capability of producing a variety of pulse forms. The energy obtained from the previous stage runs the transformer and FW-CW, and the current pulse coming from the pulse-forming circuit is transmitted to a stimulation coil device. In addition, the residual energy in each circuit will again generate stimulation pulses through the transformer. In particular, the bidirectional device modifies the control mode of the stimulation coil to which the current that exceeds the rated current is applied, consequently controlling the output voltage as a constant current mode. Since a serial resonant half-bridge has less switching loss and is able to reduce parasitic capacitance, a device, which can simultaneously change the charging voltage of the energy-storage condenser and the pulse repetition rate, could be implemented. Image processing of the brain activity was implemented using a graphical user interface (GUI) through a data mining technique (data mining) after measuring the vital signs separated from the frequencies of EEG and ECG spectra obtained from the pulse stimulation using a 90S8535 chip (AMTEL Corporation).

하치조신경 절단 후 흰쥐 삼차신경절에서 VIP-IR의 변화 (VIP IMMUNOREACTIVITY IN THE RAT TRIGEMINAL GANGLION AFTER INFERIOR ALVEOLAR NERVE AXOTOMY)

  • 김흥중;박주철;김현섭;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.225-234
    • /
    • 2000
  • The purpose of this study was to investigate the distribution and fluorescene intensity of vasoactive intestinal polypeptide(VIP) immunoreactive cells in rat trigeminal ganglion after inferior alveolar nerve axotomy. The animals were divided into normal and two experimental groups. The experimental animals were sacrificed at 14th and 28th day after inferior alveolar nerve axotomy. The trigeminal ganglion was removed and immersed in the 4% paraformaldehyde-0.2% picric acid in 0.1M phosphate buffer. Serial frozon sections about $16{\mu}m$ in thickness were cut with a cryostat. The immunofluorescence staining was performed. The rabbit anti-VIP(1 : 8,000) was used as primary antibody and fluorescene isothiocynate(FITC)-conjugated anti-rabbit IgG(1 : 80) as secondary antibody. The slides were observed under confocal laser scanning microscope. Three-dimensional images were constructed from 9 serial images(each $1{\mu}m$ in thickness) made by automatic optical sectioning. Unprocessed optical sections were obtained and stored on a optical disk. Color picture were printed by a video copy processor. The results were as follows; 1. The appearance of VIP immunoreactive cells in the mandibular part of trigeminal ganglion was 8.79${\pm}$1.99% in normal group and 39.16${\pm}$5.62% in 14 days, 16.25${\pm}$2.39% in 28 days after inferior alveolar nerve axotomy groups. 2. The relative fluorescence intensity of VIP immunoreactive cell bodies in the mandibular part of trigeminal ganglion was 134.40${\pm}$10.39 in normal group and 192.88${\pm}$14.06 in 14 days, 143.10${\pm}$5.02 in 28 days after nerve axotomy groups. Therefore, the relative fluorescence intensity of 14 days after nerve axotomy group was 43.3% higher than intensity of normal group. 3. In optical single section analysis of VIP immunoreactive cell bodies, white cell bodies(moderate fluorescence intensity) were the most abundant in normal and 28 days after nerve axotomy groups. Whereas, in 14 days after nerve axotomy group, red cell bodies(high fluorescence intensity) were the most abundant. 4. In optical serial section analysis of VIP immunoreactive cell bodies, red cell bodies(high fluorescence intensity) were observed in a part of the 9 sections of normal and 24 days after nerve axotomy groups. Whereas, red cell bodies were observed in all of the 9 sections of 14 days after nerve axotomy group. 5. The results indicates that number and fluorescence intensity of VIP immunoreactive cells were increased in the mandibular part of trigeminal ganglion following inferior alveolar nerve axotomy.

  • PDF

EMS/SCADA의 DNP3 연계구간 보안성 평가·인증 기술 연구 (A Study of Security Certification and Accreditation for DNP3 linkage section in EMS/SCADA)

