• Title/Summary/Keyword: Sequence Design

Search Result 1,505, Processing Time 0.036 seconds

Bioequivalence of AmbrectTM Tablet to MucopectTM Tablet (Ambroxol hydrochloride 30 mg) (뮤코펙트 정(염산암브록솔 30 mg)에 대한 암브렉트 정의 생물학적 동등성)

  • Yoo, Jeong-Yeon;Joung, Sun-Koung;Choi, Mee-Hee;Han, Sang-Beom;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.3
    • /
    • pp.215-221
    • /
    • 2003
  • A bioequivalence study of $Ambrect^{TM}$ tablets (Dong Wha Pharm. Ind. Co., Ltd.) to $Mucopect^{TM}$ tablets (Boehringer Ingelheim Korea, Ltd.) was conducted according to the guideline of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korea volunteers received each medicine at the ambroxol hydrochloride dose of 30 mg in a $2{\times}2$ crossover study. There was a one-week wash out period between the doses. Plasma concentrations of ambroxol were monitored by a high-performance liquid chromatography for over a period of 24 hours after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calulated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}\;(time\;to\;reach\;C_{max})$ were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Ambrect^{TM}/Mucopect^{TM}$ were 0.89-1.01 and 0.89-1.02, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Ambrect^{TM}\;and\;Mucopect^{TM}$ with respect to the rate and extent of absorption.

ARQ Packet Error Control Scheme Using Multiple Threads Based on MMT Protocol (MMT 프로토콜 기반의 다중쓰레드를 활용한 ARQ 패킷 오류 제어 기법)

  • Won, Kwang-eun;Ahn, Eun-bin;Kim, Ayoung;Lee, Hong-rae;Seo, Kwang-deok
    • Journal of Broadcast Engineering
    • /
    • v.23 no.5
    • /
    • pp.682-692
    • /
    • 2018
  • In this paper, we propose an ARQ packet error control scheme using multiple threads in delivering massive capacity of multimedia based on MMT(MPEG Media Transport) protocol. On the sending side, each frame that constitutes an image is packetized into MMT packets based on MMT protocol. The header of the packet stores the sequence number of the frames contained in the packet and the time of presentation information. The payload of the packet stores the direct information that comprises the frame. The generated MMT packet is transmitted to the IP network. The receiving side checks if any error has occurred in the received packet. For any identified error, it controls the error through ARQ error control scheme and reconfigure the frame according to the information stored in the header of the received packet. At this point, a multi-threading based transport design is constructed so that each thread takes over a single frame, which increases the transmission efficiency of massive capacity multimedia. The efficiency of the multi-threading transport method is verified by solving the problems that might arise when using a single-thread approach if packets with errors are retransmitted.

Bioavailability of Cefaclor Capsules Using an Improved Analytical Method of Cefaclor in Human Plasma (개선된 사람 혈장중 세파클러 농도 정량법을 이용한 세파클러 캡슐의 생체이용률 측정)

  • Kim, Tae-Wan;Song, Ok-Kyoung;Han, Sun-Young;Cao, Qing-Ri;Park, Mi-Jin;Kang, Sung-Ha;Shin, Kwan-Seog;Cui, Jing-Hao;Lee, Beom-Jin
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • After establishing improved HPLC analytical method of cefaclor in human plasma samples, a bioavailability study of cefaclor capsules was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). The standard calibration curve using an HPLC with UV detector was constructed in a range of $0.0324{\sim}16\;{\mu}g/ml$. The 6% perchloric acid instead of 6% trichloroacetic acid was used to precipitate plasma protein. The HPLC chromatograms were precisely and accurately resolved when spiked with human plasma spiked with cefaclor and cephalexin (internal standard). Twenty healthy male Korean volunteers received two commercial cefaclor capsules, $Neocef^{\circledR}$ capsule (Jinyang Pharm. Co., Ltd) or $Ceclor^{\circledR}$ capsule (Lilly Korea. Co., Ltd.) at the 250 mg cefaclor in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of cefaclor were monitored for 8 hours after oral drug administration. $AUC_t$ the area under the plasma concentration-time curve from time zero to 8 hr (13 points), was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the cross-over design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Neocef^{\circledR}/Ceclor^{\circledR}$ were $0.9049{\leq}{\delta}{\leq}1.226$, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Neocef^{\circledR}/Ceclor^{\circledR}$ with respect to the extent of absorption.

