• 제목/요약/키워드: Separation of periodic

Search Result 66, Processing Time 0.02 seconds

Thermal Behavior of Energy Pile Considering Ground Thermal Conductivity and Thermal Interference Between Piles (주변 지반의 열전도도를 고려한 PHC 에너지파일의 열 거동 및 파일 간 열 간섭 현상에 대한 수치해석 연구)

  • Go, Gyu Hyun;Yoon, Seok;Park, Do Won;Lee, Seung-Rae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2381-2391
    • /
    • 2013
  • In general, ground's thermal properties, types of heat exchanger, operational method, thermal interference between piles can be considered as key factors which affect the thermal performance of energy pile. This study focused on the effect of these factors on the performance by a numerical model reflecting a real ground condition. Depending on the degree of saturation of ground, pile's heat transfer rate showed a maximum difference of three times, and the thermal resistance of pile made a maximum difference of 8.7%. As for the type of heat exchanger effects on thermal performance, thermal efficiency of 3U type energy pile had a higher value than those of W and U types. The periodic operation (8 hours operation, 16 hours pause) can preserve about 20% of heat efficiency compared to continuous operation, and hence it has an advantage of preventing the thermal accumulation phenomenon. Thermal interference effect in group piles may vary depending on the ground condition because the extent decreases as the ground condition varies from saturated to dry. The optimal separation distance that maintains the decreasing rate of heat efficiency less than 1% was suggested as 3.2D in U type, 3.6D in W type, and 3.7D in 3U type in a general ground condition.

Three-dimensional Digital Restoration and Surface Depth Modeling for Shape Analysis of Stone Cultural Heritage: Haeundae Stone Inscription (석조문화유산의 형상분석을 위한 3차원 디지털복원과 표면심도 모델링:해운대 석각을 중심으로)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.28 no.1
    • /
    • pp.87-94
    • /
    • 2012
  • This study was focused on digital restoration and surface depth modeling applying the three-dimensional laser scanning system of the Haeundae Stone Inscription. Firstly, the three-dimensional digital restoration carried out acquiring of point cloud using wide range and precision scanner, thereafter registering, merging, filtering, polygon mesh and surveyed map drawing. In particular, stroke of letters, inscribed depth and definition appearing the precision scanning polygon was outstanding compared with ones of the wide range polygon. The surface depth modeling completed through separation from polygon, establishment of datum axis, selection of datum point, contour mapping and polygon merging. Also, relative inscribed depth (5~17mm) and outline by the depth modeling was well-defined compared with photograph and polygon image of the inscription stone. The digital restoration technology merging wide range and precision scanning restored the total and detailed shape of the Stone Inscription quickly and accurately. In addition, the surface depth modeling visibly showed unclear parts from naked eye and photograph. In the future, various deteriorations and surrounding environment change of the Stone Inscription will be numerically analyze by periodic monitoring.

Improved Organic Removal Efficiency in Two-phase Anaerobic Reactor with Submerged Microfiltration System (침지형 정밀여과시스템을 결합한 이상 혐기성 시스템에 의한 유기물 제거율의 향상)

  • Jung, Jin-Young;Chung, Yun-Chul;Lee, Sang-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.629-637
    • /
    • 2000
  • A two-phase anaerobic reactor with a submerged microfiltration system was tested for its ability to produce methane energy from organic wastewater. A membrane separation system with periodic backwashing with compressed air was submerged in the acidogenic reactor. The cartridge type of microfiltration (MF) membrane with pore size of $0.5{\mu}m$ (mixed esters of cellulose) was tested. An AUBF (Anaerobic Upflow Sludge Bed Filter: 1/2 packed with plastic media) was used for the methanogenic reactor. Soluble starch was used as a substrate. The COD removal was investigated for various organic loading with synthetic wastewater of 5,000 mg starch/L. When the hydraulic retention time (HRT) of the acidogenic reactor was changed from 10 to 4.5 days, the organic loading rate (OLR) varied from 0.5 to $1.0kg\;COD/m^3-day$. When the HRT of the methanogenic reactor was changed from 2.8 to 0.5 days, the OLR varied from 0.8 to $5.8kg\;COD/m^3-day$. The acid conversion rate of the acidogenic reactor was over 80% in the 4~5 days of HRT. The overall COD removal efficiency of the methanogenic reactor showed over 95% (effluent COD was below 300 mg/L) under the highly fluctuating organic loading condition. A two-phase anaerobic reactor showed an excellent acid conversion rate from organic wastewater due to the higher biomass concentration than the conventional system. A methanogenic reactor combined with sludge bed and filter, showed an efficient COD and SS removal.

  • PDF

A Study on Cross-correlation Control Schemes on Walsh and Golay Codes Based on the Orthogonal Transformation and BER Performance Evaluation of Asynchronous CDMA System Using the Modified Codes (직교변환에 의한 Walsh 및 Golay 코드의 상호상관 제어방식과 수정된 코드를 사용한 비동기 CDMA 시스템의 비트오율 성능에 관한 연구)

  • Lee, Won-Chang;Kim, Myoung-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.304-312
    • /
    • 2008
  • Orthogonal codes like Walsh and Golay codes may have large correlation value when they are not synchronized, hence they are seldom used in asynchronous CDMA systems. Wysocki[1] showed that by multiplying the original Walsh-Hadamard matrix with an orthogonal transformation matrix the resultant matrix sustains orthogonality between row vectors and their cross-correlation can be reduced. Soberly and Wysocki[2] proposed similar scheme on Golay codes. This implies that using the proper orthogonal transformation cross-correlation of Walsh and Golay codes can be reduced, and the transformed codes can be used for user separation in the CDAM reverse link. In this paper we discuss cross-correlation related parameters which affect the performance of an asynchronous CDMA link, and we investigate the correlation properties of the transformed codes. When we designed orthogonal transformation matrices for Walsh and Golay codes, we minimized the maximum value of aperiodic cross-correlation of the codes ($ACC_{max}$) or the mean square value of the aperiodic cross-correlation($R_{cc}$) with preserving the orthogonality of the modified codes. We also evaluate the asynchronous CDMA system that uses the transformed Walsh and Golay codes.

  • PDF

Reviews on Post-synthetic Modification of Metal-Organic Frameworks Membranes (다결정 금속 유기 골격체 분리막의 후처리 성능 제어기술 개발 동향)

  • Hyuk Taek, Kwon;Kiwon, Eum
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.367-382
    • /
    • 2022
  • Numerous metal-organic frameworks (MOFs) produced by periodic combinations of organic ligands and metal ions or metal-oxo clusters have led the way for the creation of energy-efficient membrane-based separations that may serve as viable replacements for traditional thermal counterparts. Although tremendous progress has been made over the past decade in the synthesis of polycrystalline MOF membranes, only a small number of MOFs have been exploited in the relevant research. Intercrystalline defects, or nonselective diffusion routes in polycrystalline membranes, are likely the reason behind the delay. Postsynthetic modifications (PSMs) are newly emerging strategies for providing polycrystalline MOF membrane diversity by leveraging advanced membranes as a platform and improving their separation capabilities via physical and/or chemical treatments; therefore, neither designing and developing MOFs nor tailoring membrane synthesis techniques for focused MOFs is necessary. In this minireview, seven subclasses of PSM techniques that have recently been adapted to polycrystalline MOF membranes are outlined, along with obstacles and future directions.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.