  • 김종완;손태식
    • 정보보호학회논문지
    • /
    • 제25권3호
    • /
    • pp.703-713
    • /
    • 2015
  • 기존의 EMS/SCADA에서 제어시스템과 필드디바이스 간의 연계시스템은 데이터의 신뢰성을 높이기 위해서 외부 네트워크와의 망 분리를 통한 접근 통제를 하였지만 현재는 운영의 효율성 증대와 체계적 관리, 경제적 측면을 고려한 외부 망과의 연결 필요성이 증가하고 있는 추세이다. 이런 발전한 연계구간은 과거에 비해 더 많은 보안 취약점을 갖게 되었으며, EMS/SCADA 연계구간에서의 통신은 특별한 관리 방법이 필요하다. 본 논문에서는 국내 환경을 고려하여 EMS/SCADA 연계구간에서 주로 사용되는 시리얼 DNP3와 TCP/IP기반 DNP3를 적용한 보안성 평가 인증기술을 제시하였다. 제시하는 보안성 평가 인증기술은 자원 안전성 테스트와 악성 패킷 테스트 2가지 세부 평가로 나누어 안전성을 평가하며 각각의 보안 요구사항 및 평가방법을 도출하여 기존의 평가 인증 기술들과의 차별성을 제시하고자 하였다.

교차 자속을 이용한 새로운 플라이백 컨버터 (A New Flyback Converter Using the Cross Flux of Transformer)

  • 구복재;김효선;박성준;박성미
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.73-82
    • /
    • 2014
  • This research proposes a new type of flyback converter topology based on magnetic circuit sharing. The proposed flyback topology uses a transformer involving shared magnetic flux, and its characteristic is magnetic flux cancelation by cross magnetic flux in the magnetic flux-sharing part of the core. The new topology aims to reduce the volume of transformer by reducing the cross section of the core. Compared to conventional converters using only 1 transformer, its circuit configuration involving the serial input and parallel output of 2 flyback coils allowed increased converter insulation strength. In addition, the adoption of interleaved switching method achieved the improvement of output voltage ripple, while magnetic circuit sharing reduced by 50% the cross section of core where magnetic circuit was shared.

크랙을 가진 단순지지 보의 동특성에 미치는 이동질량의 영향 (Influence of Serial Moving Masses on Dynamic Behavior of Simply Supported Beam with Crack)

  • 윤한익;김영수;손인수
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.555-561
    • /
    • 2003
  • An iterative modal analysis approach is developed to determine the effect of transverse open cracks on the dynamic behavior of simply supported Euler-Bernoulli beams with the moving masses. The influences of the velocities of moving masses, the distance between the moving masses and a crack have been studied on the dynamic behavior of a simply supported beam system by numerical method. The Presence of crack results In large deflection of beam. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments i.e. the crack is modelled as a rotational spring. This flexibility matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. Totally, as the velocity of the moving masses and the distance between the moving masses are increased, the mid-span deflection of simply supported beam with the crack is decreased.

크랙을 가진 단순지지 보의 동특성에 미치는 이동질량의 영향 (Influence of Serial Moving Masses on Dynamic Behavior of a Simply Support Beam with Crack)

  • 손인수;조정래;윤한익
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1085-1090
    • /
    • 2003
  • An iterative modal analysis approach is developed to determine the effect of transverse open cracks on the dynamic behavior of simply supported Euler-Bernoulli beams with the moving masses. The influences of the velocities of moving masses, the distance between the moving masses and a crack have been studied on the dynamic behavior or a simply supported beam system by numerical method. no presence or crack results in large deflection of beam. The crack section is represented by a local flexibility matrix connecting two undamaged beam segments i.e. the crack is modelled as a rotational spring. This flexibility matrix defines the relationship between the displacements and forces across the crack section and is derived by applying fundamental fracture mechanics theory. Totally, as the velocity of the moving masses and the distance between the moving masses are increased, the mid-span deflection of simply supported beam with the crack is decreased.

  • PDF

Internet-Based Control and Monitoring System Using LonWorks Fieldbus for HVAC Application

  • Hong, Won-Pyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1205-1210
    • /
    • 2004
  • The 4-20mA analog signal used in the various industrial fields to interface sensor in distributed process control has been replaced with relatively simple digital networks, called "fieldbus, and recently by Ethernet. Significant advances in Internet and computer technology have made it possible to develop an Internet based control, monitoring, and operation scheduling system for heating, ventilation and air-conditioning (HVAC) systems. The seamless integration of data networks with control networks allows access to any control point from anywhere. Field compatible field devices become so-called "smart" devices, capable of executing simple control, diagnostic and maintenance functions and providing bidirectional serial communication to higher level controller. The most important HVAC of BAS has received nationwide attention because of higher portion of more than 40% in building sector energy use and limited resources. This paper presents the Internet-based monitoring and control architecture and development of LonWorks control modules for AHU (air handling units) of HVAC in viewpoint of configuring BAS network. This article addresses issues in architecture section, electronics, embedded processors and software, and internet technologies.

  • PDF