Bioequivalence of DilastTM Capsule to Ketas® Capsule (Ibudilast 10 mg) (케타스캅셀(이부딜라스트 10 mg)에 대한 딜라스트캡슐의 생물학적동등성)

  • Chang, Kyu-Young;Kang, Seong-Woo;Yoo, Eun-Ju;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.197-203
    • /
    • 2007
  • A bioequivalence study of $Dilast^{TM}$ Capsule (Chong Kun Dang Pharma. Co., Ltd.) to $Ketas^{(R)}$ Capsule (Han Dok Pharma. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty eight healthy male Korean volunteers received each medicine at the ibudilast dose of 20 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of ibudilast were monitored by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) for over a period of 36 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 36 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Dilast^{TM}$ $Capsule/Ketas^{(R)}$ Capsule were $log0.93{\sim}log1.06$ and $log0.93{\sim}log1.11$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Dilast^{TM}$ Capsule and $Ketas^{(R)}$ Capsule with respect to the rate and extent of absorption.

Development of App. for Visualization of Micro Hydro Power Potential (초소수력 발전 잠재량의 가시화를 위한 앱 개발)

  • Kim, Dong Hyun;Yang, Chang Wook;Lee, Seung Oh
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • Interest in all kinds of renewable energies has been highly increased while the micro-small-hydro power(MSHP) development has shown relatively slowly growth because of the negative public recognition about dam site development. It is, however, announced that the micro-SHP shows higher energy conversion efficiency compared to other renewable energies and does not emit any carbon dioxide. Thus, it is concerned about the development and application of micro-SHP as an alternative energy. In this study, the application for Android was exploited with Eclipse to visualize readily the potential realizable amount of hydropower by micro-SHP. With this application, we can select the region from the map, obtain the design discharge of the selected site was calculated with HEC-HMS, presented by U.S. Army of Corp. and perform the simply economic analysis in sequence. Yeongwol in Gangwon-do Province, Korea was chosen as the target area since historically abundant precipitation was found and it is possible to obtain fundamental data from WAMIS. Results from this study could be expanded the whole region of Korea. Also, the initial investment cost would be reduced if the location for micro-SHP would be determined properly, because this application can help us easily select and examine the potential micro-SHP sites without on-the-spot visit.

Bioequivalence of FLUTAL Tablet to SOMALGEN Tablet (Talniflumate 370 mg) (소말겐 정(탈니플루메이트 370 mg)에 대한 플루탈 정의 생물학적동등성)

  • Lee, Heon-Woo;Cho, Sung-Hee;Park, Wan-Su;Im, Ho-Taek;Kim, Young-Kwan;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.303-308
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two talniflumate tablets, SOMALGEN tablet (Kun Wha Pharm. Co., Ltd., Seoul, Korea, reference drug) and FLUTAL tablet (Kukje Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the talniflumate dose of 740 mg in a $2{\pm}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of niflumic acid were monitored by an HPLC-UV for over a period of 14 hr after the administration. $AUC_t$(the area under the plasma concentration-time curve from time zero to 14 hr) was calculated by the linear trapezoidal rule method. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$, ratio and the $C_{max}$ ratio for SOMALGEN/FLUTAL were $log0.8510{\sim}log1.0318$ and $log0.9264{\sim}log1.0607$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Taken together, our study demonstrated the bioequivalence of SOMALGEN and FLUTAL with respect to the rate and extent of absorption.

Bioequivalence Of SudoTM Ranitidine Hydrochloride Tablet to CuranTM Tablet (Ranitidine Hydrochloride 150 mg) (큐란 정(염산라니티딘 150 mg)에 대한 수도염산라니티딘정의 생물학적동등성)

  • Lee, Sun-Neo;Ko, Youn-Jung;Kang, Seung-Woo;Yoon, Seo-Hyun;Park, Moo-Sin;Lee, Ye-Ri;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.193-199
    • /
    • 2006
  • A bioequivalence study of $Sudo^{TM}$ Ranitidine HCI tablet (Sudo Pharma. Ind. Co., Ltd.) to $Curan^{TM}$ tablet (Il Dong Pharma. Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the ranitidine hydrochloride dose of 150 mg in a 2x2 crossover study. There was a one week wash-out period between the doses. Plasma concentrations of ranitidine were monitored by a high-turbulent liquid chromatography (HTLC) for over a period of 12 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found far all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Sudo^{TM}$ Ranitidine $HCl/Curan^{TM}$ were 0.92-1.00 and 0.90-1.03, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Sudo^{TM}$ Ranitidine HCI and $Curan^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of Thioct Acid HR Tablet to Daewon Thioctic Acid HR Tablet 600 mg(Thioctic Acid 600 mg) (치옥타시드 에이취알 정(치옥트산 600 mg)에 대한 대원치옥트산 에이취알 정 600 mg의 생물학적 동등성)

  • Kang, Il-Mo;Lee, Heon-Woo;Lee, Hyun-Soo;Seo, Ji-Hyung;Ryu, Ju-Hee;Kim, Yong-Won;Kim, Sung-Su;Cho, Sung-Hee;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.6
    • /
    • pp.413-419
    • /
    • 2006
  • In this study, the main purpose was to evaluate the bioequivalence of two thioctic acid tablests, Thioctacid HR tablet(Bukwang Pharm. Co., Ltd.) and Daewon thioctic acid HR tablet 600 mg(Daewon Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration(KFDA). Twenty-four, healthy Korean volunteers were divided into two groups, randomized and treated by $2{\times}2$ crossover study. After the administration of one thioctic acid tablet containing 600 mg thioctic acid, blood samples were taken until 8 hr after the oral administration. LC-MS/MS was applied to determination of thioctic acid, and we calculated the $AUC_t,\;C_{max},\;T_{max}$ from the plasma concentration-time data. Analysis of variance(ANOVA) was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Daewon thioctic acid tablet 600 mg/Thioctacid HR were log 0.9877$\sim$log 1.1938 and log 0.8169$\sim$log 1.2237, respectively. These values were within the acceptable bioequivalence intervals of log 0.80$\sim$log 1.25, recommended by KFDA. In all of these results we concluded that Daewon thioctic acid tablet 600 mg was bioequivalent to Thioctacid HR tablet, in terms of rate and extent of absorption.

Bioequivalence of MelaxTM Capsule to MobicTM Capsule (Meloxicam 7.5 mg) (모빅 캡슐(멜록시캄 7.5 mg)에 대한 멜락스 캡슐의 생물학적동등성)

  • Lee, Ye-Rie;Yeom, Seung-Bock;Ko, Youn-Jung;Ko, Jung-Kil;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.413-418
    • /
    • 2004
  • A bioequivalence of $Melax^{TM}$ capsules (Chong Kun Dang Pharm., Korea) and $Mobic^{TM}$ capsules (Boehringer Ingelheim Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 15 mg dose of meloxicam of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2\;{\times}\;2$ crossover design. Concentrations of meloxicam in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 72 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Melax^{TM}/Mobic^{TM}$ were 0.95 - 1.04 and 0.98 - 1.14, respectively. This study demonstrated a bioequivalence of $Melax^{TM}$ and $Mobic^{TM}$ with respect to the rate and extent of absorption.

A Design and Implementation of the Management Sever for the Gateway Supporting Home Networking Using the UML (UML을 이용한 흠 네트워킹 지원 게이트웨이 관리 서버 설계 및 구현)

  • 권진혁;민병조;강명석;남의석;김학배
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.3
    • /
    • pp.393-404
    • /
    • 2004
  • Recently, public home have used a more than two computer connected with network, and several home appliances using independently with internet or network are developing to be related closely with the network. Therefore, the home utilized for a simple terminal of the global network in the past is being expanded to another part of the sub network. For a variety of connecting home-area protocols with the existing existing network, we require a new Residential Gateway(RG) that does not only make the home-area network operating in the sub network but also connects to the external network. In this paper, RG has intrinsic limits against flexible service due to IP address assignment and hardware capacity. In order to solve this problem in the RG, we propose a Management Server(MS). The MS that offers the integrated managements and control services for a variety of devices connected the RG in the home-area. It can not only solve the dynamic IP address assigning problem but also assigns private IP addresses to the home network devices through the Network Address Translation(NAT). It also provides somewhat useful functions for the home network and the RG for other additional services. <중략> The MS is using a SNMP protocol for managing the RG in the domain, a polling method of the MS and the RG compose a sequence polling method, a polling method using a multi-process and a multi-thread. In this paper, we introduce a problem with polling method separately, show a polling method between the MS and the RG using a multi-thread.

  • PDF